Literature DB >> 28527853

Influence of Intracanal Materials in Vertical Root Fracture Pathway Detection with Cone-beam Computed Tomography.

Kamile Leonardi Dutra1, Camila Pachêco-Pereira2, Eduardo Antunes Bortoluzzi3, Carlos Flores-Mir4, Manuel O Lagravère4, Márcio Corrêa5.   

Abstract

INTRODUCTION: Investigating the vertical root fracture (VRF) pathway under different clinical scenarios may help to diagnose this condition properly. We aimed to determine the capability and intrareliability of VRF pathway detection through cone-beam computed tomographic (CBCT) imaging as well as analyze the influence of different intracanal and crown materials.
METHODS: VRFs were mechanically induced in 30 teeth, and 4 clinical situations were reproduced in vitro: no filling, gutta-percha, post, and metal crown. A Prexion (San Mateo, CA) 3-dimensional tomographic device was used to generate 104 CBCT scans. The VRF pathway was determined by using landmarks in the Avizo software (Version 8.1; FEI Visualization Sciences Group, Burlington, MA) by 1 observer repeated 3 times. Analysis of variance and post hoc tests were applied to compare groups.
RESULTS: Intrareliability demonstrated an excellent agreement (intraclass correlation coefficient mean = 0.93). Descriptive analysis showed that the fracture line measurement was smaller in the post and metal crown groups than in the no-filling and gutta-percha groups. The 1-way analysis of variance test found statistically significant differences among the groups measurements. The Bonferroni correction showed statistically significant differences related to the no-filling and gutta-percha groups versus the post and metal crown groups.
CONCLUSIONS: The VRF pathway can be accurately detected in a nonfilled tooth using limited field of view CBCT imaging. The presence of gutta-percha generated a low beam hardening artifact that did not hinder the VRF extent. The presence of an intracanal gold post made the fracture line appear smaller than it really was in the sagittal images; in the axial images, a VRF was only detected when the apical third was involved. The presence of a metal crown did not generate additional artifacts on the root surface compared to the intracanal gold post by itself.
Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Cone-beam computed tomography; diagnostic accuracy; endodontic treatment; vertical root fracture

Mesh:

Substances:

Year:  2017        PMID: 28527853     DOI: 10.1016/j.joen.2017.02.006

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  3 in total

1.  In vivo detection of vertical root fractures in endodontically treated teeth: Accuracy of cone-beam computed tomography and assessment of potential predictor variables.

Authors:  Marcela Quintero-Álvarez; Leslie-Melissa Bolaños-Alzate; Paula-Andrea Villa-Machado; Felipe-Augusto Restrepo-Restrepo; Sergio-Iván Tobón-Arroyave
Journal:  J Clin Exp Dent       Date:  2021-02-01

2.  Accuracy of three cone-beam CT devices and two software systems in the detection of vertical root fractures.

Authors:  Aline Pf Caetano; Thiago O Sousa; Mariana R Oliveira; Karine Evanglista; Juliano M Bueno; Maria Ag Silva
Journal:  Dentomaxillofac Radiol       Date:  2020-12-01       Impact factor: 2.419

Review 3.  Diagnosis of cracked teeth using cone-beam computed tomography: literature review and clinical experience.

Authors:  Antian Gao; Dantong Cao; Zitong Lin
Journal:  Dentomaxillofac Radiol       Date:  2021-04-29       Impact factor: 3.525

  3 in total