Literature DB >> 28432656

Collisional Cross-Sections with T-Wave Ion Mobility Spectrometry without Experimental Calibration.

Daniel N Mortensen1, Anna C Susa1, Evan R Williams2.   

Abstract

A method for relating traveling-wave ion mobility spectrometry (TWIMS) drift times with collisional cross-sections using computational simulations is presented. This method is developed using SIMION modeling of the TWIMS potential wave and equations that describe the velocity of ions in gases induced by electric fields. The accuracy of this method is assessed by comparing the collisional cross-sections of 70 different reference ions obtained using this method with those obtained from static drift tube ion mobility measurements. The cross-sections obtained here with low wave velocities are very similar to those obtained using static drift (average difference = 0.3%) for ions formed from both denaturing and buffered aqueous solutions. In contrast, the cross-sections obtained with high wave velocities are significantly greater, especially for ions formed from buffered aqueous solutions. These higher cross-sections at high wave velocities may result from high-order factors not accounted for in the model presented here or from the protein ions unfolding during TWIMS. Results from this study demonstrate that collisional cross-sections can be obtained from single TWIMS drift time measurements, but that low wave velocities and gentle instrument conditions should be used in order to minimize any uncertainties resulting from high-order effects not accounted for in the present model and from any protein unfolding that might occur. Thus, the method presented here eliminates the need to calibrate TWIMS drift times with collisional cross-sections measured using other ion mobility devices. Graphical Abstract ᅟ.

Keywords:  Collisional cross-sections; Ion mobility; Mass spectrometry; Traveling wave

Year:  2017        PMID: 28432656     DOI: 10.1007/s13361-017-1669-0

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  38 in total

1.  Two-dimensional gas-phase separations coupled to mass spectrometry for analysis of complex mixtures.

Authors:  Keqi Tang; Fumin Li; Alexandre A Shvartsburg; Eric F Strittmatter; Richard D Smith
Journal:  Anal Chem       Date:  2005-10-01       Impact factor: 6.986

2.  Multidimensional separations of ubiquitin conformers in the gas phase: relating ion cross sections to H/D exchange measurements.

Authors:  Errol W Robinson; Evan R Williams
Journal:  J Am Soc Mass Spectrom       Date:  2005-09       Impact factor: 3.109

Review 3.  Ion mobility-mass spectrometry.

Authors:  Abu B Kanu; Prabha Dwivedi; Maggie Tam; Laura Matz; Herbert H Hill
Journal:  J Mass Spectrom       Date:  2008-01       Impact factor: 1.982

4.  Ion mobility-mass spectrometry analysis of large protein complexes.

Authors:  Brandon T Ruotolo; Justin L P Benesch; Alan M Sandercock; Suk-Joon Hyung; Carol V Robinson
Journal:  Nat Protoc       Date:  2008-06-19       Impact factor: 13.491

5.  Characterization of phosphorylated peptides using traveling wave-based and drift cell ion mobility mass spectrometry.

Authors:  Konstantinos Thalassinos; Megan Grabenauer; Susan E Slade; Gillian R Hilton; Michael T Bowers; James H Scrivens
Journal:  Anal Chem       Date:  2009-01-01       Impact factor: 6.986

6.  The Influence of Drift Gas Composition on the Separation Mechanism in Traveling Wave Ion Mobility Spectrometry: Insight from Electrodynamic Simulations.

Authors:  Jody C May; John A McLean
Journal:  Int J Ion Mobil Spectrom       Date:  2003-06-01

7.  On-tissue protein identification and imaging by MALDI-ion mobility mass spectrometry.

Authors:  Jonathan Stauber; Luke MacAleese; Julien Franck; Emmanuelle Claude; Marten Snel; Basak Kükrer Kaletas; Ingrid M V D Wiel; Maxence Wisztorski; Isabelle Fournier; Ron M A Heeren
Journal:  J Am Soc Mass Spectrom       Date:  2009-09-29       Impact factor: 3.109

Review 8.  The power of ion mobility-mass spectrometry for structural characterization and the study of conformational dynamics.

Authors:  Francesco Lanucara; Stephen W Holman; Christopher J Gray; Claire E Eyers
Journal:  Nat Chem       Date:  2014-04       Impact factor: 24.427

9.  Traveling-wave ion mobility mass spectrometry of protein complexes: accurate calibrated collision cross-sections of human insulin oligomers.

Authors:  Rune Salbo; Matthew F Bush; Helle Naver; Iain Campuzano; Carol V Robinson; Ingrid Pettersson; Thomas J D Jørgensen; Kim F Haselmann
Journal:  Rapid Commun Mass Spectrom       Date:  2012-05-30       Impact factor: 2.419

10.  Gas-phase ion chromatography: transition metal state selection and carbon cluster formation.

Authors:  M T Bowers; P R Kemper; G von Helden; P A van Koppen
Journal:  Science       Date:  1993-06-04       Impact factor: 47.728

View more
  5 in total

1.  Evaluation of Waveform Profiles for Traveling Wave Ion Mobility Separations in Structures for Lossless Ion Manipulations.

Authors:  Christopher R Conant; Isaac K Attah; Sandilya V B Garimella; Gabe Nagy; Aivett Bilbao; Richard D Smith; Yehia M Ibrahim
Journal:  J Am Soc Mass Spectrom       Date:  2020-10-30       Impact factor: 3.109

2.  Collision Cross Sections of Charge-Reduced Proteins and Protein Complexes: A Database for Collision Cross Section Calibration.

Authors:  Alyssa Q Stiving; Benjamin J Jones; Jakub Ujma; Kevin Giles; Vicki H Wysocki
Journal:  Anal Chem       Date:  2020-02-27       Impact factor: 6.986

3.  Experimental Determination of Activation Energies for Covalent Bond Formation via Ion/Ion Reactions and Competing Processes.

Authors:  Melanie Cheung See Kit; Samantha O Shepherd; James S Prell; Ian K Webb
Journal:  J Am Soc Mass Spectrom       Date:  2021-03-17       Impact factor: 3.262

Review 4.  The Role of Mass Spectrometry in Structural Studies of Flavin-Based Electron Bifurcating Enzymes.

Authors:  Monika Tokmina-Lukaszewska; Angela Patterson; Luke Berry; Liam Scott; Narayanaganesh Balasubramanian; Brian Bothner
Journal:  Front Microbiol       Date:  2018-07-05       Impact factor: 5.640

Review 5.  Recommendations for reporting ion mobility Mass Spectrometry measurements.

Authors:  Valérie Gabelica; Alexandre A Shvartsburg; Carlos Afonso; Perdita Barran; Justin L P Benesch; Christian Bleiholder; Michael T Bowers; Aivett Bilbao; Matthew F Bush; J Larry Campbell; Iain D G Campuzano; Tim Causon; Brian H Clowers; Colin S Creaser; Edwin De Pauw; Johann Far; Francisco Fernandez-Lima; John C Fjeldsted; Kevin Giles; Michael Groessl; Christopher J Hogan; Stephan Hann; Hugh I Kim; Ruwan T Kurulugama; Jody C May; John A McLean; Kevin Pagel; Keith Richardson; Mark E Ridgeway; Frédéric Rosu; Frank Sobott; Konstantinos Thalassinos; Stephen J Valentine; Thomas Wyttenbach
Journal:  Mass Spectrom Rev       Date:  2019-02-01       Impact factor: 10.946

  5 in total