Literature DB >> 28480335

Toward Transoral Peripheral Lung Access: Combining Continuum Robots and Steerable Needles.

Philip J Swaney1, Arthur W Mahoney1, Bryan I Hartley2, Andria A Remirez1, Erik Lamers1, Richard H Feins3, Ron Alterovitz4, Robert J Webster1.   

Abstract

Lung cancer is the most deadly form of cancer in part because of the challenges associated with accessing nodules for diagnosis and therapy. Transoral access is preferred to percutaneous access since it has a lower risk of lung collapse, yet many sites are currently unreachable transorally due to limitations with current bronchoscopic instruments. Toward this end, we present a new robotic system for image-guided trans-bronchoscopic lung access. The system uses a bronchoscope to navigate in the airway and bronchial tubes to a site near the desired target, a concentric tube robot to move through the bronchial wall and aim at the target, and a bevel-tip steerable needle with magnetic tracking to maneuver through lung tissue to the target under closed-loop control. In this work, we illustrate the workflow of our system and show accurate targeting in phantom experiments. Ex vivo porcine lung experiments show that our steerable needle can be tuned to achieve appreciable curvature in lung tissue. Lastly, we present targeting results with our system using two scenarios based on patient cases. In these experiments, phantoms were created from patient-specific computed tomography information and our system was used to target the locations of suspicious nodules, illustrating the ability of our system to reach sites that are traditionally inaccessible transorally.

Entities:  

Year:  2016        PMID: 28480335      PMCID: PMC5415307          DOI: 10.1142/S2424905X17500015

Source DB:  PubMed          Journal:  J Med Robot Res


  29 in total

Review 1.  Needle insertion into soft tissue: a survey.

Authors:  Niki Abolhassani; Rajni Patel; Mehrdad Moallem
Journal:  Med Eng Phys       Date:  2006-08-28       Impact factor: 2.242

2.  Electromagnetic navigation diagnostic bronchoscopy in peripheral lung lesions.

Authors:  Ralf Eberhardt; Devanand Anantham; Felix Herth; David Feller-Kopman; Armin Ernst
Journal:  Chest       Date:  2007-03-30       Impact factor: 9.410

3.  Electromagnetic navigation diagnostic bronchoscopy for small peripheral lung lesions.

Authors:  D Makris; A Scherpereel; S Leroy; B Bouchindhomme; J-B Faivre; J Remy; P Ramon; C-H Marquette
Journal:  Eur Respir J       Date:  2007-03-14       Impact factor: 16.671

4.  Image-guided bronchoscopy for peripheral lung lesions: a phantom study.

Authors:  Scott A Merritt; Jason D Gibbs; Kun-Chang Yu; Viral Patel; Lav Rai; Duane C Cornish; Rebecca Bascom; William E Higgins
Journal:  Chest       Date:  2008-06-26       Impact factor: 9.410

5.  Concentric Tube Robots as Steerable Needles: Achieving Follow-the-Leader Deployment.

Authors:  Hunter B Gilbert; Joseph Neimat; Robert J Webster
Journal:  IEEE Trans Robot       Date:  2015-02-10       Impact factor: 5.567

6.  Behavior of tip-steerable needles in ex vivo and in vivo tissue.

Authors:  Ann Majewicz; Steven P Marra; Mark G van Vledder; MingDe Lin; Michael A Choti; Danny Y Song; Allison M Okamura
Journal:  IEEE Trans Biomed Eng       Date:  2012-06-13       Impact factor: 4.538

7.  Design and Control of Concentric-Tube Robots.

Authors:  Pierre E Dupont; Jesse Lock; Brandon Itkowitz; Evan Butler
Journal:  IEEE Trans Robot       Date:  2010-04-01       Impact factor: 5.567

8.  Diagnostic yield of fiberoptic bronchoscopy in evaluating solitary pulmonary nodules.

Authors:  W A Baaklini; M A Reinoso; A B Gorin; A Sharafkaneh; P Manian
Journal:  Chest       Date:  2000-04       Impact factor: 9.410

9.  Hand-held transendoscopic robotic manipulators: A transurethral laser prostate surgery case study.

Authors:  Richard J Hendrick; Christopher R Mitchell; S Duke Herrell; Robert J Webster
Journal:  Int J Rob Res       Date:  2015-07-28       Impact factor: 4.703

10.  Percutaneous intracardiac beating-heart surgery using metal MEMS tissue approximation tools.

Authors:  Andrew H Gosline; Nikolay V Vasilyev; Evan J Butler; Chris Folk; Adam Cohen; Rich Chen; Nora Lang; Pedro J Del Nido; Pierre E Dupont
Journal:  Int J Rob Res       Date:  2012-08-01       Impact factor: 4.703

View more
  9 in total

1.  Transbronchial biopsy catheter enhanced by a multisection continuum robot with follow-the-leader motion.

Authors:  Lenny Dupourqué; Fumitaro Masaki; Yolonda L Colson; Takahisa Kato; Nobuhiko Hata
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-07-09       Impact factor: 2.924

Review 2.  Latest technology in minimally invasive thoracic surgery.

Authors:  Ivan Chi Hin Siu; Zheng Li; Calvin S H Ng
Journal:  Ann Transl Med       Date:  2019-01

3.  Decoupling Steerability from Diameter: Helical Dovetail Laser Patterning for Steerable Needles.

Authors:  Margaret Rox; Maxwell Emerson; Tayfun Efe Ertop; Inbar Fried; Mengyu Fu; Janine Hoelscher; Alan Kuntz; Josephine Granna; Jason Mitchell; Michael Lester; Fabien Maldonado; Erin A Gillaspie; Jason A Akulian; Ron Alterovitz; Robert J Webster
Journal:  IEEE Access       Date:  2020-10-02       Impact factor: 3.367

4.  Design and Control of a Compact, Modular Robot for Transbronchial Lung Biopsy.

Authors:  Stephanie Amack; Margaret Rox; Jason Mitchell; Tayfun Efe Ertop; Maxwell Emerson; Alan Kuntz; Fabien Maldonado; Jason Akulian; Joshua Gafford; Ron Alterovitz; Robert J Webster
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2019-03-08

5.  STEERABLE NEEDLE TRAJECTORY FOLLOWING IN THE LUNG: TORSIONAL DEADBAND COMPENSATION AND FULL POSE ESTIMATION WITH 5DOF FEEDBACK FOR NEEDLES PASSING THROUGH FLEXIBLE ENDOSCOPES.

Authors:  Tayfun Efe Ertop; Maxwell Emerson; Margaret Rox; Josephine Granna; Fabien Maldonado; Erin Gillaspie; Michael Lester; Alan Kuntz; Caleb Rucker; Mengyu Fu; Janine Hoelscher; Inbar Fried; Ron Alterovitz; Robert Webster
Journal:  Proc ASME Dyn Syst Control Conf       Date:  2020-10

6.  Design Considerations for a Steerable Needle Robot to Maximize Reachable Lung Volume.

Authors:  Inbar Fried; Janine Hoelscher; Mengyu Fu; Maxwell Emerson; Tayfun Efe Ertop; Margaret Rox; Josephine Granna; Alan Kuntz; Jason A Akulian; Robert J Webster; Ron Alterovitz
Journal:  IEEE Int Conf Robot Autom       Date:  2021-10-18

7.  Mathematical modeling and computer simulation of needle insertion into soft tissue.

Authors:  Adam Wittek; George Bourantas; Benjamin F Zwick; Grand Joldes; Lionel Esteban; Karol Miller
Journal:  PLoS One       Date:  2020-12-22       Impact factor: 3.240

8.  Backward Planning for a Multi-Stage Steerable Needle Lung Robot.

Authors:  Janine Hoelscher; Mengyu Fu; Inbar Fried; Maxwell Emerson; Tayfun Efe Ertop; Margaret Rox; Alan Kuntz; Jason A Akulian; Robert J Webster; Ron Alterovitz
Journal:  IEEE Robot Autom Lett       Date:  2021-03-17

9.  Bronchoscopic needle-based confocal laser endomicroscopy (nCLE) as a real-time detection tool for peripheral lung cancer.

Authors:  Tess Kramer; Lizzy Wijmans; Martijn de Bruin; Ton van Leeuwen; Teodora Radonic; Peter Bonta; Jouke T Annema
Journal:  Thorax       Date:  2021-06-25       Impact factor: 9.139

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.