Safety and efficacy of pulmonary vein isolation using a surround flow catheter with contact force measurement capabilities: A multicenter registry.

Giuseppe Stabile1, Paolo Di Donna2, Vincenzo Schillaci3, Antonio Di Monaco4, Assunta Iuliano1, Domenico Caponi2, Francesco Urraro3, Francesco Solimene3, Massimo Grimaldi4, Marco Scaglione2.   

Abstract

INTRODUCTION: Pulmonary vein (PV) isolation is the cornerstone of catheter ablation in patients with atrial fibrillation (AF). Surround flow and contact force (CF) measurement capabilities might enhance procedure efficacy and safety. We report on the safety and midterm efficacy of a novel ablation catheter for PV isolation in patients with AF. METHODS AND
RESULTS: Two hundred thirty-three consecutive patients (57 ± 11 years, 76% males, 51% with structural heart disease), referred for paroxysmal (157) or persistent (76) AF, underwent PV isolation by a surround flow catheter with CF measurement capability in four centers. Ablation was guided by electroanatomic mapping allowing radiofrequency (RF) energy delivery in the antral region aiming at PV isolation. Mean overall procedure time was 100 ± 42 minutes with a mean fluoroscopy time of 6 ± 5 minutes. Mean ablation time was 31±15 minutes; 99% of the targeted veins were isolated. The mean CF value during ablation was 13 ± 4 g. Intraprocedural early (30 minutes) PV reconnection occurred in 12% PVs, and all PVs were effectively reisolated. One pericardial effusion and five groin hematomas were reported. During a mean follow-up of 12 ± 6 months, 30 (12.9%) (10% paroxysmal AF vs. 18% persistent AF, P = 0.07) patients had an atrial arrhythmias recurrence.
CONCLUSIONS: In this multicenter registry, RF ablation using a new surround flow catheter, with CF sensor, resulted as feasible, achieving a high rate of isolated PVs. Procedural and fluoroscopy times and success rates were comparable with other techniques with a low complication rate.
© 2017 Wiley Periodicals, Inc.

Entities:  

Keywords:  atrial fibrillation; catheter ablation; contact force; midterm outcome; safety; surround flow

Mesh:

Year:  2017        PMID: 28422368     DOI: 10.1111/jce.13227

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  7 in total

1.  Benefit of Contact Force-Guided Catheter Ablation for Treating Premature Ventricular Contractions.

Authors:  Ziming Zhao; Xiaowei Liu; Lianjun Gao; Yutao Xi; Qi Chen; Dong Chang; Xianjie Xiao; Jie Cheng; Yanzong Yang; Yunlong Xia; Xiaomeng Yin
Journal:  Tex Heart Inst J       Date:  2020-02-01

2.  Two years after pulmonary vein isolation guided by ablation index-a multicenter study.

Authors:  Pedro A Sousa; Luís Puga; Luís Adão; João Primo; Ziad Khoueiry; Ana Lebreiro; Paulo Fonseca; Philippe Lagrange; Luís Elvas; Lino Gonçalves
Journal:  J Arrhythm       Date:  2022-03-15

3.  The best of two worlds? Pulmonary vein isolation using a novel radiofrequency ablation catheter incorporating contact force sensing technology and 56-hole porous tip irrigation.

Authors:  Tilman Maurer; Laura Rottner; Hisaki Makimoto; Bruno Reissmann; Christian-H Heeger; Christine Lemes; Thomas Fink; Johannes Riedl; Francesco Santoro; Peter Wohlmuth; Marius Volkmer; Shibu Mathew; Andreas Metzner; Feifan Ouyang; Karl-Heinz Kuck; Christian Sohns
Journal:  Clin Res Cardiol       Date:  2018-05-08       Impact factor: 5.460

4.  Impact of corrected sinus node recovery time in predicting recurrence in patients with paroxysmal atrial fibrillation.

Authors:  Zhi-Song Chen; Hong-Wei Tan; Hao-Ming Song; Wen-Jun Xu; Xue-Bo Liu
Journal:  J Int Med Res       Date:  2021-05       Impact factor: 1.671

Review 5.  Pulsed Field Ablation to Treat Atrial Fibrillation: A Review of the Literature.

Authors:  Antonio Di Monaco; Nicola Vitulano; Federica Troisi; Federico Quadrini; Imma Romanazzi; Valeria Calvi; Massimo Grimaldi
Journal:  J Cardiovasc Dev Dis       Date:  2022-03-24

6.  Safety and efficacy of the ThermoCool SmartTouch SurroundFlow catheter for atrial fibrillation ablation: A meta-analysis.

Authors:  Chao-Feng Chen; Xiao-Fei Gao; Mei-Jun Liu; Chao-Lun Jin; Yi-Zhou Xu
Journal:  Clin Cardiol       Date:  2019-11-19       Impact factor: 2.882

7.  Long-term safety and effectiveness of paroxysmal atrial fibrillation ablation using a porous tip contact force-sensing catheter from the SMART SF trial.

Authors:  Andrea Natale; George Monir; Anshul M Patel; Robert S Fishel; Francis E Marchlinski; M Craig Delaughter; Charles A Athill; Daniel P Melby; Mario D Gonzalez; Ramesh Hariharan; Brett Gidney; Tiffany Tan; Larry A Chinitz
Journal:  J Interv Card Electrophysiol       Date:  2020-05-27       Impact factor: 1.900

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.