Literature DB >> 28574345

Noncontact 3-D Speckle Contrast Diffuse Correlation Tomography of Tissue Blood Flow Distribution.

Chong Huang, Daniel Irwin, Mingjun Zhao, Yu Shang, Nneamaka Agochukwu, Lesley Wong, Guoqiang Yu.   

Abstract

Recent advancements in near-infrared diffuse correlation techniques and instrumentation have opened the path for versatile deep tissue microvasculature blood flow imaging systems. Despite this progress there remains a need for a completely noncontact, noninvasive device with high translatability from small/testing (animal) to large/target (human) subjects with trivial application on both. Accordingly, we discuss our newly developed setup which meets this demand, termed noncontact speckle contrast diffuse correlation tomography (nc_scDCT). The nc_scDCT provides fast, continuous, portable, noninvasive, and inexpensive acquisition of 3-D tomographic deep (up to 10 mm) tissue blood flow distributions with straightforward design and customization. The features presented include a finite-element-method implementation for incorporating complex tissue boundaries, fully noncontact hardware for avoiding tissue compression and interactions, rapid data collection with a diffuse speckle contrast method, reflectance-based design promoting experimental translation, extensibility to related techniques, and robust adjustable source and detector patterns and density for high resolution measurement with flexible regions of interest enabling unique application-specific setups. Validation is shown in the detection and characterization of both high and low contrasts in flow relative to the background using tissue phantoms with a pump-connected tube (high) and phantom spheres (low). Furthermore, in vivo validation of extracting spatiotemporal 3-D blood flow distributions and hyperemic response during forearm cuff occlusion is demonstrated. Finally, the success of instrument feasibility in clinical use is examined through the intraoperative imaging of mastectomy skin flap.

Entities:  

Mesh:

Year:  2017        PMID: 28574345      PMCID: PMC5645791          DOI: 10.1109/TMI.2017.2708661

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  22 in total

1.  Scattering and Imaging with Diffusing Temporal Field Correlations.

Authors: 
Journal:  Phys Rev Lett       Date:  1995-08-28       Impact factor: 9.161

2.  Noncontact diffuse correlation spectroscopy for noninvasive deep tissue blood flow measurement.

Authors:  Yu Lin; Lian He; Yu Shang; Guoqiang Yu
Journal:  J Biomed Opt       Date:  2012-01       Impact factor: 3.170

3.  Fast and efficient image reconstruction for high density diffuse optical imaging of the human brain.

Authors:  Xue Wu; Adam T Eggebrecht; Silvina L Ferradal; Joseph P Culver; Hamid Dehghani
Journal:  Biomed Opt Express       Date:  2015-10-26       Impact factor: 3.732

4.  Simultaneous blood flow and blood oxygenation measurements using a combination of diffuse speckle contrast analysis and near-infrared spectroscopy.

Authors:  Myeongsu Seong; Zephaniah Phillips; Phuong Minh Mai; Chaebeom Yeo; Cheol Song; Kijoon Lee; Jae Gwan Kim
Journal:  J Biomed Opt       Date:  2016-02       Impact factor: 3.170

5.  Determination of optimal exposure time for imaging of blood flow changes with laser speckle contrast imaging.

Authors:  Shuai Yuan; Anna Devor; David A Boas; Andrew K Dunn
Journal:  Appl Opt       Date:  2005-04-01       Impact factor: 1.980

6.  Statistics of local speckle contrast.

Authors:  Donald D Duncan; Sean J Kirkpatrick; Ruikang K Wang
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2008-01       Impact factor: 2.129

7.  Smear correction for frame transfer charge-coupled-device cameras.

Authors:  W Ruyten
Journal:  Opt Lett       Date:  1999-07-01       Impact factor: 3.776

8.  Deep tissue flowmetry based on diffuse speckle contrast analysis.

Authors:  Renzhe Bi; Jing Dong; Kijoon Lee
Journal:  Opt Lett       Date:  2013-05-01       Impact factor: 3.776

9.  Speckle contrast optical tomography: A new method for deep tissue three-dimensional tomography of blood flow.

Authors:  Hari M Varma; Claudia P Valdes; Anna K Kristoffersen; Joseph P Culver; Turgut Durduran
Journal:  Biomed Opt Express       Date:  2014-03-28       Impact factor: 3.732

10.  Influences of tissue absorption and scattering on diffuse correlation spectroscopy blood flow measurements.

Authors:  Daniel Irwin; Lixin Dong; Yu Shang; Ran Cheng; Mahesh Kudrimoti; Scott D Stevens; Guoqiang Yu
Journal:  Biomed Opt Express       Date:  2011-06-17       Impact factor: 3.732

View more
  12 in total

1.  The Role of Intraoperative Laser Speckle Imaging in Reducing Postoperative Complications in Breast Reconstruction.

Authors:  Alisha Bonaroti; Ryan C DeCoster; Siavash Mazdeyasna; Chong Huang; Guoqiang Yu; Lesley Wong
Journal:  Plast Reconstr Surg       Date:  2019-11       Impact factor: 4.730

2.  Noncontact speckle contrast diffuse correlation tomography of blood flow distributions in tissues with arbitrary geometries.

Authors:  Siavash Mazdeyasna; Chong Huang; Mingjun Zhao; Nneamaka B Agochukwu; Ahmed A Bahrani; Lesley Wong; Guoqiang Yu
Journal:  J Biomed Opt       Date:  2018-09       Impact factor: 3.170

3.  A Wearable Fiberless Optical Sensor for Continuous Monitoring of Cerebral Blood Flow in Mice.

Authors:  Chong Huang; Yutong Gu; Jing Chen; Ahmed A Bahrani; Elie G Abu Jawdeh; Henrietta S Bada; Kathryn Saatman; Guoqiang Yu; Lei Chen
Journal:  IEEE J Sel Top Quantum Electron       Date:  2018-07-09       Impact factor: 4.544

4.  Recovery of the diffuse correlation spectroscopy data-type from speckle contrast measurements: towards low-cost, deep-tissue blood flow measurements.

Authors:  K Murali; A K Nandakumaran; Turgut Durduran; Hari M Varma
Journal:  Biomed Opt Express       Date:  2019-09-30       Impact factor: 3.732

5.  Noncontact Speckle Contrast Diffuse Correlation Tomography of Blood Flow Distributions in Burn Wounds: A Preliminary Study.

Authors:  Mingjun Zhao; Siavash Mazdeyasna; Chong Huang; Nneamaka Agochukwu-Nwubah; Alisha Bonaroti; Lesley Wong; Guoqiang Yu
Journal:  Mil Med       Date:  2020-01-07       Impact factor: 1.437

6.  High-density speckle contrast optical tomography of cerebral blood flow response to functional stimuli in the rodent brain.

Authors:  Tanja Dragojević; Ernesto E Vidal Rosas; Joseph L Hollmann; Joseph P Culver; Carles Justicia; Turgut Durduran
Journal:  Neurophotonics       Date:  2019-10-08       Impact factor: 3.593

7.  Speckle contrast diffuse correlation tomography of cerebral blood flow in perinatal disease model of neonatal piglets.

Authors:  Chong Huang; Siavash Mazdeyasna; Mehrana Mohtasebi; Kathryn E Saatman; Qiang Cheng; Guoqiang Yu; Lei Chen
Journal:  J Biophotonics       Date:  2021-01-03       Impact factor: 3.207

8.  Noncontact optical imaging of brain hemodynamics in preterm infants: a preliminary study.

Authors:  Elie G Abu Jawdeh; Chong Huang; Siavash Mazdeyasna; Lei Chen; Li Chen; Henrietta S Bada; Guoqiang Yu
Journal:  Phys Med Biol       Date:  2020-12-22       Impact factor: 3.609

9.  Extraction of tissue optical property and blood flow from speckle contrast diffuse correlation tomography (scDCT) measurements.

Authors:  Mingjun Zhao; Chong Huang; Siavash Mazdeyasna; Guoqiang Yu
Journal:  Biomed Opt Express       Date:  2021-09-01       Impact factor: 3.732

10.  Noninvasive noncontact speckle contrast diffuse correlation tomography of cerebral blood flow in rats.

Authors:  Chong Huang; Siavash Mazdeyasna; Li Chen; Elie G Abu Jawdeh; Henrietta S Bada; Kathryn E Saatman; Lei Chen; Guoqiang Yu
Journal:  Neuroimage       Date:  2019-05-18       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.