Literature DB >> 28516563

Reply to "Comment on the 'Report of AAPM TG 204: Size-specific dose estimates (SSDE) in pediatric and adult body CT examinations'" [AAPM Report 204, 2011].

John M Boone1.   

Abstract

Keywords:  Computed tomography; Computerised tomographs; Digital computing or data processing equipment or methods, specially adapted for specific applications; Dose-volume analysis; Dosimetry; Editorials; Image data processing or generation, in general; Lungs; Medical image segmentation; Medical imaging; PACS; Physicists; Radiologists; Tissues; biological tissues; computerised tomography; dosimetry; image segmentation; lung; medical image processing; radiology

Year:  2012        PMID: 28516563      PMCID: PMC3412437          DOI: 10.1118/1.4725757

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


× No keyword cloud information.
  1 in total

1.  Effective doses to patients undergoing thoracic computed tomography examinations.

Authors:  W Huda; E M Scalzetti; M Roskopf
Journal:  Med Phys       Date:  2000-05       Impact factor: 4.071

  1 in total
  6 in total

1.  Patient-Specific Organ and Effective Dose Estimates in Adult Oncologic CT.

Authors:  Yiming Gao; Usman Mahmood; Tianyu Liu; Brian Quinn; Marc J Gollub; X George Xu; Lawrence T Dauer
Journal:  AJR Am J Roentgenol       Date:  2019-08-15       Impact factor: 3.959

2.  Considerations on the practical application of the size-specific dose estimation (SSDE) method of AAPM Report 204.

Authors:  Linhsia Noferini; Christian Fulcheri; Adriana Taddeucci; Marco Bartolini; Cesare Gori
Journal:  Radiol Phys Technol       Date:  2014-04-16

3.  Evaluation of AAPM Reports 204 and 220: Estimation of effective diameter, water-equivalent diameter, and ellipticity ratios for chest, abdomen, pelvis, and head CT scans.

Authors:  Christiane S Burton; Timothy P Szczykutowicz
Journal:  J Appl Clin Med Phys       Date:  2017-11-27       Impact factor: 2.102

4.  CARE Dose 4D combined with sinogram-affirmed iterative reconstruction improved the image quality and reduced the radiation dose in low dose CT of the small intestine.

Authors:  Lin Wang; Shenchu Gong; Jushun Yang; Jie Zhou; Jing Xiao; Jin-Hua Gu; Hong Yang; Jianfeng Zhu; Bosheng He
Journal:  J Appl Clin Med Phys       Date:  2018-12-03       Impact factor: 2.102

5.  An augmented patient-specific approach to administration of contrast agent for CT renal angiography.

Authors:  Charbel Saade; Nadine Hamieh; Ibrahim Al-Sheikh Deeb; Maurice Haddad; Alain S Abi-Ghanem; Diamond Ghieh; Fadi El-Merhi
Journal:  Int Braz J Urol       Date:  2019 Sep-Oct       Impact factor: 1.541

6.  Investigation of Eye Lens Dose Estimate based on AAPM Report 293 in Head Computed Tomography.

Authors:  Choirul Anam; Winda Kusuma Dewi; Masdi Masdi; Freddy Haryanto; Toshioh Fujibuchi; Geoff Dougherty
Journal:  J Biomed Phys Eng       Date:  2021-10-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.