Literature DB >> 28559422

Comparison of corneal dynamic parameters and tomographic measurements using Scheimpflug imaging in keratoconus.

Tommy Cy Chan1, Yu Meng Wang1, Marco Yu2, Vishal Jhanji1,3.   

Abstract

AIM: To compare the diagnostic ability of corneal tomography and corneal dynamic response measurements in normal and keratoconus eyes.
METHODS: Consecutive patients with grade II-III keratoconus and age-matched normal subjects were recruited. Corneal imaging was performed using Pentacam (Oculus Optikgeräte, Wetzlar, Germany) and Corvis (Oculus Optikgeräte). A beta version of Corvis software was used with three additional parameters: maximal change of arc length, deformation amplitude (DA) ratio 1 and DA ratio 2. Diagnostic ability of both devices to differentiate normal and keratoconus eyes was evaluated using receiver-operating characteristic (ROC) curves. The areas under the ROC curve (AUC) and partial AUC (pAUC) for specificity ≥80% for each parameter of Corvis and final D value of Belin/Ambrosio Enhanced Ectasia Display (BAD) were compared.
RESULTS: Forty-two eyes of 42 patients (21 patients with keratoconus and 21 normal subjects) were included. Both groups were age matched (p=0.760). The ROC analysis showed that the final D value of BAD had the highest AUC (0.994) and pAUC (0.194). Maximum inverse radius had the highest AUC (0.954) but a relatively lower pAUC (0.158), while DA ratio 2 had the second highest AUC (0.946) together with the highest pAUC (0.177) among Corvis parameters. There was no significant difference between AUC and pAUC of BAD compared with those of DA ratio 1 (p≥0.162) and DA ratio 2 (p≥0.208).
CONCLUSIONS: The results of our study suggest that Corvis measurements have the potential to differentiate keratoconus and normal eyes. The diagnostic ability of novel parameters on Corvis was comparable to Pentacam. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

Entities:  

Keywords:  corneal dynamic response; keratoconus; scheimpflug imaging; tomography

Mesh:

Year:  2017        PMID: 28559422     DOI: 10.1136/bjophthalmol-2017-310355

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  19 in total

1.  Comparison of corneal biological parameters between transepithelial and epithelium-off corneal cross-linking in keratoconus.

Authors:  Bo-Wen Ouyang; Hui Ding; Han Wang; Zhen-Duo Yang; Tan Zhong; Hong-Ming Fan; Xing-Wu Zhong
Journal:  Int J Ophthalmol       Date:  2021-07-18       Impact factor: 1.779

2.  Correlation between corneal dynamic responses and keratoconus topographic parameters.

Authors:  Hsi-Yun Tai; Jun-Ji Lin; Yi-Hung Huang; Po-Jen Shih; I-Jong Wang; Jia-Yush Yen
Journal:  J Int Med Res       Date:  2022-06       Impact factor: 1.573

3.  Altered tear inflammatory profile in Indian keratoconus patients - The 2015 Col Rangachari Award paper.

Authors:  Rohit Shetty; Rashmi Deshmukh; Arkasubhra Ghosh; Swaminathan Sethu; Chaitra Jayadev
Journal:  Indian J Ophthalmol       Date:  2017-11       Impact factor: 1.848

4.  Diagnostic Sensitivity of Different Reference Bodies When Using Scheimpflug Tomography in a Myopic Population with Keratoconus.

Authors:  Daniel Garcerant; Ignacio Jiménez-Alfaro; Nicolás Alejandre
Journal:  J Ophthalmol       Date:  2019-07-18       Impact factor: 1.909

Review 5.  Advances in Biomechanical Parameters for Screening of Refractive Surgery Candidates: A Review of the Literature, Part III.

Authors:  Majid Moshirfar; Mahsaw N Motlagh; Michael S Murri; Hamed Momeni-Moghaddam; Yasmyne C Ronquillo; Phillip C Hoopes
Journal:  Med Hypothesis Discov Innov Ophthalmol       Date:  2019

Review 6.  Pentacam® Corneal Tomography for Screening of Refractive Surgery Candidates: A Review of the Literature, Part I.

Authors:  Mahsaw N Motlagh; Majid Moshirfar; Michael S Murri; David F Skanchy; Hamed Momeni-Moghaddam; Yasmyne C Ronquillo; Phillip C Hoopes
Journal:  Med Hypothesis Discov Innov Ophthalmol       Date:  2019

7.  Reliability of a New Swept-Source Optical Coherence Tomography Biometer in Healthy Children, Adults, and Cataract Patients.

Authors:  Jinhai Huang; Yuyu Zhao; Giacomo Savini; Guanshun Yu; Jinjin Yu; Zhongxing Chen; Ruixue Tu; Yune Zhao
Journal:  J Ophthalmol       Date:  2020-05-15       Impact factor: 1.909

8.  Repeatability and comparison of new Corvis ST parameters in normal and keratoconus eyes.

Authors:  Kaili Yang; Liyan Xu; Qi Fan; Dongqing Zhao; Shengwei Ren
Journal:  Sci Rep       Date:  2019-10-25       Impact factor: 4.379

9.  Evaluation of new Corvis ST parameters in normal, Post-LASIK, Post-LASIK keratectasia and keratoconus eyes.

Authors:  Kaili Yang; Liyan Xu; Qi Fan; Yuwei Gu; Peng Song; Bo Zhang; Dongqing Zhao; Chenjiu Pang; Shengwei Ren
Journal:  Sci Rep       Date:  2020-03-30       Impact factor: 4.379

10.  Assessment of Corneal Pachymetry Distribution and Morphologic Changes in Subclinical Keratoconus with Normal Biomechanics.

Authors:  Peng Song; Kaili Yang; Pei Li; Yu Liu; Dengfeng Liang; Shengwei Ren; Qingyan Zeng
Journal:  Biomed Res Int       Date:  2019-11-19       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.