SU-E-T-96: Energy Dependence of the New GafChromic- EBT3 Film's Dose Response-Curve.

S Chiu-Tsao1,2,3, G Massillon-Jl1,2,3, I Domingo-Muñoz1,2,3, M Chan1,2,3.   

Abstract

PURPOSE: To study and compare the dose response curves of the new GafChromic EBT3 film for megavoltage and kilovoltage x-ray beams, with different spatial resolution.
METHODS: Two sets of EBT3 films (lot#A101711-02) were exposed to each x-ray beam (6MV, 15MV and 50kV) at 8 dose values (50-3200cGy). The megavoltage beams were calibrated per AAPM TG-51 protocol while the kilovoltage beam was calibrated following the TG-61 using an ionization chamber calibrated at NIST. Each film piece was scanned three consecutive times in the center of Epson 10000XL flatbed scanner in transmission mode, landscape orientation, 48-bit color at two separate spatial resolutions of 75 and 300 dpi. The data were analyzed using ImageJ and, for each scanned image, a region of interest (ROI) of 2×2cm2 at the field center was selected to obtain the mean pixel value with its standard deviation in the ROI. For each energy, dose value and spatial resolution, the average netOD and its associated uncertainty were determined. The Student's t-test was performed to evaluate the statistical differences between the netOD/dose values of the three energy modalities, with different color channels and spatial resolutions.
RESULTS: The dose response curves for the three energy modalities were compared in three color channels with 75 and 300dpi. Weak energy dependence was found. For doses above 100cGy, no statistical differences were observed between 6 and 15MV beams, regardless of spatial resolution. However, statistical differences were observed between 50kV and the megavoltage beams. The degree of energy dependence (from MV to 50kV) was found to be function of color channel, dose level and spatial resolution.
CONCLUSIONS: The dose response curves for GafChromic EBT3 films were found to be weakly dependent on the energy of the photon beams from 6MV to 50kV. The degree of energy dependence varies with color channel, dose and spatial resolution. GafChromic EBT3 films were supplied by Ashland Corp. This work was partially supported by DGAPA-UNAM grant IN102610 and Conacyt Mexico grant 127409.
© 2012 American Association of Physicists in Medicine.

Keywords:  Data analysis; Image analysis; Image scanners; Ionization chambers; Photons; Spatial resolution

Year:  2012        PMID: 28517140     DOI: 10.1118/1.4735153

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Cellular Damage in the Target and Out-Of-Field Peripheral Organs during VMAT SBRT Prostate Radiotherapy: An In Vitro Phantom-Based Study.

Authors:  Igor Piotrowski; Katarzyna Kulcenty; Wiktoria Suchorska; Marcin Rucinski; Karol Jopek; Marta Kruszyna-Mochalska; Agnieszka Skrobala; Piotr Romanski; Adam Ryczkowski; Dorota Borowicz; Natalia Matuszak; Julian Malicki
Journal:  Cancers (Basel)       Date:  2022-05-30       Impact factor: 6.575

2.  An efficient protocol for radiochromic film dosimetry combining calibration and measurement in a single scan.

Authors:  David Lewis; Andre Micke; Xiang Yu; Maria F Chan
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.506

3.  An Experimental Slope Method for a More Accurate Measurement of Relative Radiation Doses using Radiographic and Radiochromic Films and Its Application to Megavoltage Small-Field Dosimetry.

Authors:  Raghavendra Holla; D Khanna; Bhaskaran K Pillai; K V Jafar Ali; P S Renil Mon; C O Clinto; Tharmarnadar Ganesh
Journal:  J Med Phys       Date:  2019 Jul-Sep

4.  Evaluating dosimetric accuracy of the 6 MV calibration on EBT3 film in the use of Ir-192 high dose rate brachytherapy.

Authors:  Lyu Huang; Hani Gaballa; Jenghwa Chang
Journal:  J Appl Clin Med Phys       Date:  2022-02-28       Impact factor: 2.243

5.  Expired EBT3 Films' Sensitivity for the Measurement of X-ray and UV Radiation: An Optical Analysis.

Authors:  Hamad Yahia Abu Mhanna; Ahmad Fairuz Omar; Yasmin Md Radzi; Hanan Fawaz Akhdar; Haytham Al Ewaidat
Journal:  Materials (Basel)       Date:  2022-04-15       Impact factor: 3.748

6.  Effect of scanning parameters on dose-response of radiochromic films irradiated with photon and electron beams.

Authors:  Nashrulhaq Tagiling; Raizulnasuha Ab Rashid; Siti Nur Amirah Azhan; Norhayati Dollah; Moshi Geso; Wan Nordiana Rahman
Journal:  Heliyon       Date:  2018-10-17

Review 7.  Patient Derived Models to Study Head and Neck Cancer Radiation Response.

Authors:  Pippa F Cosper; Lindsey Abel; Yong-Syu Lee; Cristina Paz; Saakshi Kaushik; Kwangok P Nickel; Roxana Alexandridis; Jacob G Scott; Justine Y Bruce; Randall J Kimple
Journal:  Cancers (Basel)       Date:  2020-02-12       Impact factor: 6.575

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.