Literature DB >> 28461802

Nonidentical Continuous-Flow Devices For Biventricular Support.

Andrew C W Baldwin, Elena Sandoval, William E Cohn, Hari R Mallidi, Jeffrey A Morgan, O H Frazier.   

Abstract

Although biventricular heart failure has been successfully managed with dual continuous-flow ventricular assist devices, the long-term use of 2 mechanically dissimilar pumps has traditionally been discouraged. We present the case of a 52-year-old man whose treatment with a HeartMate II left ventricular assist device was complicated by right ventricular failure, necessitating the implantation of a long-term right ventricular assist device. A HeartWare left ventricular assist device was placed along the right ventricular base to avoid interference with the HeartMate II housing. The patient was discharged from the hospital after routine postoperative care and dual-device training. This case shows that, despite logistical complexities, nonidentical continuous-flow device pairings can successfully provide long-term biventricular support.

Entities:  

Keywords:  Assisted circulation/instrumentation; heart failure/therapy; heart-assist devices; recovery of function; treatment outcome; ventricular dysfunction, left therapy; ventricular dysfunction, right therapy

Mesh:

Year:  2017        PMID: 28461802      PMCID: PMC5408630          DOI: 10.14503/THIJ-16-5878

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  6 in total

1.  Biventricular assistance with the Jarvik FlowMaker: a case report.

Authors:  O H Frazier; Timothy J Myers; Igor Gregoric
Journal:  J Thorac Cardiovasc Surg       Date:  2004-10       Impact factor: 5.209

2.  Successful use of the HeartWare HVAD rotary blood pump for biventricular support.

Authors:  Martin Strueber; Anna L Meyer; Doris Malehsa; Axel Haverich
Journal:  J Thorac Cardiovasc Surg       Date:  2010-05-15       Impact factor: 5.209

3.  Sixth INTERMACS annual report: a 10,000-patient database.

Authors:  James K Kirklin; David C Naftel; Francis D Pagani; Robert L Kormos; Lynne W Stevenson; Elizabeth D Blume; Marissa A Miller; J T Baldwin; J Timothy Baldwin; James B Young
Journal:  J Heart Lung Transplant       Date:  2014-04-21       Impact factor: 10.247

4.  Initial clinical experience of total cardiac replacement with dual HeartMate-II axial flow pumps for severe biventricular heart failure.

Authors:  Matthias Loebe; Brian Bruckner; Michael J Reardon; Erika van Doorn; Jerry Estep; Igor Gregoric; Faisel Masud; William Cohn; Tadashi Motomura; Guillermo Torre-Amione; O H Frazier
Journal:  Methodist Debakey Cardiovasc J       Date:  2011 Jan-Mar

5.  The sandwich plug technique: simple, effective, and rapid closure of a mechanical aortic valve prosthesis at left ventricular assist device implantation.

Authors:  William E Cohn; O H Frazier
Journal:  J Thorac Cardiovasc Surg       Date:  2011-02-01       Impact factor: 5.209

6.  Biventricular circulatory support with two miniaturized implantable assist devices.

Authors:  Thomas Krabatsch; Evgenij Potapov; Alexander Stepanenko; Martin Schweiger; Marian Kukucka; Michael Huebler; Ewald Hennig; Roland Hetzer
Journal:  Circulation       Date:  2011-09-13       Impact factor: 29.690

  6 in total
  1 in total

1.  Comparison of SynCardia total artificial heart and HeartWare HVAD biventricular support for management of biventricular heart failure: a systematic review and meta-analysis.

Authors:  Elizabeth J Maynes; Thomas J O'Malley; Jessica G Y Luc; Matthew P Weber; Dylan P Horan; Jae Hwan Choi; Sinal Patel; Syed-Saif Abbas Rizvi; Rohinton J Morris; John W Entwistle; H Todd Massey; Vakhtang Tchantchaleishvili
Journal:  Ann Cardiothorac Surg       Date:  2020-03
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.