Literature DB >> 28437133

The impact of the centrifuge characteristics and centrifugation protocols on the cells, growth factors, and fibrin architecture of a leukocyte- and platelet-rich fibrin (L-PRF) clot and membrane.

David M Dohan Ehrenfest1,2, Nelson R Pinto3,4, Andrea Pereda3, Paula Jiménez3, Marco Del Corso5, Byung-Soo Kang6, Mauricio Nally3, Nicole Lanata7, Hom-Lay Wang8, Marc Quirynen4.   

Abstract

L-PRF (leukocyte- and platelet-rich fibrin) is one of the four families of platelet concentrates for surgical use and is widely used in oral and maxillofacial regenerative therapies. The first objective of this article was to evaluate the mechanical vibrations appearing during centrifugation in four models of commercially available table-top centrifuges used to produce L-PRF and the impact of the centrifuge characteristics on the cell and fibrin architecture of a L-PRF clot and membrane. The second objective of this article was to evaluate how changing some parameters of the L-PRF protocol may influence its biological signature, independently from the characteristics of the centrifuge. In the first part, four different commercially available centrifuges were used to produce L-PRF, following the original L-PRF production method (glass-coated plastic tubes, 400 g force, 12 minutes). The tested systems were the original L-PRF centrifuge (Intra-Spin, Intra-Lock, the only CE and FDA cleared system for the preparation of L-PRF) and three other laboratory centrifuges (not CE/FDA cleared for L-PRF): A-PRF 12 (Advanced PRF, Process), LW-UPD8 (LW Scientific) and Salvin 1310 (Salvin Dental). Each centrifuge was opened for inspection, two accelerometers were installed (one radial, one vertical), and data were collected with a spectrum analyzer in two configurations (full-load or half load). All clots and membranes were collected into a sterile surgical box (Xpression kit, Intra-Lock). The exact macroscopic (weights, sizes) and microscopic (photonic and scanning electron microscopy SEM) characteristics of the L-PRF produced with these four different machines were evaluated. In the second part, venous blood was taken in two groups, respectively, Intra-Spin 9 ml glass-coated plastic tubes (Intra-Lock) and A-PRF 10 ml glass tubes (Process). Tubes were immediately centrifuged at 2700 rpm (around 400 g) during 12 minutes to produce L-PRF or at 1500 rpm during 14 minutes to produce A-PRF. All centrifugations were done using the original L-PRF centrifuge (Intra-Spin), as recommended by the two manufacturers. Half of the membranes were placed individually in culture media and transferred in a new tube at seven experimental times (up to 7 days). The releases of transforming growth factor β-1 (TGFβ-1), platelet derived growth factor AB (PDGF-AB), vascular endothelial growth factor (VEGF) and bone morphogenetic protein 2 (BMP-2) were quantified using ELISA kits at these seven experimental times. The remaining membranes were used to evaluate the initial quantity of growth factors of the L-PRF and A-PRF membranes, through forcible extraction. Very significant differences in the level of vibrations at each rotational speed were observed between the four tested centrifuges. The original L-PRF centrifuge (Intra-Spin) was by far the most stable machine in all configurations and always remained under the threshold of resonance, unlike the three other tested machines. At the classical speed of production of L-PRF, the level of undesirable vibrations on the original centrifuge was between 4.5 and 6 times lower than with other centrifuges. Intra-Spin showed the lowest temperature of the tubes. A-PRF and Salvin were both associated with a significant increase in temperature in the tube. Intra-Spin produced the heaviest clot and quantity of exudate among the four techniques. A-PRF and LW produced much lighter, shorter and narrower clots and membranes than the two other centrifuges. Light microscopy analysis showed relatively similar features for all L-PRF types (concentration of cell bodies in the first half). However, SEM illustrated considerable differences between samples. The original Intra-Spin L-PRF showed a strongly polymerized thick fibrin matrix and all cells appeared alive with a normal shape, including the textured surface aspect of activated lymphocytes. The A-PRF, Salvin and LW PRF-like membranes presented a lightly polymerized slim fibrin gel and most of the visible cell bodies appeared destroyed (squashed or shrunk). In the second part of this study, the slow release of the three tested growth factors from original L-PRF membranes was significantly stronger (more than twice stronger, p<0.001) at all experimental times than the release from A-PRF membranes. No trace of BMP2 could be detected in the A-PRF. A slow release of BMP2 was detected during at least 7 days in the original L-PRF. Moreover, the original L-PRF clots and membranes (produced with 9 mL blood) were always significantly larger than the A-PRF (produced with 10 mL blood). The A-PRF membranes dissolved in vitro after less than 3 days, while the L-PRF membrane remained in good shape during at least 7 days. Each centrifuge has its clear own profile of vibrations depending on the rotational speed, and the centrifuge characteristics are directly impacting the architecture and cell content of a L-PRF clot. This result may reveal a considerable flaw in all the PRP/PRF literature, as this parameter was never considered. The original L-PRF clot (Intra-Spin) presented very specific characteristics, which appeared distorted when using centrifuges with a higher vibration level. A-PRF, LW and Salvin centrifuges produced PRF-like materials with a damaged and almost destroyed cell population through the standard protocol, and it is therefore impossible to classify these products in the L-PRF family. Moreover, when using the same centrifuge, the original L-PRF protocol allowed producing larger clots/membranes and a more intense release of growth factors (biological signature at least twice stronger) than the modified A-PRF protocol. Both protocols are therefore significantly different, and the clinical and experimental results from the original L-PRF shall not be extrapolated to the A-PRF. Finally, the comparison between the total released amounts and the initial content of the membrane (after forcible extraction) highlighted that the leukocytes living in the fibrin matrix are involved in the production of significant amounts of growth factors. The centrifuge characteristics and centrifugation protocols impact significantly and dramatically the cells, growth factors and fibrin architecture of L-PRF.

Entities:  

Keywords:  Blood platelets; growth factors; leukocytes; platelet-rich plasma; regenerative medicine; wound healing

Mesh:

Substances:

Year:  2017        PMID: 28437133     DOI: 10.1080/09537104.2017.1293812

Source DB:  PubMed          Journal:  Platelets        ISSN: 0953-7104            Impact factor:   3.862


  59 in total

1.  Striking Differences in Platelet Distribution between Advanced-Platelet-Rich Fibrin and Concentrated Growth Factors: Effects of Silica-Containing Plastic Tubes.

Authors:  Tetsuhiro Tsujino; Hideo Masuki; Masayuki Nakamura; Kazushige Isobe; Hideo Kawabata; Hachidai Aizawa; Taisuke Watanabe; Yutaka Kitamura; Hajime Okudera; Kazuhiro Okuda; Koh Nakata; Tomoyuki Kawase
Journal:  J Funct Biomater       Date:  2019-09-17

2.  PRF improves wound healing and postoperative discomfort after harvesting subepithelial connective tissue graft from palate: a randomized controlled trial.

Authors:  Aysan Lektemur Alpan; Gizem Torumtay Cin
Journal:  Clin Oral Investig       Date:  2019-05-18       Impact factor: 3.573

3.  New Biomaterials and Regenerative Medicine Strategies in Periodontology, Oral Surgery, Esthetic and Implant Dentistry 2018.

Authors:  David M Dohan Ehrenfest; Adriano Piattelli; Gilberto Sammartino; Hom-Lay Wang
Journal:  Biomed Res Int       Date:  2019-12-04       Impact factor: 3.411

4.  The impact of gender and peripheral blood parameters on the characteristics of L-PRF membranes.

Authors:  Catherine Andrade Aldana; Felipe Ugarte Amenabar; Carolina Inostroza Silva; Paulo Diaz Calderon; David Rosenberg Messina; Nelson Pinto Carrasco; Marc Quirynen
Journal:  J Oral Biol Craniofac Res       Date:  2022-09-01

5.  Clinical evaluation of coronally advanced flap with or without platelet-rich fibrin for the treatment of multiple gingival recessions.

Authors:  Samed Kuka; Sebnem Dirikan Ipci; Gokser Cakar; Selcuk Yılmaz
Journal:  Clin Oral Investig       Date:  2017-10-20       Impact factor: 3.573

Review 6.  [Research progress on platelet-rich fibrin derivatives].

Authors:  Yao-Ren Chang; Chun Liu; Li-Hua Yin
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2019-12-01

Review 7.  A Comprehensive Review of Concentrated Growth Factors and Their Novel Applications in Facial Reconstructive and Regenerative Medicine.

Authors:  Jianguo Chen; Haiyue Jiang
Journal:  Aesthetic Plast Surg       Date:  2020-01-22       Impact factor: 2.326

8.  The use of platelet-rich fibrin with platelet-rich plasma support meniscal repair surgery.

Authors:  Masahiko Kemmochi; Shigeru Sasaki; Masako Takahashi; Tomitaka Nishimura; Chisa Aizawa; Jun Kikuchi
Journal:  J Orthop       Date:  2018-05-15

Review 9.  Is the use of platelet-rich fibrin effective in the healing, control of pain, and postoperative bleeding in the palatal area after free gingival graft harvesting? A systematic review of randomized clinical studies.

Authors:  Jonathan Meza-Mauricio; Camila Pinheiro Furquim; Antonella Geldres; Gerardo Mendoza-Azpur; Belen Retamal-Valdes; Vittorio Moraschini; Marcelo Faveri
Journal:  Clin Oral Investig       Date:  2021-04-07       Impact factor: 3.573

10.  Impact of g force and timing on the characteristics of platelet-rich fibrin matrices.

Authors:  Ana B Castro; C Andrade; X Li; N Pinto; W Teughels; M Quirynen
Journal:  Sci Rep       Date:  2021-03-16       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.