Literature DB >> 28530161

Dual microcatheter coil embolization of acutely ruptured wide-necked intracranial aneurysms.

Pyeong-Ho Yoon1, Jae-Wook Lee1, Yun-Ho Lee2, Young-Sub Kwon2, Kook-Hee Yang2.   

Abstract

The dual microcatheter technique is an alternative treatment for stent-assisted coiling in acutely ruptured wide-necked aneurysms because of no antiplatelet therapy. We assessed the safety and efficacy of this technique in ruptured wide-necked aneurysms. Between March 2008 and March 2016, 56 acutely ruptured aneurysms were treated with the dual microcatheter technique. The angiographic results, treatment-related complications, and clinical outcome were documented. Angiographic follow-up was available in 37 patients at a mean of 20.6 months (6 to 81 months). On the postembolization angiograms, 27 (48.2%) aneurysms showed complete occlusion (Raymond 1), 15 (26.8%) showed neck remnant (Raymond 2), and 14 (25.0%) showed body remnant (Raymond 3). Treatment-related complications occurred in seven patients (12.5%) and six patients remained asymptomatic. The permanent complication rate was 1.8% (1/56). A good outcome (modified Rankin Scale (mRS) score, 0-2) was observed in 64.3% of patients at the time of discharge. Five patients had died, all of the sequelae of subarachnoid hemorrhage. The overall mortality rate was 8.9% (5/56); however, the treatment-related mortality rate was 0%. Of the 37 aneurysms for which angiographic follow-up was available, 21 (56.8%) aneurysms demonstrated recanalization. Five aneurysms with recanalization were retreated endovascularly. There was one aneurysm re-rupture on follow-up and it rebled 21 months after the initial procedure. The dual microcatheter technique is a safe and effective treatment for acutely ruptured wide-necked aneurysms due to low treatment-related complication and mortality rate. However, the high rate of postembolization incomplete occlusion and recanalization remains as the main challenge.

Entities:  

Keywords:  Coil embolization; dual microcatheter coil embolization; stent-assisted coiling

Mesh:

Year:  2017        PMID: 28530161      PMCID: PMC5624404          DOI: 10.1177/1591019917708570

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  30 in total

1.  Long-term results of enterprise stent-assisted coiling of cerebral aneurysms.

Authors:  Kyle M Fargen; Brian L Hoh; Babu G Welch; G Lee Pride; Giuseppe Lanzino; Alan S Boulos; Jeffrey S Carpenter; Ansaar Rai; Erol Veznedaroglu; Andrew Ringer; Rafael Rodriguez-Mercado; Peter Kan; Adnan Siddiqui; Elad I Levy; J Mocco
Journal:  Neurosurgery       Date:  2012-08       Impact factor: 4.654

2.  Single-center experience with a dual microcatheter technique for the endovascular treatment of wide-necked aneurysms.

Authors:  Christopher R Durst; Robert M Starke; John R Gaughen; Scott Geraghty; K Derek Kreitel; Ricky Medel; Nicholas Demartini; Kenneth C Liu; Mary E Jensen; Avery J Evans
Journal:  J Neurosurg       Date:  2014-08-22       Impact factor: 5.115

3.  Late rebleeding of ruptured intracranial aneurysms treated with detachable coils.

Authors:  Menno Sluzewski; Willem Jan van Rooij; Guus N Beute; Peter C Nijssen
Journal:  AJNR Am J Neuroradiol       Date:  2005 Nov-Dec       Impact factor: 3.825

4.  Comparison of 2-year angiographic outcomes of stent- and nonstent-assisted coil embolization in unruptured aneurysms with an unfavorable configuration for coiling.

Authors:  G Hwang; H Park; J S Bang; S-C Jin; B C Kim; C W Oh; H S Kang; M H Han; O-K Kwon
Journal:  AJNR Am J Neuroradiol       Date:  2011-08-18       Impact factor: 3.825

Review 5.  Stent-assisted coiling in acutely ruptured intracranial aneurysms: a qualitative, systematic review of the literature.

Authors:  K D Bodily; H J Cloft; G Lanzino; D J Fiorella; P M White; D F Kallmes
Journal:  AJNR Am J Neuroradiol       Date:  2011-05-05       Impact factor: 3.825

6.  Intracranial aneurysms: treatment with bare platinum coils--aneurysm packing, complex coils, and angiographic recurrence.

Authors:  Michel Piotin; Laurent Spelle; Charbel Mounayer; Marco T Salles-Rezende; Daniel Giansante-Abud; Ricardo Vanzin-Santos; Jacques Moret
Journal:  Radiology       Date:  2007-02-09       Impact factor: 11.105

7.  Predictors of rehemorrhage after treatment of ruptured intracranial aneurysms: the Cerebral Aneurysm Rerupture After Treatment (CARAT) study.

Authors:  S Claiborne Johnston; Christopher F Dowd; Randall T Higashida; Michael T Lawton; Gary R Duckwiler; Daryl R Gress
Journal:  Stroke       Date:  2007-11-29       Impact factor: 7.914

8.  Endovascular treatment of unruptured wide-necked intracranial aneurysms: comparison of dual microcatheter technique and stent-assisted coil embolization.

Authors:  Robert M Starke; Christopher R Durst; Avery Evans; Dale Ding; Daniel M S Raper; Mary E Jensen; Richard W Crowley; Kenneth C Liu
Journal:  J Neurointerv Surg       Date:  2014-03-25       Impact factor: 5.836

9.  Stent-assisted coil embolization of ruptured wide-necked aneurysms in the acute period: incidence of and risk factors for periprocedural complications.

Authors:  Joonho Chung; Yong Cheol Lim; Sang Hyun Suh; Yu Shik Shim; Yong Bae Kim; Jin-Yang Joo; Bum-Soo Kim; Yong Sam Shin
Journal:  J Neurosurg       Date:  2014-05-16       Impact factor: 5.115

10.  Reporting standards for endovascular repair of saccular intracranial cerebral aneurysms.

Authors:  P M Meyers; H C Schumacher; R T Higashida; C P Derdeyn; G M Nesbit; D Sacks; L R Wechsler; J B Bederson; S D Lavine; P Rasmussen
Journal:  AJNR Am J Neuroradiol       Date:  2010-01       Impact factor: 4.966

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.