A new approach to calibration and determination of selected trace elements in food contact polymers by LA-ICP-MS.

Monica Voss1, Matheus A G Nunes1, Gabriela Corazza1, Erico M M Flores1, Edson I Müller1, Valderi L Dressler2.   

Abstract

A calibration strategy using porous nylon disks and reference solutions is proposed for the first time for matrix matching and determination of As, Ba, Cd, Cr, Pb, Sr and Zn in polymers by laser ablation-inductively coupled plasma mass spectrometry (LA-ICP-MS). Polymer samples commonly used in contact with food were analyzed. The procedure consists on the use of porous nylon disks as support for a dried droplet reference solution. Calibration in the range of 0.50-190μgg-1 for Ba, Cd, Cr, Pb, Sr and Zn and from 0.30-9.0μgg-1 for As was used. Laser and ICP-MS instrument conditions were evaluated in order to achieve the best signal-to-background ratio. The radiofrequency power and carrier gas flow rate were fixed at 1300W and 1.25Lmin-1, respectively. Spot size, repetition rate, scan line speed and laser fluency were set to 100µm, 20Hz, 100µms-1 and 17.9Jcm-2, respectively, as the established conditions for analysis of standards and samples. By using these conditions, limits of detection, estimated considering B+3s (where B is the value of the blank and s is the standard deviation of 10 measurements of the blank), ranged from 0.09μgg-1 (208Pb) to 1.09 (53Cr) and 0.05μgg-1 (208Pb) to 2.10 (53Cr) for calibration with and without 13C as internal standard (IS). In spite to the use of nylon for matrix matching of different polymeric matrices, the normalization with 13C as IS was also evaluated. The precision of the method is relatively good (RSD<20%), and the accuracy of the method, evaluated by analysis of certified reference materials (CRM) and by comparison with results obtained from solution analysis by ICP-MS after sample decomposition by microwave induced combustion (MIC) is relatively good. The suitability of the proposed method resulted in direct and reliable analyses of polymer samples with a simplified or unnecessary sample preparation step. In addition, the calibration with dried droplet reference solutions may be considered a promising procedure in view of its advantages to other forms of calibration, as the use of CRM or the preparation of synthetic standards. The use of porous nylon disks spiked with reference solutions for calibration is the main advantage of the present work.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Calibration; Inductively coupled plasma-mass spectrometry; Laser ablation; Polymers samples

Mesh:

Substances:

Year:  2017        PMID: 28501200     DOI: 10.1016/j.talanta.2017.04.048

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  μ-Thin-layer chromatography coupled with laser ablation-inductively coupled plasma-mass spectrometry using tin(II)-imprinted polymer nanoparticles as a stationary phase for speciation of tin.

Authors:  Amir Shafiee Kisomi; Taher Alizadeh; Alireza Shakeri
Journal:  Mikrochim Acta       Date:  2020-04-28       Impact factor: 5.833

2.  Combined LA-ICP-MS/LIBS: powerful analytical tools for the investigation of polymer alteration after treatment under corrosive conditions.

Authors:  Lukas Brunnbauer; Maximilian Mayr; Silvia Larisegger; Michael Nelhiebel; Laura Pagnin; Rita Wiesinger; Manfred Schreiner; Andreas Limbeck
Journal:  Sci Rep       Date:  2020-07-27       Impact factor: 4.379

3.  Preparation of ashless cellulose paper standards for rapid determination of multi-element concentrations in airborne fine particulate matter using laser ablation inductively coupled plasma mass spectrometry.

Authors:  Lei Qiao; Ruijie Zhang; Jing Qiao; Xiaoyan He; Zhiwei Wu
Journal:  RSC Adv       Date:  2021-02-10       Impact factor: 3.361

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.