| Literature DB >> 28533599 |
Akmer Mutlu1, Mohammad Dawood Kharooty1, Yavuz Yakut1.
Abstract
[Purpose] The aim of this study was to investigate the effect of segmental weight of the prosthesis on hemodynamic responses and energy expenditure in lower extremity amputees.Entities:
Keywords: Amputation; Hemodynamic responses; Prosthesis
Year: 2017 PMID: 28533599 PMCID: PMC5430262 DOI: 10.1589/jpts.29.629
Source DB: PubMed Journal: J Phys Ther Sci ISSN: 0915-5287
The comparison of distance and duration in functional performance tests without weight and with weight
| Functional Performance Tests (n=13) | Mean ± SD | Minimum | Maximum | t |
|---|---|---|---|---|
| 6MWT without weight (m) | 380.0 ± 79.8 | 219.0 | 542.5 | 3.346* |
| 6MWT with weight (m) | 365.1 ± 82.3 | 218.0 | 533.3 | |
| 10 stairs up & down without weight (sec) | 17.6 ± 6.8 | 10.0 | 31.0 | −0.670 |
| 10 stairs up & down without weight (sec) | 17.9 ± 6.8 | 9.0 | 30.0 |
n: number of patients; 6MWT: 6 minute walk test; SD: standard deviation; m: meter, sec: second, *Statistically significant, p<0.05
Comparison of hemodynamic responses for 6MWT
| 6MWTB (n=13) | Mean ± SD | Mean diff ± SD | ||
|---|---|---|---|---|
| HR (bpm) | Before | without weight | 75.0 ± 8.7 | −1.5 ± 3.6 |
| with weight | 77.7 ± 10.1 | |||
| After | without weight | 80.9 ± 9.0 | −3.1 ± 4.5 | |
| with weight | 83.9 ± 8.9 | |||
| SBP (mmHg) | Before | without weight | 116.5 ± 12.0 | 0.4 ± 3.8 |
| with weight | 116.2 ± 11.9 | |||
| After | without weight | 116.0 ± 11.2 | −1.9 ± 3.3 | |
| with weight | 117.7 ± 12.4 | |||
| DBP (mmHg) | Before | without weight | 76.5 ± 8.8 | 1.5 ± 5.6 |
| with weight | 75.0 ± 8.7 | |||
| After | without weight | 74.6 ± 8.8 | 0.0 ± 2.0 | |
| with weight | 74.6 ± 9.0 | |||
| DP (mmHg.bpm) | Before | without weight | 8,600.0 ± 1,540.5 | −157.7 ± 472.6 |
| with weight | 8,757.7 ± 1,650.4 | |||
| After | without weight | 9,406.2 ± 1,683.1 | −508.5 ± 589.1 | |
| with weight | 9,914.6 ± 1,750.6 | |||
6MWT: 6 minute walk test; n: number of patients; SD: standard deviation; mean diff: Mean difference; HR: heart rate; bpm: beats per minute; SBP: systolic blood pressure; DBP: diastolic blood pressure; DP: Double Product; mmHg: millimeters of mercury, *Statistically significant, p<0.05
Comparison of hemodynamic responses for 10 stairs up and down
| 10 stairs up & down (n=13) | Mean ± SD | Mean diff ± SD | |||
|---|---|---|---|---|---|
| HR (bpm) | Before | without weight | 69.1 ± 15.4 | −8.3 ± 18.9 | |
| With weight | 77.4 ± 9.5 | ||||
| After | without weight | 80.9 ± 8.8 | −3.6 ± 4.2 | * | |
| With weight | 84.5 ± 8.7 | ||||
| SBP (mmHg) | Before | without weight | 115.4 ± 12.2 | −1.2 ± 3.0 | |
| With weight | 116.5 ± 13.1 | ||||
| After | without weight | 115.4 ± 12.2 | −3.1 ± 5.6 | ||
| With weight | 118.5 ± 13.5 | ||||
| DBP (mmHg) | B efore | without weight | 76.5 ± 9.4 | 0.4 ± 1.4 | |
| With weight | 76.2 ± 9.8 | ||||
| After | without weight | 75.5 ± 9.1 | −0.6 ± 2.2 | ||
| With weight | 76.2 ± 9.8 | ||||
| DP (mmHg.bpm) | Before | without weight | 7,994.2 ± 2,173.2 | −1,072.3 ± 2,513.5 | |
| with weight | 9,066.5 ± 1,777.8 | ||||
| After | without weight | 1,629.0 ± 451.8 | 297.7 ± 856.7 | ||
| with weight | 1,777.8 ± 493.1 | ||||
SD: standard deviation; n: number of patients; Mean diff: mean difference; HR: heart rate; bpm: beats per minute; SBP: systolic blood pressure; DBP: diastolic blood pressure; DP: Double Product; mmHg: millimeters of mercury, *Statistically significant, p<0.05
Physiological Cost Index of patients without weight and with weight paired samples test
| PCI (pulse/m) | Mean ± SD | Mean diff ± SD | |
|---|---|---|---|
| Without weight | 79.6 ± 8.8 | −2.9 ± 4.5 | * |
| With weight | 82.6 ± 8.6 |
PCI: Physiological Cost Index; pulse/m: pulse per minute; SD: standard deviation; Mean diff: mean difference; HR: heart rate; SBP: systolic blood pressure; DBP: diastolic blood pressure, *Statistically significant, p<0.05