Literature DB >> 28534560

Re-configurable, multi-mode contained-electrospray ionization for protein folding and unfolding on the millisecond time scale.

Colbert F Miller1, Dmytro S Kulyk, Jongin W Kim, Abraham K Badu-Tawiah.   

Abstract

A new reconfigurable contained-electrospray (ES) ion source is described that can be operated in three unique modes (Types I, II and III) and was applied to control the charge state of proteins for subsequent online characterization by mass spectrometry. Using this device, proteins prepared in 100% water were highly charged after exposure to hydrochloric acid vapor. For myoglobin, the shift to a higher charge state occurred faster than the heme cofactor could escape the unfolding protein. This effect reflected in the detection of highly charged holo-myoglobin intermediates (+26), which suggests the modification process occurred on a millisecond time scale (Type I mode). By introducing a cavity in the contained-ES emitter (Type II mode), increased protein denaturation was observed where only apo-myoglobin ions were detected. A similar increase in the charge effect was observed for less pH sensitive proteins such as ubiquitin and cytochrome c. In a third type of experiment, acidified aqueous-based droplets containing unfolded proteins were briefly exposed to aqueous ammonium acetate/triethylammonium acetate solution mixtures to increase the droplet pH and to induce protein folding during electrospray ionization. Charge-state distributions showed protein folding occurred, including the appearance of charged reduced species that were not observed when sprayed in pure water. The three operational modes of contained-electrospray allow online modification of an analyte during charge droplet formation using both vapor and non-volatile liquid reagents, without a direct addition of the modifying reagent to the analyte solution.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28534560     DOI: 10.1039/c7an00362e

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  4 in total

1.  Direct Mass Spectrometry Analysis of Complex Mixtures by Nanoelectrospray with Simultaneous Atmospheric Pressure Chemical Ionization and Electrophoretic Separation Capabilities.

Authors:  Dmytro S Kulyk; Devin J Swiner; Taghi Sahraeian; Abraham K Badu-Tawiah
Journal:  Anal Chem       Date:  2019-09-06       Impact factor: 6.986

2.  Melting proteins confined in nanodroplets with 10.6 μm light provides clues about early steps of denaturation.

Authors:  Tarick J El-Baba; Daniel R Fuller; Daniel W Woodall; Shannon A Raab; Christopher R Conant; Jonathan M Dilger; Yoni Toker; Evan R Williams; David H Russell; David E Clemmer
Journal:  Chem Commun (Camb)       Date:  2018-03-27       Impact factor: 6.222

3.  Microsampling with a Solid-Phase Extraction Cartridge: Storage and Online Mass Spectrometry Analysis.

Authors:  Dmytro S Kulyk; Taghi Sahraeian; Suji Lee; Abraham K Badu-Tawiah
Journal:  Anal Chem       Date:  2021-09-30       Impact factor: 6.986

4.  Vibrating Sharp-edge Spray Ionization (VSSI) for voltage-free direct analysis of samples using mass spectrometry.

Authors:  Xiaojun Li; Kushani Attanayake; Stephen J Valentine; Peng Li
Journal:  Rapid Commun Mass Spectrom       Date:  2018-08-19       Impact factor: 2.419

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.