Literature DB >> 28457265

Anatomic landmarks and availability of bone for placement of orthodontic mini-implants for normal and short maxillary body lengths.

Jan Hourfar1, Dirk Bister2, Christopher J Lux3, Bouthayna Al-Tamimi4, Björn Ludwig5.   

Abstract

INTRODUCTION: Increasing numbers of orthodontic mini-implants are placed in the anterior maxilla. To our knowledge, bone levels and root proximity of patients with cephalometrically short maxillae have not been investigated before. The first, second, and third rugae were used as clinical reference lines, and the aim of this study was to measure bone availability in that area by comparing patients with short and normal maxillary body lengths.
METHODS: The sample consisted of 21 patients in each group: short maxillary body length and normal maxillary body length. The patients' study models were bisected, and the outline of the palatal contour was marked on the surface. The models were scanned, and the palatal contours were superimposed on the palatal structures of their respective initial cephalometric headfilms, and the vertical and oblique bone levels of the sagittal plane were compared using the Student t test. The level of significance was set at P <0.05.
RESULTS: Compared with maxillae of normal maxillary body length, less bone was available in maxillae of short maxillary body length. However, the differences did not reach clinical or statistical significance (P >0.05) at the third rugae.
CONCLUSIONS: Almost equivalent average bone depth at the third rugae in patients with normal and short maxillary body lengths suggests that this site can be used for 8-mm long obliquely inserted orthodontic mini-implants.
Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2017        PMID: 28457265     DOI: 10.1016/j.ajodo.2016.09.024

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  2 in total

1.  Insertion torque values and success rates for paramedian insertion of orthodontic mini-implants : A retrospective study.

Authors:  Bruno Di Leonardo; Björn Ludwig; Jörg Alexander Lisson; Luca Contardo; Rossano Mura; Jan Hourfar
Journal:  J Orofac Orthop       Date:  2018-02-20       Impact factor: 1.938

2.  Evaluation of Palatal Bone Thickness and Its Relationship with Palatal Vault Depth for Mini-Implant Insertion Using Cone Beam Computed Tomography Images.

Authors:  Gholinia Faegheh; Negar Khosravifard; Dina Maleki; Sahar Khaje Hosseini
Journal:  Turk J Orthod       Date:  2022-06
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.