Literature DB >> 28470795

Multispectral diffusion-weighted imaging near metal implants.

Kevin M Koch1, Sampada Bhave1, Ajeet Gaddipati2, Brian A Hargreaves3, Dawei Gui2, Robert Peters2, Meena Bedi4, Rajeev Mannem1, S Sivaram Kaushik2.   

Abstract

PURPOSE: The need for diffusion-weighted-imaging (DWI) near metallic implants is becoming increasingly relevant for a variety of clinical diagnostic applications. Conventional DWI methods are significantly hindered by metal-induced image artifacts. A novel approach relying on multispectral susceptibility artifact reduction techniques is presented to address this unmet need.
METHODS: DWI near metal implants is achieved through a combination of several advanced MRI acquisition technologies. Previously described approaches to Carr-Purcell-Meiboom-Gill spin-echo train DWI sequences using the periodically rotated overlapping parallel lines with enhanced reconstruction are combined with multispectral-imaging metal artifact reduction principles to provide DWI with substantially reduced artifact levels. The presented methods are applied to limited sets of slices over areas of sarcoma risk near six implanted devices.
RESULTS: Using the presented methods, DWI assessment without bulk image distortions is demonstrated in the immediate vicinity of metallic interfaces. In one subject, the apparent diffusion coefficient was reduced in a region of suspected sarcoma directly adjacent to fixation hardware.
CONCLUSIONS: An initial demonstration of minimal-artifact multispectral DWI in the near vicinity of metallic hardware is described and successfully demonstrated on clinical subjects. Magn Reson Med 79:987-993, 2018.
© 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  PROPELLER; diffusion-weighted imaging; metal implants; multispectral-imaging

Mesh:

Substances:

Year:  2017        PMID: 28470795     DOI: 10.1002/mrm.26737

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

1.  Volumetric and multispectral DWI near metallic implants using a non-linear phase Carr-Purcell-Meiboom-Gill diffusion preparation.

Authors:  Philip K Lee; Daehyun Yoon; Jesse K Sandberg; Shreyas S Vasanawala; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2022-01-11       Impact factor: 4.668

2.  Influence of angioplasty and stenting on intracranial artery stenosis: preliminary results of high-resolution vessel wall imaging evaluation.

Authors:  Chia-Hung Wu; Chih-Ping Chung; Ting-Yi Chen; Kai-Wei Yu; Te-Ming Lin; Wei-An Tai; Chao-Bao Luo; Feng-Chi Chang
Journal:  Eur Radiol       Date:  2022-07-19       Impact factor: 7.034

3.  Multispectral diffusion-weighted MRI of the instrumented cervical spinal cord: a preliminary study of 5 cases.

Authors:  Kevin M Koch; Sampada Bhave; S Sivaram Kaushik; Andrew S Nencka; Matthew D Budde
Journal:  Eur Spine J       Date:  2019-12-12       Impact factor: 3.134

Review 4.  Current advances in the imaging of atherosclerotic vulnerable plaque using nanoparticles.

Authors:  Ming Zhang; Zhongjian Xie; Haijiao Long; Kun Ren; Lianjie Hou; Yu Wang; Xiaodan Xu; Weixing Lei; Zhicheng Yang; Shakeel Ahmed; Han Zhang; Guojun Zhao
Journal:  Mater Today Bio       Date:  2022-03-07

5.  Filter-probe diffusion imaging improves spinal cord injury outcome prediction.

Authors:  Nathan P Skinner; Seung-Yi Lee; Shekar N Kurpad; Brian D Schmit; L Tugan Muftuler; Matthew D Budde
Journal:  Ann Neurol       Date:  2018-07-03       Impact factor: 11.274

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.