Literature DB >> 28525823

Development and validation of a reversed-phase HPLC method for analysis of radiochemical purity in [123I]IBZM.

Shiou-Shiow Farn1, Yuen-Han Yeh2, Chang-Chin Li2, Ching-Shiuann Yang2, Jenn-Tzong Chen2, Chung-Shan Yu3, Wuu-Jyh Lin4.   

Abstract

[123I]IBZM is used widely for in vivo imaging of D2 receptors in human brain and shows relatively fast kinetics and a greater susceptibility to synaptic dopamine release than other single-photon emission computed tomography (SPECT) radioligands. A reliable and reversed-phase HPLC method using UV/VIS and radiometric detectors has been developed for qualitative analysis of BZM and IBZM and radiochemical purity in [123I]IBZM preparations. The method uses gradient elution on a Zorbax XDB C-18 column with a mobile phase that consists of 10mM 3,3-dimethylglutaric acid (DMGA), pH 7.0 and acetonitrile (ACN). The flow rate was 1.0mL/min with detection at λ=254nm. The method was validated for system suitability, precision, accuracy, specificity, linearity, robustness, limit of detection (LOD) and limit of quantification (LOQ), as described in ICH guidelines. The results are described as follows: (1) The system suitability includes the tailing factor, theoretical plate number and resolution, which are 0.962, 10656.11 and 9.367, respectively. (2) For specificity, the BZM and [123I]NH4I did not interfere with the retention time of the [123I]IBZM. (3) The percentage coefficient of variation for analysis of precision, including repeatability and intermediate precision, is less than 2.0%. (4) Accuracy of the method is within the range of 85-100%. (5) The range of linearity is from 100% to 70% radiochemical purity (%RCP) of [123I]IBZM, with the correlation coefficient (R) always being above 0.995. (6) The data of method robustness are within acceptance criteria. (7) The LOD and LOQ for impurity (BZM) are 0.145 and 0.50μg/mL, respectively. All of the analysis results demonstrate that this method is sensitive, specific and suitable for routine analysis of the radiochemical purity in [123I]IBZM preparations.
Copyright © 2017. Published by Elsevier Ltd.

Entities:  

Keywords:  Radiochemical purity and method validation; Reversed-phase HPLC; [(123)I]IBZM

Year:  2017        PMID: 28525823     DOI: 10.1016/j.apradiso.2017.04.022

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  1 in total

1.  Development and Validation of Analytical Methods for Radiochemical Purity of 177Lu-PSMA-1.

Authors:  Pauline Orhon; Marie-Dominique Desruet; Marie Piquemal; Nicolas De Leiris; Loïc Djaileb; Jean-Philippe Vuillez; Pierrick Bedouch; Julien Leenhardt
Journal:  Pharmaceuticals (Basel)       Date:  2022-04-24
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.