Literature DB >> 28432459

Using an anatomically preshaped low-profile locking plate system leads to reliable results in comminuted radial head fractures.

Moritz Crönlein1, Michael Zyskowski2, Marc Beirer2, Florian B Imhoff3, Dominik Pförringer2, Gunther H Sandmann4, Chlodwig Kirchhoff2, Peter Biberthaler2, Sebastian Siebenlist2,3.   

Abstract

INTRODUCTION: For comminuted and displaced fractures of the radial head open reduction and internal fixation (ORIF) is recommended nowadays as the treatment of choice. Due to the development of locking plates the possibilities of ORIF in complex fracture types were extended. The purpose of this retrospective survey therefore was to review the preliminary subjective and objective results in patients treated by anatomically preshaped locked plating. A reliable fracture healing for these recently introduced plating devices was hypothesized.
MATERIALS AND METHODS: Subjective and objective criteria included patient's satisfaction, pain rating on a visual analogue scale (VAS) and active range of motion (ROM) compared to the contralateral armside. Functional scoring included the Morrey elbow performance score (MEPS), the QuickDASH and the elbow self-assessment score (ESAS). Furthermore, follow-up radiographs were reviewed.
RESULTS: Between 2011 and 2014 a total of 24 patients were managed with ORIF using anatomically preshaped low-profile locking plates. All patients had suffered from comminuted radial head fractures (type III-IV according to Mason classification). Twenty of 24 patients returned for follow-up examination after a mean of 30 months (range 18-53 months). Patients' satisfaction was rated as highly satisfied in 17 cases and satisfied in 3 cases. An unrestricted ROM for extension-flexion arc and pronation-supination arc was rated in 10 cases. Minor ROM deficiencies with a 5° limited extension compared to the contralateral side was evaluated in 6 cases. Only four patients were rated with and extension and supination deficiency of 10°, one of whom with an additional pronation deficiency of 10°. The calculated MEPS was Ø 98 ± 4 (range 85-100), and the QuickDASH was Ø 3 ± 6 (range 0-21). The ESAS was completed by 18 patients with a mean of Ø 96.54 ± 2.95 (range 94-100) indicating a non-restricted elbow function.
CONCLUSIONS: The treatment of comminuted radial head fractures using anatomically preshaped locking radial head plates represents a reliable and safe surgical approach, leading to good to excellent functional results. Being aware of the importance of the radial head for elbow stability, open reduction and internal fixation should be preferred prior to radial head resection or replacement in complex radial head fractures. Further trials with a higher number of patients are needed to confirm the advantages of preshaped radial head plates.

Entities:  

Keywords:  Comminuted radial head fractures; Fracture treatment; Low-profile locking plates; Radial head fractures; Radial head plates

Mesh:

Year:  2017        PMID: 28432459     DOI: 10.1007/s00402-017-2693-z

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  6 in total

Review 1.  [Elbow dislocation fractures].

Authors:  S Siebenlist; K F Braun
Journal:  Unfallchirurg       Date:  2017-07       Impact factor: 1.000

Review 2.  [Importance of self-assessment in functional evaluation of trauma patients].

Authors:  M Beirer; P Biberthaler
Journal:  Unfallchirurg       Date:  2018-12       Impact factor: 1.000

3.  Polyaxial locking plates in treating distal humeral fractures: a comparative randomized trial for clinical outcome.

Authors:  Moritz Crönlein; Martin Lucke; Marc Beirer; Dominik Pförringer; Chlodwig Kirchhoff; Peter Biberthaler; Karl F Braun; Sebastian Siebenlist
Journal:  BMC Musculoskelet Disord       Date:  2017-12-28       Impact factor: 2.362

4.  Use of surgical glue for Mason type III radial head fractures: A case report.

Authors:  Da-Wei Chen; Wan-Kun Hu; Jia-Qian Zhou
Journal:  Medicine (Baltimore)       Date:  2019-05       Impact factor: 1.817

5.  Is early full weight bearing safe following locking plate ORIF of distal fibula fractures?

Authors:  Michael Zyskowski; Markus Wurm; Frederik Greve; Sebastian Pesch; Francesca von Matthey; Patrick Pflüger; Moritz Crönlein; Peter Biberthaler; Chlodwig Kirchhoff
Journal:  BMC Musculoskelet Disord       Date:  2021-02-09       Impact factor: 2.362

6.  Does implant removal of superior clavicle plate osteosynthesis affect the functional outcome: a prospective trial.

Authors:  Chlodwig Kirchhoff; Moritz Crönlein; Markus Wurm; Marc Beirer; Michael Zyskowski; Christopher Völk; Arthur Schwarz; Peter Biberthaler
Journal:  Arch Orthop Trauma Surg       Date:  2020-11-01       Impact factor: 3.067

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.