Literature DB >> 26622208

Concentric Tube Robots as Steerable Needles: Achieving Follow-the-Leader Deployment.

Hunter B Gilbert1, Joseph Neimat2, Robert J Webster1.   

Abstract

Concentric tube robots can enable new clinical interventions if they are able to pass through soft tissue, deploy along desired paths through open cavities, or travel along winding lumens. These behaviors require the robot to deploy in such a way that the curved shape of its shaft remains unchanged as the tip progresses forward (i.e., "follow-the-leader" deployment). Follow-the-leader deployment is challenging for concentric tube robots due to elastic (and particularly torsional) coupling between the tubes that form the robot. However, as we show in this paper, follow-the-leader deployment is possible, provided that tube precurvatures and deployment sequences are appropriately selected. We begin by defining follow-the-leader deployment and providing conditions that must be satisfied for a concentric tube robot to achieve it. We then examine several useful special cases of follow-the-leader deployment, showing that both circular and helical precurvatures can be employed, and provide an experimental illustration of the helical case. We also explore approximate follow-the-leader behavior and provide a metric for the similarity of a general deployment to a follow-the-leader deployment. Finally, we consider access to the hippocampus in the brain to treat epilepsy, as a motivating clinical example for follow-the-leader deployment.

Entities:  

Keywords:  Concentric tube robot; continuum robot; medical robotics; needle steering; surgical robotics

Year:  2015        PMID: 26622208      PMCID: PMC4662566          DOI: 10.1109/TRO.2015.2394331

Source DB:  PubMed          Journal:  IEEE Trans Robot        ISSN: 1552-3098            Impact factor:   5.567


  15 in total

Review 1.  Needle insertion into soft tissue: a survey.

Authors:  Niki Abolhassani; Rajni Patel; Mehrdad Moallem
Journal:  Med Eng Phys       Date:  2006-08-28       Impact factor: 2.242

2.  An Autoclavable Steerable Cannula Manual Deployment Device: Design and Accuracy Analysis.

Authors:  Jessica Burgner; Philip J Swaney; Trevor L Bruns; Marlena S Clark; D Caleb Rucker; E Clif Burdette; Robert J Webster
Journal:  J Med Device       Date:  2012-11-21       Impact factor: 0.582

3.  A Geometrically Exact Model for Externally Loaded Concentric-Tube Continuum Robots.

Authors:  D Caleb Rucker; Bryan A Jones; Robert J Webster
Journal:  IEEE Trans Robot       Date:  2010       Impact factor: 5.567

4.  Equilibrium Conformations of Concentric-tube Continuum Robots.

Authors:  D Caleb Rucker; Robert J Webster; Gregory S Chirikjian; Noah J Cowan
Journal:  Int J Rob Res       Date:  2010-09-01       Impact factor: 4.703

5.  Real-time magnetic resonance-guided stereotactic laser amygdalohippocampotomy for mesial temporal lobe epilepsy.

Authors:  Jon T Willie; Nealen G Laxpati; Daniel L Drane; Ashok Gowda; Christina Appin; Chunhai Hao; Daniel J Brat; Sandra L Helmers; Amit Saindane; Sherif G Nour; Robert E Gross
Journal:  Neurosurgery       Date:  2014-06       Impact factor: 4.654

6.  Design and Control of Concentric-Tube Robots.

Authors:  Pierre E Dupont; Jesse Lock; Brandon Itkowitz; Evan Butler
Journal:  IEEE Trans Robot       Date:  2010-04-01       Impact factor: 5.567

7.  A Telerobotic System for Transnasal Surgery.

Authors:  Jessica Burgner; D Caleb Rucker; Hunter B Gilbert; Philip J Swaney; Paul T Russell; Kyle D Weaver; Robert J Webster
Journal:  IEEE ASME Trans Mechatron       Date:  2013-06-19       Impact factor: 5.303

8.  Extent of medial temporal resection on outcome from anterior temporal lobectomy: a randomized prospective study.

Authors:  A R Wyler; B P Hermann; G Somes
Journal:  Neurosurgery       Date:  1995-11       Impact factor: 4.654

9.  Motion Planning for Concentric Tube Robots Using Mechanics-based Models.

Authors:  Luis G Torres; Ron Alterovitz
Journal:  Rep U S       Date:  2011

10.  Percutaneous intracardiac beating-heart surgery using metal MEMS tissue approximation tools.

Authors:  Andrew H Gosline; Nikolay V Vasilyev; Evan J Butler; Chris Folk; Adam Cohen; Rich Chen; Nora Lang; Pedro J Del Nido; Pierre E Dupont
Journal:  Int J Rob Res       Date:  2012-08-01       Impact factor: 4.703

View more
  13 in total

1.  Toward Transoral Peripheral Lung Access: Combining Continuum Robots and Steerable Needles.

Authors:  Philip J Swaney; Arthur W Mahoney; Bryan I Hartley; Andria A Remirez; Erik Lamers; Richard H Feins; Ron Alterovitz; Robert J Webster
Journal:  J Med Robot Res       Date:  2016-10-11

2.  A Concentric Tube Continuum Robot with Piezoelectric Actuation for MRI-Guided Closed-Loop Targeting.

Authors:  Hao Su; Gang Li; D Caleb Rucker; Robert J Webster Iii; Gregory S Fischer
Journal:  Ann Biomed Eng       Date:  2016-03-16       Impact factor: 3.934

3.  Decoupling Steerability from Diameter: Helical Dovetail Laser Patterning for Steerable Needles.

Authors:  Margaret Rox; Maxwell Emerson; Tayfun Efe Ertop; Inbar Fried; Mengyu Fu; Janine Hoelscher; Alan Kuntz; Josephine Granna; Jason Mitchell; Michael Lester; Fabien Maldonado; Erin A Gillaspie; Jason A Akulian; Ron Alterovitz; Robert J Webster
Journal:  IEEE Access       Date:  2020-10-02       Impact factor: 3.367

4.  Targeting Epilepsy Through the Foremen Ovale: How Many Helical Needles are Needed?

Authors:  J Granna; E B Pitt; M E McKay; T J Ball; J S Neimat; D J Englot; R P Naftel; E J Barth; R J Webster
Journal:  Ann Biomed Eng       Date:  2022-03-04       Impact factor: 3.934

5.  A Prospective Randomized Comparative Study of Three Guided Bronchoscopic Approaches for Investigating Pulmonary Nodules: The PRECISION-1 Study.

Authors:  Lonny Yarmus; Jason Akulian; Momen Wahidi; Alex Chen; Jennifer P Steltz; Sam L Solomon; Diana Yu; Fabien Maldonado; Jose Cardenas-Garcia; Daniela Molena; Hans Lee; Anil Vachani
Journal:  Chest       Date:  2019-11-01       Impact factor: 9.410

6.  The First Interlaced Continuum Robot, Devised to Intrinsically Follow the Leader.

Authors:  Byungjeon Kang; Risto Kojcev; Edoardo Sinibaldi
Journal:  PLoS One       Date:  2016-02-25       Impact factor: 3.240

7.  The Memo Slide: An explorative study into a novel mechanical follow-the-leader mechanism.

Authors:  Paul Wj Henselmans; Stefan Gottenbos; Gerwin Smit; Paul Breedveld
Journal:  Proc Inst Mech Eng H       Date:  2017-11-10       Impact factor: 1.617

8.  A Continuum Robot and Control Interface for Surgical Assist in Fetoscopic Interventions.

Authors:  George Dwyer; Francois Chadebecq; Marcel Tella Amo; Christos Bergeles; Efthymios Maneas; Vijay Pawar; Emanuel Vander Poorten; Jan Deprest; Sebastien Ourselin; Paolo De Coppi; Tom Vercauteren; Danail Stoyanov
Journal:  IEEE Robot Autom Lett       Date:  2017-03-08

9.  Optimization of Curvilinear Needle Trajectories for Transforamenal Hippocampotomy.

Authors:  David B Comber; E Bryn Pitt; Hunter B Gilbert; Matthew W Powelson; Emily Matijevich; Joseph S Neimat; Robert J Webster; Eric J Barth
Journal:  Oper Neurosurg (Hagerstown)       Date:  2016-07-25       Impact factor: 2.703

10.  Needle placement errors: do we need steerable needles in interventional radiology?

Authors:  Tonke L de Jong; Nick J van de Berg; Lisette Tas; Adriaan Moelker; Jenny Dankelman; John J van den Dobbelsteen
Journal:  Med Devices (Auckl)       Date:  2018-08-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.