| Literature DB >> 28545121 |
Keunheung Park1, Jinmi Kim2, Jiwoong Lee1,3.
Abstract
BACKGROUND: Retinal ganglion cell (RGC) death is a common cause of loss of vision during glaucoma. Pattern electroretinogram (PERG) is an objective measure of the central retinal function that correlates with macular GCL thickness. The aim of this study is to determine possible relationships between the N95 amplitude of pattern electroretinogram (PERGamp) and macular ganglion cell/inner plexiform layer thickness (GCIPLT). METHODS ANDEntities:
Mesh:
Year: 2017 PMID: 28545121 PMCID: PMC5435332 DOI: 10.1371/journal.pone.0178004
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Fig 1Calculation of central visual field sensitivity.
Total deviation values (TDn) of central 12 points (out of 54 points) are unlogged, averaged, and finally logged again to transform back to the decibel scale.
Demographic characteristics of the healthy and glaucomatous subjects.
| Healthy (n = 66) | Glaucoma (n = 74) | |||
|---|---|---|---|---|
| Early (n = 44) | Advanced (n = 30) | |||
| Age (year) | 48.3 ± 14.2 | 49.5 ± 14.6 | 58.4 ± 12.9 | 0.004 |
| Female/Male (number of patient) | 41 / 25 | 23 / 21 | 13 / 17 | 0.209 |
| Diabetes (number of patient) | 4 | 5 | 5 | 0.258 |
| Hypertension (number of patient) | 9 | 10 | 11 | 0.038 |
| Axial length (mm) | 24.26 ± 1.45 | 24.42 ± 1.77 | 24.31 ± 1.53 | 0.897 |
| Spherical equivalent (diopters) | –1.76 ± 2.80 | –1.74 ± 3.20 | –1.31 ± 3.25 | 0.473 |
| Central corneal thickness (μm) | 558.8 ± 32.7 | 544.6 ± 32.0 | 541.8 ± 35.5 | 0.029 |
| VF MD (dB) | –0.97 ± 1.49 | –3.23 ± 1.64 | –12.2 ± 5.87 | <0.001 |
| VF PSD (dB) | 1.83 ± 0.85 | 3.59 ± 2.13 | 9.76 ± 2.89 | <0.001 |
| VF VFI (%) | 98.56 ± 1.52 | 92.86 ± 12.14 | 67.87 ± 20.07 | <0.001 |
| Mean PERGamp (μV) | 7.11 ± 2.20 | 5.30 ± 1.72 | 4.87 ± 1.78 | <0.001 |
| Mean GCIPL thickenss (μm) | 81.91 ± 6.12 | 74.59 ± 7.43 | 66.33 ± 8.56 | <0.001 |
| Mean RNFL thickness (μm) | 33.42 ± 3.62 | 29.52 ± 4.90 | 25.23 ± 5.30 | <0.001 |
VF MD visual field mean deviation, VF PSD visual field pattern standard deviation, VF VFI visual field visual field index, PERGamp pattern electroretinogram N95 amplitude (peak of P50 to the trough of N95), GC/IPL ganglion cell/inner plexiform layer, RNFL retinal nerve fiber layer
a one-way ANOVA test
b χ2 test
c Kruskal-Wallis test
The relationship between ganglion cell/inner plexiform layer thickness and pattern electroretinogram amplitude or central visual field central sensitivities or mean deviation by regression models.
| Broken stick | Linear regression | Quadratic regression | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Tipping point | Davies’ Test | Slope 1 | R2 | AIC | Slope | R2 | AIC | Beta1 | R2 | AIC | ||||
| Slope 2 | Beta2 | |||||||||||||
| △Slope | ||||||||||||||
| GCIPLT | 88.0 | 0.934 | 0.12 | <0.001 | 0.227 | 591.4 | 0.111 | <0.001 | 0.220 | 588.7 | 0.043 | 0.841 | 0.221 | 590.6 |
| vs. | –0.04 | 0.831 | 0.001 | 0.750 | ||||||||||
| PERGamp | –0.16 | 0.395 | ||||||||||||
| GCIPLT | 71.9 | <0.001 | 0.37 | <0.001 | 0.483 | 597.1 | 0.184 | <0.001 | 0.389 | 616.3 | 1.157 | <0.001 | 0.466 | 599.6 |
| vs. | 0.06 | 0.050 | –0.007 | <0.001 | ||||||||||
| VFcenter | –0.31 | <0.001 | ||||||||||||
| GCIPLT | 72.1 | <0.001 | 0.74 | <0.001 | 0.512 | 773.8 | 0.366 | <0.001 | 0.414 | 795.4 | 2.303 | <0.001 | 0.495 | 776.6 |
| vs. | 0.13 | 0.058 | –0.013 | <0.001 | ||||||||||
| VFMD | –0.61 | <0.001 | ||||||||||||
VF visual field mean deviation; VF central visual field sensitivity; PERG pattern electroretinogram N95 amplitude (peak of P50 to the trough of N95), GCIPLT ganglion cell/inner plexiform layer thickness
a Davies’ test P value: the probability of that the tipping point is not statistically significant.
b slope below the tipping point
c slope above the tipping point
d Akaike information criterion. The lower value means the better fitted model.
Fig 2Scatter plots showing relationship between ganglion cell/inner plexiform layer (GCIPL) thickness and pattern electroretinogram N95 amplitude (PERGamp) in entire study sample.
Three different regression models applied; (A) broken stick model (B) linear regression model (C) quadratic regression model. The best fit model for GCIPL thickness and PERGamp was linear regression model (r2 = 0.220, P < <0.001, AIC = 588.7).
Fig 3Scatter plots showing relationship of central visual field sensitivities (VFcenter) (A, B, C) or visual field mean deviation (VFMD) (D, E, F) with ganglion cell/inner plexiform layer (GCIPL) thickness in entire study sample. Three regression models were applied (broken stick model / linear regression mode / quadratic regression model respectively from left to right). For the GCIPL thickness and VFcenter, broken stick model was best fitted model with significant tipping point (Davies’ test P < 0.001) where the location was 71.9 μm. The broken stick model was best fitting model for the GCIPL thickness and VFMD among the three different regression models. The tipping point was significant (Davies’ test P < 0.001) where the location was 72.1 μm. VF visual field centeral sensitivity, VF visual field mean deviation, GCIPL ganglion cell/ inner plexiform layer.
Pearson’s correlation coefficient for structural and functional measures in normal subjects (n = 66 eyes).
| PERGamp | VFMD | VFCenter | GCIPL thickness | |
|---|---|---|---|---|
| VFMD | 0.020 | |||
| VFCenter | 0.053 | 0.910a | ||
| GCIPL thickness | 0.195 | 0.204 | 0.165 | |
| RNFL thickness | 0.197 | 0.094 | 0.074 | 0.405 |
VF visual field mean deviation, VF central visual field sensitivity, PERG pattern electroretinogram N95 amplitude (peak of P50 to the trough of N95), GC/IPL ganglion cell/inner plexiform layer, RNFL retinal nerve fiber layer
aP < 0.01
Pearson’s or Spearman’s correlation coefficient for structural and functional measures in patients with advanced glaucoma (n = 30 eyes).
| PERGamp | VFMD | VFCenter | GCIPL thickness | |
|---|---|---|---|---|
| VFMD | 0.047 | |||
| VFCenter | 0.079 | 0.547 | ||
| GCIPL thickness | 0.505 | 0.503 | 0.431 | |
| RNFL thickness | 0.459 | 0.453 | 0.313 | 0.778 |
VF visual field mean deviation, VF central visual field sensitivity, PERG pattern electroretinogram N95 amplitude (peak of P50 to the trough of N95), GC/IPL ganglion cell/inner plexiform layer, RNFL retinal nerve fiber layer
aP < 0.01
bP < 0.05
cSpearman’s rho
Pearson’s or Spearman’s correlation coefficient for structural and functional measures in patients with early glaucoma (n = 44 eyes).
| PERGamp | VFMD | VFCenter | GCIPL thickness | |
|---|---|---|---|---|
| VFMD | –0.018 | |||
| VFCenter | –0.061 | 0.853 | ||
| GCIPL thickness | 0.331 | –0.070 | 0.052 | |
| RNFL thickness | –0.048 | 0.198 | 0.291 | 0.413 |
VF visual field mean deviation, VF central visual field sensitivity, PERG pattern electroretinogram N95 amplitude (peak of P50 to the trough of N95), GC/IPL ganglion cell/inner plexiform layer, RNFL retinal nerve fiber layer
aP < 0.01
bP < 0.05
cSpearman’s rho