Literature DB >> 28475021

Individualized 3D printed model-assisted posterior screw fixation for the treatment of craniovertebral junction abnormality: a retrospective study.

Fangyou Gao1, Qu Wang1, Chuangxi Liu1, Bing Xiong1, Tao Luo1.   

Abstract

OBJECTIVE This study was undertaken to evaluate the feasibility and efficacy of individualized 3D printed model-assisted posterior internal fixation in treating craniovertebral junction (CVJ) abnormalities. METHODS Forty-four patients (19 males and 25 females; mean age 36.5 ± 9.2 years, range 11-62 years; symptom duration 1 month-15 years) with a CVJ abnormality who were admitted to the authors' institution between April 2010 and April 2015 were retrospectively studied. The individualized 3D printed model of the CVJ was produced based on the individual CT data by use of 3D printing technology. The posterior internal fixation was simulated on the model to obtain data for individual patients, which were then used for intraoperative assistance. One-stage posterior decompression combined with internal fixation was performed. The results were evaluated using the Japanese Orthopaedic Association (JOA) scale, atlanto-dens interval (ADI), and cervicomedullary angle (CMA). The patients underwent follow-up and outcomes were evaluated using CT, MRI, and the JOA scale score. The comparison between preoperative and postoperative JOA scale scores was done using a paired t-test. RESULTS Thirty-eight individualized 3D printed models were successfully built. The 38 patients underwent successful posterior internal fixation performed with the assistance of 3D printed models. In the 6 patients without an individualized printed model (i.e., the patients who underwent surgery before 3D printed modeling was available at the authors' institution), the pedicle screw was inserted incorrectly into the transverse foramen in 2 patients and inserted incorrectly into the vertebral canal in 1 patient. All patients were observed for a mean of 26 months (range 3-52 months). The postoperative JOA scale scores for all patients significantly improved from the preoperative scores. Among the 41 patients treated with atlantoaxial distraction reduction, postoperative MRI and CT showed complete reduction in 31 patients and incomplete reduction in 10 patients (reduction rate > 50%). The postoperative ADI significantly decreased, and the CMA significantly increased. CONCLUSIONS Individualized 3D printed model-assisted posterior internal fixation seems feasible and effective in optimizing the treatment of CVJ abnormalities. In addition, it offers many advantages, including preoperative simulation, intraoperatve guidance, and intraoperative error minimization.

Entities:  

Keywords:  3D printed model; AAD = atlantoaxial dislocation; ADI = atlanto-dens interval; AOA = atlantooccipital assimilation; CMA = cervicomedullary angle; CVJ = craniovertebral junction; JOA = Japanese Orthopaedic Association; VA = vertebral artery; atlantoaxial dislocation; craniovertebral junction abnormality; internal fixation; surgical technique

Mesh:

Year:  2017        PMID: 28475021     DOI: 10.3171/2016.11.SPINE16713

Source DB:  PubMed          Journal:  J Neurosurg Spine        ISSN: 1547-5646


  6 in total

Review 1.  3-dimensional printing for anterior cervical surgery: a review.

Authors:  Wen Jie Choy; William C H Parr; Kevin Phan; William R Walsh; Ralph J Mobbs
Journal:  J Spine Surg       Date:  2018-12

Review 2.  3D printing applications in spine surgery: an evidence-based assessment toward personalized patient care.

Authors:  Ahmed Habib; Nicolina Jovanovich; Nallammai Muthiah; Ali Alattar; Nima Alan; Nitin Agarwal; Alp Ozpinar; David Kojo Hamilton
Journal:  Eur Spine J       Date:  2022-05-19       Impact factor: 2.721

3.  Three-Dimensional-Printed Drill Guides for Occipitothoracic Fusion in a Pediatric Patient With Occipitocervical Instability.

Authors:  Peter A J Pijpker; Jos M A Kuijlen; Bart L Kaptein; Willem Pondaag
Journal:  Oper Neurosurg (Hagerstown)       Date:  2021-06-15       Impact factor: 2.703

4.  Application of 3-dimensional printing technology combined with guide plates for thoracic spinal tuberculosis.

Authors:  Yifan Wang; Shiyuan Shi; Qi Zheng; Yanghui Jin; Yingjie Dai
Journal:  Medicine (Baltimore)       Date:  2021-02-12       Impact factor: 1.817

5.  Prediction of the functional and radiological outcome on the basis of independent factors with special emphasis on the use of 3D printed models in craniovertebral junction surgery.

Authors:  Rashim Kataria; Mudit Mehrotra; Devendra Kumar Purohit; Ajay Gupta; Monika Rathore
Journal:  Surg Neurol Int       Date:  2022-08-19

6.  Application of 3D printed model for planning the endoscopic endonasal transsphenoidal surgery.

Authors:  Xing Huang; Ni Fan; Hai-Jun Wang; Yan Zhou; Xudong Li; Xiao-Bing Jiang
Journal:  Sci Rep       Date:  2021-03-05       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.