Literature DB >> 28557670

Validity and reliability of the Moxy oxygen monitor during incremental cycling exercise.

E M Crum1, W J O'Connor1, L Van Loo2, M Valckx2, S R Stannard1.   

Abstract

INTRODUCTION: The Moxy is a novel, cutaneously placed muscle oxygen monitor which claims to measure local oxygen saturation (SmO2) and total haemoglobin (THb) using near-infrared spectroscopy. If shown to be reliable, its data storage and telemetric capability will be useful for assessing localised O2 usage during field-based exercise. This study investigated the reliability of the Moxy during cycling and assessed the correlations between its measurements, whole-body O2 consumption (VO2) and heart rate (HR).
METHODS: Ten highly trained cyclists performed an incremental, step-wise cycling protocol on two occasions while wearing the Moxy. SmO2, THb, VO2 and HR were recorded in the final minute of each five-minute stage. Data were analysed using Spearman's Order-Rank Coefficient (SROC), Intraclass Correlation (ICC), and Coefficient of Variance (COV). Significance was set at p ≤ .05.
RESULTS: SmO2 showed a 'strong' or 'very large' correlation between trials (SROC: r = 0.842-0.993, ICC: r = 0.773-0.992, p ≤ .01) and was moderately correlated with VO2 and HR (r = -0.71-0.73, p ≤ .01). SmO2 showed a moderate to high reliability at low intensities, but this decreased as relative exercise intensity increased. THb showed poor correlations between tests and with the other measured variables, but was highly reliable at all power outputs.
CONCLUSIONS: The Moxy is a reliable device to measure SmO2 at low to moderate intensities, but at higher intensities, greater variation in measurements occurs, likely due to tissue ischaemia or increased movement artefacts due to more frequent muscular contractions. THb has low variation during exercise, and does not appear to be a valid indicator of muscle oxygenation.

Entities:  

Keywords:  Exercise; physiology; technology; training

Mesh:

Substances:

Year:  2017        PMID: 28557670     DOI: 10.1080/17461391.2017.1330899

Source DB:  PubMed          Journal:  Eur J Sport Sci        ISSN: 1536-7290            Impact factor:   4.050


  33 in total

Review 1.  Review of early development of near-infrared spectroscopy and recent advancement of studies on muscle oxygenation and oxidative metabolism.

Authors:  Takafumi Hamaoka; Kevin K McCully
Journal:  J Physiol Sci       Date:  2019-07-29       Impact factor: 2.781

Review 2.  Muscle Oximetry in Sports Science: A Systematic Review.

Authors:  Stephane Perrey; Marco Ferrari
Journal:  Sports Med       Date:  2018-03       Impact factor: 11.136

3.  Effect of external compression on femoral retrograde shear and microvascular oxygenation in exercise trained and recreationally active young men.

Authors:  Patricia Pagan Lassalle; Adam J Palamar; Jacob P DeBlois; Wesley K Lefferts; Kevin S Heffernan
Journal:  Eur J Appl Physiol       Date:  2019-06-12       Impact factor: 3.078

4.  Estimating the Lactate Threshold Using Wireless Near-Infrared Spectroscopy and Threshold Detection Analyses.

Authors:  Trent E Cayot; Shara G Robinson; Lindsay E Davis; Paul A Bender; John R Thistlethwaite; Craig E Broeder; Jakob D Lauver
Journal:  Int J Exerc Sci       Date:  2021-04-01

5.  Aging alters gastrocnemius muscle hemoglobin oxygen saturation (StO2) characteristics in healthy individuals.

Authors:  Michael Holmes; Panagiotis Koutakis; Ahmed Ismaeel
Journal:  Eur J Appl Physiol       Date:  2022-04-13       Impact factor: 3.078

6.  The Effects of Static and Dynamic Stretching on Muscle Oxygen Saturation in the Rectus Femoris.

Authors:  Zachary R Brodeur; Michael J Paustian; Drew A Monteleone-Haught; Robert A Lamm; Annaliza G Pagano; Carrie E Ellis
Journal:  Int J Exerc Sci       Date:  2022-05-01

7.  Inter-set rest configuration effect on acute physiological and performance-related responses to a resistance training session in terrestrial vs simulated hypoxia.

Authors:  Cristina Benavente; Belén Feriche; Guillermo Olcina; Brad J Schoenfeld; Alba Camacho-Cardenosa; Filipa Almeida; Ismael Martínez-Guardado; Rafael Timon; Paulino Padial
Journal:  PeerJ       Date:  2022-05-18       Impact factor: 3.061

8.  Acute caffeine intake increases muscle oxygen saturation during a maximal incremental exercise test.

Authors:  Carlos Ruíz-Moreno; Beatriz Lara; Diego Brito de Souza; Jorge Gutiérrez-Hellín; Blanca Romero-Moraleda; Ángel Cuéllar-Rayo; Juan Del Coso
Journal:  Br J Clin Pharmacol       Date:  2020-01-14       Impact factor: 4.335

9.  Augmented muscle glycogen utilization following a single session of sprint training in hypoxia.

Authors:  Nobukazu Kasai; Fumiya Tanji; Aya Ishibashi; Hayato Ohnuma; Hideyuki Takahashi; Kazushige Goto; Yasuhiro Suzuki
Journal:  Eur J Appl Physiol       Date:  2021-07-06       Impact factor: 3.078

10.  Muscle Oxygen Demands of the Vastus Lateralis in Back and Front Squats.

Authors:  Patrick R Davis; John P Yakel; Deven J F Anderson
Journal:  Int J Exerc Sci       Date:  2020-05-01
View more