Literature DB >> 28522245

Pin Site Complications Associated With Computer-Assisted Navigation in Hip and Knee Arthroplasty.

Eli Kamara1, Zachary P Berliner1, Matthew S Hepinstall1, H John Cooper2.   

Abstract

BACKGROUND: There has been a great increase in the use of navigation technology in joint arthroplasty. In most types of navigation-assisted surgery, several temporary navigation pins are placed in the patient. Goals of this study are (1) to identify complications and (2) risk factors associated with placement of these pins.
METHODS: This is a retrospective cohort study of all navigation-assisted hip and knee arthroplasty performed a single institution over a 3-year period. Records were reviewed and outcome measures were tabulated in a database. Complications included in the database were pin site infection, deep prosthetic joint infection, neurologic injury, vascular injury, and fracture through a pin site.
RESULTS: A total of 3136 pin sites in 839 patients were included in the study. Five pin site complications were reported with a complication rate of 0.16% per pin site and 0.60% per patient. The complications-per-procedure were slightly higher for unicondylar knee arthroplasty (0.64%) compared with patellofemoral arthroplasty (0%) and total hip arthroplasty (0.46%), but not statistically significant. There were three infections, one neuropraxia, and one suture abscess. No periprosthetic fractures through a pin site were reported. All complications were resolved with nonoperative treatment. The infections required oral antibiotics, and were associated with transcortical drilling in two cases and juxtacortical drilling in the third.
CONCLUSION: Pins required for navigation-assisted arthroplasty have a low complication rate. Transcortical or juxtacortical drilling may be a risk factor for pin site infection; future studies should be directed at quantifying this effect.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  computer navigation; computer-assisted surgery; pin sites; postoperative complications; tracker pin

Mesh:

Year:  2017        PMID: 28522245     DOI: 10.1016/j.arth.2017.03.073

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  12 in total

1.  Is sequential bilateral robotic total knee arthroplasty a safe procedure? A matched comparative pilot study.

Authors:  Cécile Batailler; Mike B Anderson; Xavier Flecher; Matthieu Ollivier; Sébastien Parratte
Journal:  Arch Orthop Trauma Surg       Date:  2022-05-10       Impact factor: 3.067

2.  [Short-term effectiveness of novel computer navigation system assisted total knee arthroplasty].

Authors:  Qiheng Tang; Yixin Zhou; Shengjie Guo; Wang Deng; Zhaolun Wang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-10-15

3.  A new robotically assisted technique can improve outcomes of total knee arthroplasty comparing to an imageless navigation system.

Authors:  Fabio Mancino; Stefano Marco Paolo Rossi; Rudy Sangaletti; Ludovico Lucenti; Flavio Terragnoli; Francesco Benazzo
Journal:  Arch Orthop Trauma Surg       Date:  2022-08-01       Impact factor: 2.928

Review 4.  Advances in Patellofemoral Arthroplasty.

Authors:  Sabrina M Strickland; Mackenzie L Bird; Alexander B Christ
Journal:  Curr Rev Musculoskelet Med       Date:  2018-06

5.  Comparison of a novel handheld accelerometer-based navigation system and conventional instrument for performing distal femoral resection in total knee arthroplasty: a randomized controlled trial.

Authors:  Xingquan Xu; Peilai Liu; Zhenfeng Yuan; Dawei Wang; Qunshan Lu; Zhe Zhang; Qing Jiang; Dongquan Shi
Journal:  Ann Transl Med       Date:  2019-11

6.  Robotic-assisted total knee arthroplasty is comparable to conventional total knee arthroplasty: a meta-analysis and systematic review.

Authors:  James Randolph Onggo; Jason Derry Onggo; Richard De Steiger; Raphael Hau
Journal:  Arch Orthop Trauma Surg       Date:  2020-06-14       Impact factor: 3.067

7.  Navigated versus Conventional Technique in High Tibial Osteotomy: A Meta-Analysis Focusing on Weight Bearing Effect.

Authors:  Kyung Wook Nha; Young-Soo Shin; Hyuk Min Kwon; Jae Ang Sim; Young Gon Na
Journal:  Knee Surg Relat Res       Date:  2019-06-01

8.  Accelerometer-Based Navigation in Total Knee Arthroplasty for the Management of Extra-Articular Deformity and Retained Femoral Hardware: Analysis of Component Alignment.

Authors:  Andrea Cozzi Lepri; Matteo Innocenti; Fabrizio Matassi; Marco Villano; Roberto Civinini; Massimo Innocenti
Journal:  Joints       Date:  2019-10-11

9.  Electromagnetic navigation system for acetabular component placement in total hip arthroplasty is more precise and accurate than the freehand technique: a randomized, controlled trial with 84 patients.

Authors:  Rene Mihalič; Jurij Zdovc; Janez Mohar; Rihard Trebše
Journal:  Acta Orthop       Date:  2020-07-01       Impact factor: 3.717

10.  Retained pelvic pin site debris after navigated total hip replacement: Masquerading as an early-stage chondrosarcomatous lesion.

Authors:  A P Kurmis
Journal:  J Postgrad Med       Date:  2020 Oct-Dec       Impact factor: 1.476

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.