Literature DB >> 28527202

Diagnostic accuracy of contrast-enhanced ultrasound (CEUS) in monitoring vascular complications in patients after liver transplantation - diagnostic performance compared with histopathological results.

J Rübenthaler1, K J Paprottka1, E Hameister1, K Hoffmann1, N Joiko1, M Reiser1, D Rjosk-Dendorfer1, D A Clevert1.   

Abstract

PURPOSE: To analyse the diagnostic performance of contrast-enhanced ultrasound (CEUS) in patients with vascular complications and transplant rejection compared to histopathological results.
MATERIALS AND METHODS: Our study consisted of 45 retrospectively analysed patients that underwent liver transplantations between January 1993 and December 2015 and developed post-transplant vascular complications with transplant rejection. CEUS examinations took place between September 2006 and December 2015. CEUS findings were correlated with histopathological results.
RESULTS: CEUS showed a sensitivity of 61.5%, a specificity of 100.0%, a positive predictive value (PPV) of 100.0% and a negative predictive value (NPV) of 86,5% in the detection of vascular complications with post-transplant rejection. 5 examinations were reported as normal whereas the histopathological result showed a transplant rejection (false-negative).
CONCLUSION: CEUS might be a useful additional non-invasive technique for the assessment of vascular complications with post-transplant rejection in patients after liver transplantation.

Entities:  

Keywords:  CEUS (Contrast-enhanced ultrasound), histopathology; liver transplantation; transplant rejection; vascular complication

Mesh:

Substances:

Year:  2017        PMID: 28527202     DOI: 10.3233/CH-179105

Source DB:  PubMed          Journal:  Clin Hemorheol Microcirc        ISSN: 1386-0291            Impact factor:   2.375


  5 in total

Review 1.  [CEUS-diagnosis of benign liver lesions].

Authors:  K Müller-Peltzer; J Rübenthaler; G Negrao de Figueiredo; D A Clevert
Journal:  Radiologe       Date:  2018-06       Impact factor: 0.635

Review 2.  Contrast-enhanced ultrasound of transplant organs - liver and kidney - in children.

Authors:  Doris Franke; Reza J Daugherty; Damjana Ključevšek; Aikaterini Ntoulia; Vasileios Rafailidis; Marcelo S Takahashi; Alvaro Torres; Bernarda Viteri; Frank M Volberg
Journal:  Pediatr Radiol       Date:  2021-05-12

3.  Hepatic Artery Occlusion after Liver Transplantation in Patients with Doppler Ultrasound Abnormality: Increasing Sensitivity of Contrast-Enhanced Ultrasound Diagnosis.

Authors:  Jin Sil Kim; Kyoung Won Kim; Sang Hyun Choi; So Yeong Jeong; Jae Hyun Kwon; Gi Won Song; Sung Gyu Lee
Journal:  Korean J Radiol       Date:  2019-03       Impact factor: 3.500

Review 4.  Computational Modeling in Liver Surgery.

Authors:  Bruno Christ; Uta Dahmen; Karl-Heinz Herrmann; Matthias König; Jürgen R Reichenbach; Tim Ricken; Jana Schleicher; Lars Ole Schwen; Sebastian Vlaic; Navina Waschinsky
Journal:  Front Physiol       Date:  2017-11-14       Impact factor: 4.566

5.  Multi-parameter ultrasound based on the logistic regression model in the differential diagnosis of hepatocellular adenoma and focal nodular hyperplasia.

Authors:  Meng Wu; Ru-Hai Zhou; Feng Xu; Xian-Peng Li; Ping Zhao; Rui Yuan; Yu-Peng Lan; Wei-Xia Zhou
Journal:  World J Gastrointest Oncol       Date:  2019-12-15