Clinical Use of Continuous Glucose Monitoring in Adults with Type 1 Diabetes.

David Slattery1, Pratik Choudhary1.   

Abstract

With the emphasis on intensive management of type 1 diabetes, data from studies support frequent monitoring of glucose levels to improve glycemic control and reduce glucose variability, which can be related to an increase in macro and microvascular complications. However, few perform capillary blood glucose that frequently. There are currently two available alternatives that this review will discuss, continuous glucose monitoring (CGM) and flash glucose monitoring. CGM has become an important diagnostic and therapeutic option in optimizing diabetes management. CGM systems are now more accurate, smaller, and easier to use compared to original models. Randomized controlled trials (RCTs) have demonstrated that CGM can improve Hemoglobin A1c (HbA1C) and reduce glucose variability in both continuous subcutaneous insulin infusion and multiple daily injection users. When used in an automated "insulin-suspend" system, reduced frequency of hypoglycemia and shorter time spent in hypoglycemic range have been demonstrated. Despite the potential benefits CGM has to offer in clinical practice, concerns exist on the accuracy of these devices and patient compliance with therapy, which may prevent the true clinical benefit of CGM being achieved, as observed in RCTs. Flash glucose monitoring systems FreeStyle® Libre™ (Abbott Diabetes Care, Alameda, CA) are as accurate as many CGM systems available and have the added benefit of being factory calibrated. Studies have shown that flash glucose monitoring systems are very well tolerated by patients and effectively reduce glucose variability, increasing time in range.

Entities:  

Keywords:  Continuous glucose monitoring; Flash glucose monitoring; Glycemic control; Hypoglycemia; Type 1 diabetes

Mesh:

Substances:

Year:  2017        PMID: 28541131      PMCID: PMC5444504          DOI: 10.1089/dia.2017.0051

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  38 in total

Review 1.  The MiniMed Continuous Glucose Monitoring System (CGMS).

Authors:  J Mastrototaro
Journal:  J Pediatr Endocrinol Metab       Date:  1999       Impact factor: 1.634

2.  Is the frequency of self-monitoring of blood glucose related to long-term metabolic control? Multicenter analysis including 24,500 patients from 191 centers in Germany and Austria.

Authors:  M Schütt; W Kern; U Krause; P Busch; A Dapp; R Grziwotz; I Mayer; J Rosenbauer; C Wagner; A Zimmermann; W Kerner; R W Holl
Journal:  Exp Clin Endocrinol Diabetes       Date:  2006-07       Impact factor: 2.949

3.  Improvement in Glucose Control in Difficult-to-Control Patients With Diabetes Using a Novel Flash Glucose Monitoring Device.

Authors:  Maya Ish-Shalom; Julio Wainstein; Itamar Raz; Ofri Mosenzon
Journal:  J Diabetes Sci Technol       Date:  2016-11-01

4.  Continuous glucose monitoring for patients with type 1 diabetes and impaired awareness of hypoglycaemia (IN CONTROL): a randomised, open-label, crossover trial.

Authors:  Cornelis A J van Beers; J Hans DeVries; Susanne J Kleijer; Mark M Smits; Petronella H Geelhoed-Duijvestijn; Mark H H Kramer; Michaela Diamant; Frank J Snoek; Erik H Serné
Journal:  Lancet Diabetes Endocrinol       Date:  2016-09-15       Impact factor: 32.069

5.  Prevention of hypoglycemia by using low glucose suspend function in sensor-augmented pump therapy.

Authors:  Thomas Danne; Olga Kordonouri; Martin Holder; Holger Haberland; Sven Golembowski; Kerstin Remus; Sara Bläsig; Tanja Wadien; Susanne Zierow; Reinhard Hartmann; Andreas Thomas
Journal:  Diabetes Technol Ther       Date:  2011-08-09       Impact factor: 6.118

6.  Effect of Continuous Glucose Monitoring on Glycemic Control in Adults With Type 1 Diabetes Using Insulin Injections: The DIAMOND Randomized Clinical Trial.

Authors:  Roy W Beck; Tonya Riddlesworth; Katrina Ruedy; Andrew Ahmann; Richard Bergenstal; Stacie Haller; Craig Kollman; Davida Kruger; Janet B McGill; William Polonsky; Elena Toschi; Howard Wolpert; David Price
Journal:  JAMA       Date:  2017-01-24       Impact factor: 56.272

7.  Continuous glucose monitoring and intensive treatment of type 1 diabetes.

Authors:  William V Tamborlane; Roy W Beck; Bruce W Bode; Bruce Buckingham; H Peter Chase; Robert Clemons; Rosanna Fiallo-Scharer; Larry A Fox; Lisa K Gilliam; Irl B Hirsch; Elbert S Huang; Craig Kollman; Aaron J Kowalski; Lori Laffel; Jean M Lawrence; Joyce Lee; Nelly Mauras; Michael O'Grady; Katrina J Ruedy; Michael Tansey; Eva Tsalikian; Stuart Weinzimer; Darrell M Wilson; Howard Wolpert; Tim Wysocki; Dongyuan Xing
Journal:  N Engl J Med       Date:  2008-09-08       Impact factor: 91.245

8.  Threshold-based insulin-pump interruption for reduction of hypoglycemia.

Authors:  Richard M Bergenstal; David C Klonoff; Satish K Garg; Bruce W Bode; Melissa Meredith; Robert H Slover; Andrew J Ahmann; John B Welsh; Scott W Lee; Francine R Kaufman
Journal:  N Engl J Med       Date:  2013-06-22       Impact factor: 91.245

9.  Recovery of hypoglycemia awareness in long-standing type 1 diabetes: a multicenter 2 × 2 factorial randomized controlled trial comparing insulin pump with multiple daily injections and continuous with conventional glucose self-monitoring (HypoCOMPaSS).

Authors:  Stuart A Little; Lalantha Leelarathna; Emma Walkinshaw; Horng Kai Tan; Olivia Chapple; Alexandra Lubina-Solomon; Thomas J Chadwick; Shalleen Barendse; Deborah D Stocken; Catherine Brennand; Sally M Marshall; Ruth Wood; Jane Speight; David Kerr; Daniel Flanagan; Simon R Heller; Mark L Evans; James A M Shaw
Journal:  Diabetes Care       Date:  2014-05-22       Impact factor: 19.112

10.  REPLACE-BG: A Randomized Trial Comparing Continuous Glucose Monitoring With and Without Routine Blood Glucose Monitoring in Adults With Well-Controlled Type 1 Diabetes.

Authors:  Grazia Aleppo; Katrina J Ruedy; Tonya D Riddlesworth; Davida F Kruger; Anne L Peters; Irl Hirsch; Richard M Bergenstal; Elena Toschi; Andrew J Ahmann; Viral N Shah; Michael R Rickels; Bruce W Bode; Athena Philis-Tsimikas; Rodica Pop-Busui; Henry Rodriguez; Emily Eyth; Anuj Bhargava; Craig Kollman; Roy W Beck
Journal:  Diabetes Care       Date:  2017-02-16       Impact factor: 19.112

View more
  20 in total

1.  Flash Glucose Monitoring: The Future Is Here.

Authors:  Satish K Garg; Halis Kaan Akturk
Journal:  Diabetes Technol Ther       Date:  2017-05       Impact factor: 6.118

2.  Continuous Glucose Monitoring: Current Use in Diabetes Management and Possible Future Applications.

Authors:  Martina Vettoretti; Giacomo Cappon; Giada Acciaroli; Andrea Facchinetti; Giovanni Sparacino
Journal:  J Diabetes Sci Technol       Date:  2018-05-22

3.  Performance of the Prototype NovioSense Noninvasive Biosensor for Tear Glucose in Type 1 Diabetes.

Authors:  Petronella Geelhoed-Duijvestijn; Dovile Vegelyte; Alicja Kownacka; Nicoleta Anton; Maurits Joosse; Christopher Wilson
Journal:  J Diabetes Sci Technol       Date:  2020-10-23

Review 4.  Therapeutic cell engineering: designing programmable synthetic genetic circuits in mammalian cells.

Authors:  Maysam Mansouri; Martin Fussenegger
Journal:  Protein Cell       Date:  2021-09-29       Impact factor: 15.328

Review 5.  Continuous Glucose Monitoring Integration in Clinical Practice: A Stepped Guide to Data Review and Interpretation.

Authors:  Grazia Aleppo; Kimberly Webb
Journal:  J Diabetes Sci Technol       Date:  2018-11-19

6.  Perceived Burdens and Benefits Associated With Continuous Glucose Monitor Use in Type 1 Diabetes Across the Lifespan.

Authors:  Vidita Divan; Margaret Greenfield; Christopher P Morley; Ruth S Weinstock
Journal:  J Diabetes Sci Technol       Date:  2020-12-24

7.  Variables associated with HbA1c and weight reductions when adding liraglutide to multiple daily insulin injections in persons with type 2 diabetes (MDI Liraglutide trial 3).

Authors:  Sofia Dahlqvist; Elsa Ahlén; Karin Filipsson; Thomas Gustafsson; Irl B Hirsch; Jaakko Tuomilehto; Henrik Imberg; Bo Ahrén; Stig Attvall; Marcus Lind
Journal:  BMJ Open Diabetes Res Care       Date:  2018-02-24

8.  Assessing Diabetes Distress and Sleep Quality in Young Adults with Type 1 Diabetes Using FreeStyle Libre: A Prospective Cohort Study.

Authors:  Ayman A Al Hayek; Mohamed A Al Dawish
Journal:  Diabetes Ther       Date:  2020-06-04       Impact factor: 2.945

9.  The Potential Impact of the FreeStyle Libre Flash Glucose Monitoring System on Mental Well-Being and Treatment Satisfaction in Patients with Type 1 Diabetes: A Prospective Study.

Authors:  Ayman A Al Hayek; Mohamed A Al Dawish
Journal:  Diabetes Ther       Date:  2019-05-07       Impact factor: 2.945

10.  Evaluation of FreeStyle Libre Flash Glucose Monitoring System on Glycemic Control, Health-Related Quality of Life, and Fear of Hypoglycemia in Patients with Type 1 Diabetes.

Authors:  Ayman A Al Hayek; Asirvatham A Robert; Mohamed A Al Dawish
Journal:  Clin Med Insights Endocrinol Diabetes       Date:  2017-12-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.