Literature DB >> 28415068

Validity and Reliability of a Portable Isometric Mid-Thigh Clean Pull.

Lachlan P James1, Llion A Roberts, G Gregory Haff, Vincent G Kelly, Emma M Beckman.   

Abstract

James, LP, Roberts, LA, Haff, GG, Kelly, VG, and Beckman, EM. Validity and reliability of a portable isometric mid-thigh clean pull. J Strength Cond Res 31(5): 1378-1386, 2017-This study investigated the test-retest reliability and criterion validity of force-time curve variables collected through a portable isometric mid-thigh clean pull (IMTP) device equipped with a single-axial load cell. Fifteen males with ≥6 months of resistance training experience attended two testing sessions. In each session, participants performed an IMTP in 2 separate conditions in a randomized counterbalanced manner. The criterion condition consisted of a closed-chain IMTP configured with a force plate (IMTPf), whereas the experimental test was undertaken using a portable IMTP with data acquired through a single-axial load cell (IMTPl). A very high reliability (coefficient of variation [CV] = 3.10, 90% confidence interval [CI]: 2.4-4.6%; intraclass correlation coefficient [ICC] = 0.96, 90% CI: 0.90-0.98) and acceptable validity (CV = 9.2, 90% CI: 7-14%; ICC = 0.88, 90% CI: 0.71-0.95) were found in the experimental condition for the measure of peak force. However, significant differences were present between the IMTPf and IMTPl (p < 0.0001). Alternate force-time curve variables did not reach acceptable levels of validity or reliability in the experimental condition. The IMTPl is a valid and highly reliable method for assessing peak force. This provides evidence supporting the use of an IMTPl as a cost-effective and portable alternative for those who wish to assess maximal force production in a similar fashion to a traditional IMTP. However, practitioners should be aware that these are slightly different tests.

Entities:  

Mesh:

Year:  2017        PMID: 28415068     DOI: 10.1519/JSC.0000000000001201

Source DB:  PubMed          Journal:  J Strength Cond Res        ISSN: 1064-8011            Impact factor:   3.775


  12 in total

Review 1.  Towards a Determination of the Physiological Characteristics Distinguishing Successful Mixed Martial Arts Athletes: A Systematic Review of Combat Sport Literature.

Authors:  Lachlan P James; G Gregory Haff; Vincent G Kelly; Emma M Beckman
Journal:  Sports Med       Date:  2016-10       Impact factor: 11.136

2.  Force-Time Curve Variable Outcomes Following a Simulated Tennis Match in Junior Players.

Authors:  Joshua Colomar; Francisco Corbi; Ernest Baiget
Journal:  J Sports Sci Med       Date:  2022-06-01       Impact factor: 4.017

3.  Within- and Between-Session Reliability of the Isometric Midthigh Pull in Young Female Athletes.

Authors:  Sylvia Moeskops; Jon L Oliver; Paul J Read; John B Cronin; Gregory D Myer; G Gregory Haff; Rhodri S Lloyd
Journal:  J Strength Cond Res       Date:  2018-07       Impact factor: 3.775

Review 4.  The Validity and Responsiveness of Isometric Lower Body Multi-Joint Tests of Muscular Strength: a Systematic Review.

Authors:  David Drake; Rodney Kennedy; Eric Wallace
Journal:  Sports Med Open       Date:  2017-06-19

5.  Physical Qualities Pertaining to Shorter and Longer Change-of-Direction Speed Test Performance in Men and Women.

Authors:  Robert G Lockie; Brett K Post; J Jay Dawes
Journal:  Sports (Basel)       Date:  2019-02-16

6.  Identifying Reliable and Relatable Force-Time Metrics in Athletes-Considerations for the Isometric Mid-Thigh Pull and Countermovement Jump.

Authors:  Justin J Merrigan; Jason D Stone; W Guy Hornsby; Joshua A Hagen
Journal:  Sports (Basel)       Date:  2020-12-31

7.  Reliability of Low-Cost Near-Infrared Spectroscopy in the Determination of Muscular Oxygen Saturation and Hemoglobin Concentration during Rest, Isometric and Dynamic Strength Activity.

Authors:  Claudia Miranda-Fuentes; Isabel María Guisado-Requena; Pedro Delgado-Floody; Leonidas Arias-Poblete; Alejandro Pérez-Castilla; Daniel Jerez-Mayorga; Luis Javier Chirosa-Rios
Journal:  Int J Environ Res Public Health       Date:  2020-11-27       Impact factor: 3.390

Review 8.  Test-retest reliability of isometric mid-thigh pull maximum strength assessment: a systematic review.

Authors:  Jozo Grgic; Bela Scapec; Pavle Mikulic; Zeljko Pedisic
Journal:  Biol Sport       Date:  2021-06-01       Impact factor: 2.806

9.  Test-Retest Reliability of Functional Electromechanical Dynamometer on Five Sit-to-Stand Measures in Healthy Young Adults.

Authors:  Daniel Jerez-Mayorga; Álvaro Huerta-Ojeda; Luis Javier Chirosa-Ríos; Francisco Guede-Rojas; Iris Paola Guzmán-Guzmán; Leonardo Intelangelo; Claudia Miranda-Fuentes; Pedro Delgado-Floody
Journal:  Int J Environ Res Public Health       Date:  2021-06-25       Impact factor: 3.390

10.  Intra-Trial Reliability and Usefulness of Isometric Mid-Thigh Pull Testing on Portable Force Plates.

Authors:  Ciarán Keogh; D J Collins; Giles Warrington; Tom Comyns
Journal:  J Hum Kinet       Date:  2020-01-31       Impact factor: 2.193

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.