Literature DB >> 29704011

[CEUS-diagnosis of benign liver lesions].

K Müller-Peltzer1, J Rübenthaler2, G Negrao de Figueiredo2, D A Clevert2.   

Abstract

CLINICAL/METHODICAL ISSUE: Focal liver lesions are commonly seen during routine ultrasound examinations. STANDARD RADIOLOGICAL
METHODS: With native ultrasound there are lesions that cannot be sufficiently characterized. In these cases additional imaging might be necessary. METHODICAL INNOVATIONS: With contrast-enhanced ultrasound (CEUS), focal liver lesions can be characterized with high diagnostic accuracy. After the ultrasound contrast agent has been injected into a peripheral vein, the examiner saves video loops of the arterial, portal venous and late contrast phases. Combing the findings of native and contrast-enhanced ultrasound allows not only assessment of the etiology as benign or malignant but also detailed characterization of the focal liver lesion in most cases. PERFORMANCE: Using CEUS, focal liver lesions can be characterized with a sensitivity of over 95% and a specificity of about 83%. ACHIEVEMENTS: The advantages of CEUS include that there is no radiation exposure and that the ultrasound contrast agent has no effects on the function of the liver, kidneys or the thyroid gland. The main limiting factors for CEUS are bowel gas and obesity of the patient. PRACTICAL RECOMMENDATIONS: CEUS can visualize micro- and macrovascularization of benign focal liver lesions in real time. It is a useful imaging modality in unclear cases.

Entities:  

Keywords:  Focal nodular hyperplasia; Hemangioma; Liver cysts; Ultrasonography; Washout

Mesh:

Substances:

Year:  2018        PMID: 29704011     DOI: 10.1007/s00117-018-0390-8

Source DB:  PubMed          Journal:  Radiologe        ISSN: 0033-832X            Impact factor:   0.635


  30 in total

1.  The safety of Sonovue in abdominal applications: retrospective analysis of 23188 investigations.

Authors:  Fabio Piscaglia; Luigi Bolondi
Journal:  Ultrasound Med Biol       Date:  2006-09       Impact factor: 2.998

2.  Diagnostic performance of contrast-enhanced ultrasound for complex cystic focal liver lesions: blinded reader study.

Authors:  Man-Xia Lin; Hui-Xiong Xu; Ming-De Lu; Xiao-Yan Xie; Li-Da Chen; Zuo-Feng Xu; Guang-Jian Liu; Xiao-Hua Xie; Jin-Yu Liang; Zhu Wang
Journal:  Eur Radiol       Date:  2008-09-16       Impact factor: 5.315

3.  Ultrasound contrast agents as markers of vascularity and microcirculation.

Authors:  Christian Greis
Journal:  Clin Hemorheol Microcirc       Date:  2009       Impact factor: 2.375

Review 4.  Contrast-Enhanced Ultrasound (CEUS) of the Kidneys by Using the Bosniak Classification.

Authors:  J Rübenthaler; F Bogner; M Reiser; D A Clevert
Journal:  Ultraschall Med       Date:  2016-04-08       Impact factor: 6.548

5.  Vascular complications in liver transplantation: Beneficial role of contrast-enhanced ultrasound (CEUS) in the postoperative phase.

Authors:  J Rübenthaler; K J Paprottka; E Hameister; K Hoffmann; N Joiko; M Reiser; D A Clevert
Journal:  Clin Hemorheol Microcirc       Date:  2016       Impact factor: 2.375

6.  The added value of contemporary ultrasound technologies in the diagnosis of malignant tumours of the gastrointestinal system - a case report.

Authors:  Johannes Rübenthaler; Maximilian Reiser; Dirk-André Clevert
Journal:  Med Ultrason       Date:  2018-02-04       Impact factor: 1.611

7.  Comparison of magnetic resonance imaging (MRI) and contrast-enhanced ultrasound (CEUS) in the evaluation of unclear solid renal lesions.

Authors:  J Rübenthaler; K Paprottka; J Marcon; E Hameister; K Hoffmann; N Joiko; M Reiser; D A Clevert
Journal:  Clin Hemorheol Microcirc       Date:  2016       Impact factor: 2.375

Review 8.  Contrast-enhanced ultrasound (CEUS) in blunt abdominal trauma.

Authors:  Vittorio Miele; Claudia Lucia Piccolo; Michele Galluzzo; Stefania Ianniello; Barbara Sessa; Margherita Trinci
Journal:  Br J Radiol       Date:  2016-01-08       Impact factor: 3.039

9.  Contrast-enhanced ultrasound for the characterization of focal liver lesions--diagnostic accuracy in clinical practice (DEGUM multicenter trial).

Authors:  D Strobel; K Seitz; W Blank; A Schuler; C Dietrich; A von Herbay; M Friedrich-Rust; G Kunze; D Becker; U Will; W Kratzer; F W Albert; C Pachmann; K Dirks; H Strunk; C Greis; T Bernatik
Journal:  Ultraschall Med       Date:  2008-10       Impact factor: 6.548

10.  Prevalence of benign focal liver lesions: ultrasound investigation of 45,319 hospital patients.

Authors:  Tanja Eva-Maria Kaltenbach; Phillip Engler; Wolfgang Kratzer; Suemeyra Oeztuerk; Thomas Seufferlein; Mark Martin Haenle; Tilmann Graeter
Journal:  Abdom Radiol (NY)       Date:  2016-01
View more
  4 in total

1.  [Contrast-enhanced ultrasound: Tingling].

Authors:  S Delorme; D-A Clevert
Journal:  Radiologe       Date:  2018-06       Impact factor: 0.635

2.  [Benign liver tumors : Diagnostics and treatment].

Authors:  H-M Tautenhahn; U Dahmen; I Diamantis; U Settmacher; J Zanow
Journal:  Chirurg       Date:  2019-12       Impact factor: 0.955

Review 3.  Contrast-enhanced ultrasound perfusion imaging of organs.

Authors:  Ernst-Michael Jung; Marc-André Weber; Isabel Wiesinger
Journal:  Radiologe       Date:  2021-08-10       Impact factor: 0.635

4.  Multimodal Imaging under Artificial Intelligence Algorithm for the Diagnosis of Liver Cancer and Its Relationship with Expressions of EZH2 and p57.

Authors:  Yamin Zhang; Jie Cui; Wei Wan; Jinpeng Liu
Journal:  Comput Intell Neurosci       Date:  2022-03-14
  4 in total