Literature DB >> 28570094

Femoral Torsion: Impact of Femur Position on CT and Stereoradiography Measurements.

Gérard Morvan1, Henri Guerini1, Grégory Carré1, Valérie Vuillemin1.   

Abstract

OBJECTIVE: The purpose of this study is to evaluate stereoradiographic measurements of femoral torsion with different femoral positions, in comparison with CT measurements, with use of the current standard axial-slice technique. We hypothesize that CT measurements vary with femoral spatial positioning because of the resulting projection onto the CT plane, whereas stereoradiographic measurements, which are derived from a 3D reconstruction of the femur, remain constant.
MATERIALS AND METHODS: Both in vitro and in vivo studies were conducted. CT and stereoradiographic examinations were performed using 30 dry femurs in the following six femoral positions: neutral position (with the femoral mechanical axis aligned with the longitudinal axis of the CT scanner or stereoradiography system), 10° of abduction, 10° of adduction, 5° of flexion, 10° of flexion, and 5° of extension. The impact of femoral position on torsion measurement was assessed using paired t tests. In addition, 18 patients (mean [± SD] age, 42.3 ± 19.9 years) who underwent both CT and stereoradiography examinations were retrospectively assessed. The correlation between femoral positioning and torsion measurement was determined using the Pearson correlation coefficient.
RESULTS: Flexion and extension statistically significantly affected CT measurement of femoral torsion (p < 0.01) but not stereoradiography measurement (p > 0.21). A strong correlation existed between hip flexion and the difference between femoral torsion measured by CT and stereoradiography (r = -0.80).
CONCLUSION: The accuracy of femoral torsion determined by axial CT depends on the position of the femur. Hip flexion significantly reduced the femoral torsion angle measured by CT. Conversely, the accuracy of stereoradiography was independent of femur positioning. Thus, stereoradiography is preferable to CT for accurate measurement of femoral torsion, while it also substantially reduces the radiation dose.

Entities:  

Keywords:  CT; accuracy; femoral torsion; patient positioning; stereoradiography

Mesh:

Year:  2017        PMID: 28570094     DOI: 10.2214/AJR.16.16638

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  6 in total

1.  Biplanar Low-Dose Radiography Is Accurate for Measuring Combined Anteversion After Total Hip Arthroplasty.

Authors:  Christina I Esposito; Theodore T Miller; Joseph D Lipman; Kaitlin M Carroll; Douglas E Padgett; David J Mayman; Seth A Jerabek
Journal:  HSS J       Date:  2019-02-05

2.  Femoral and tibial torsion measurements based on EOS imaging compared to 3D CT reconstruction measurements.

Authors:  Wenqiang Yan; Xingquan Xu; Qian Xu; Wenjin Yan; Ziying Sun; Qing Jiang; Dongquan Shi
Journal:  Ann Transl Med       Date:  2019-09

3.  Application of three-dimensional reconstruction to improve the preoperative measurement accuracy and applicability of femoral neck torsion angle.

Authors:  Qing Han; Aobo Zhang; Chenyu Wang; Kerong Yang; Jincheng Wang
Journal:  Medicine (Baltimore)       Date:  2019-11       Impact factor: 1.817

4.  Clinically Significant Outcome Improvement After Hip Arthroscopy in Patients With Femoroacetabular Impingement Syndrome and Severe Femoral Torsion.

Authors:  Steven F DeFroda; Thomas D Alter; Blake M Bodendorfer; Alexander C Newhouse; Felipe S Bessa; Joel C Williams; Shane J Nho
Journal:  Orthop J Sports Med       Date:  2021-10-06

Review 5.  O papel da estereorradiografia na avaliação das deformidades dos membros inferiores.

Authors:  Flávio Duarte Silva; Renan Nogueira Chemin; Alípio Gomes Ormond Filho; Júlio Brandão Guimarães; Fernando Ometto Zorzenoni; Marcelo Astolfi Caetano Nico
Journal:  Radiol Bras       Date:  2022 Mar-Apr

6.  Three-dimensional morphological analysis of the femoral neck torsion angle-an anatomical study.

Authors:  Ru-Yi Zhang; Xiu-Yun Su; Jing-Xin Zhao; Jian-Tao Li; Li-Cheng Zhang; Pei-Fu Tang
Journal:  J Orthop Surg Res       Date:  2020-05-27       Impact factor: 2.359

  6 in total