Literature DB >> 28559193

Effect of Stem Size and Fixation Method on Mechanical Failure After Revision Total Knee Arthroplasty.

Andrew N Fleischman1, Ibrahim Azboy1, Michael Fuery1, Camilo Restrepo1, Hongyi Shao1, Javad Parvizi1.   

Abstract

BACKGROUND: Although the need for stemmed components is well accepted to improve mechanical survival in revision total knee arthroplasty (TKA), the ideal fixation method and stem design remain controversial.
METHODS: We performed a retrospective review of 223 patients who underwent revision TKA in whom stemmed components had not been used previously and with a mean follow-up of 61.6 months, including 108 components with fully cemented stems and 316 components with "hybrid" press-fit stems.
RESULTS: Based on a time to event model, risk for mechanical failure was equivalent for both cemented and hybrid stems (relative risk, 0.991; P = .98). Young age was the single greatest risk factor for mechanical failure (P = .006). Although there was a trend toward increased failure with cemented stems in patients aged <65 years, there was no significant difference in risk after accounting for covariates (relative risk, 1.4; P = .50). Intramedullary canal fill, not stem length or diameter, was the strongest predictor of failure with hybrid stems, and risk was reduced by 41.2% for each additional 10% canal fill.
CONCLUSION: In conclusion, both cemented and hybrid modular stems are viable options in revision TKA. Surgeons should attempt to maximize canal filling of hybrid stems to obtain a solid press-fit. In addition, further studies are needed to evaluate the long-term survival of cemented stem fixation in young patients.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  aseptic loosening; cemented stem; hybrid stem; knee arthroplasty; revision knee

Mesh:

Year:  2017        PMID: 28559193     DOI: 10.1016/j.arth.2017.04.055

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  8 in total

1.  A case series of cementless revision total knee arthroplasty in patients with benzoyl peroxide allergy.

Authors:  Frank S Fröschen; Nadine Gravius; Jan-Frederic Lau; Thomas Martin Randau; Eva Kaup; Max J Friedrich; Sascha Gravius
Journal:  Int Orthop       Date:  2018-12-11       Impact factor: 3.075

2.  Tibial shaft anatomy differs between Caucasians and East Asian individuals.

Authors:  Hongyi Shao; Chilung Chen; Daniel Scholl; Ahmad Faizan; Antonia F Chen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-09-22       Impact factor: 4.342

3.  Comparison of radiographic vs. computed tomography canal filling ratio measurement of stems in revision knee prostheses.

Authors:  Osman Cimen; Mehmet Akif Kaygusuz
Journal:  J Orthop       Date:  2022-08-27

4.  No difference in long-term micromotion between fully cemented and hybrid fixation in revision total knee arthroplasty: a randomized controlled trial.

Authors:  Kelly Mills; Ate B Wymenga; Gijs G van Hellemondt; Petra J C Heesterbeek
Journal:  Bone Joint J       Date:  2022-07       Impact factor: 5.385

Review 5.  Stem Fixation in Revision Total Knee Arthroplasty: Indications, Stem Dimensions, and Fixation Methods.

Authors:  Se Gu Kang; Cheol Hee Park; Sang Jun Song
Journal:  Knee Surg Relat Res       Date:  2018-09-01

6.  Comparing Revision Total Knee Arthroplasty Stems at a High-Volume Revision Center.

Authors:  Bernard P Kemker; Christopher B Sowers; Raees Seedat; Jibanananda Satpathy; Nirav K Patel; Daniel J Lombardo; Gregory J Golladay
Journal:  Front Surg       Date:  2022-03-11

7.  Radiographic Assessment of Aseptic Loosening of Tumor-Type Knee Prosthesis in Distal Femur.

Authors:  Zi-Ming Li; Xiu-Chun Yu; Kai Zheng
Journal:  Orthop Surg       Date:  2022-05-07       Impact factor: 2.279

8.  The use of tantalum cones and diaphyseal-engaging stems in tibial component revision: a consecutive series.

Authors:  P Spinello; R A Ruberte Thiele; K Zepeda; N Giori; P F Indelli
Journal:  Knee Surg Relat Res       Date:  2022-03-10
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.