| Literature DB >> 32148571 |
Ciarán Keogh1, D J Collins1, Giles Warrington1, Tom Comyns1.
Abstract
The aim of this study was to assess the intra-trial reliability and usefulness of portable force plates and a customised Isometric Mid-Thigh Pull rig. Twenty males (age: 24.1 ± 2.5 years, body height: 177.7 ± 0.09 cm, body mass: 88.4 ± 17.9 kg) with weightlifting experience ± 12 months attended 1 familiarisation session and 1 testing session where 4 isometric mid-thigh pulls were performed. Maximum force, absolute peak force (PF), relative PF, allometrically scaled PF, and force (150, 200, 250 ms) were deemed reliable (ICC ≥ 0.91 and CV ≤ 9.8%) based on predetermined criteria (ICC ≥ 0.8 and CV ≤ 10%). The impulse and the rate of force development (RFD) were deemed unreliable (ICC ≤ 0.91 and CV ≥ 10 %) at all time points. Maximum force, absolute PF, relative PF to body weight and body mass, rand allometrically scaled PF, had a typical error (TE) lower than the smallest worthwhile change small effect (SWC0.2) and moderate effect (SWC0.5) and were rated as good with regard to usefulness. The TE for force at selected time points (150, 200, 250 ms) was also higher than the SWC0.2, achieving a rating of marginal, but TE was higher than SWC0.5, achieving a rating of good with regard to usefulness. Portable force plates and customised rigs can reliably determine peak force and force output at different time points and for detecting the SWC in maximum and absolute force measures, greater familiarisation may be required to establish reliability of other variables such as the impulse and the RFD.Entities:
Keywords: force time curve; isometric strength; mid-thigh pull; performance testing
Year: 2020 PMID: 32148571 PMCID: PMC7052723 DOI: 10.2478/hukin-2019-0094
Source DB: PubMed Journal: J Hum Kinet ISSN: 1640-5544 Impact factor: 2.193
Figure 1PASCO portable dual force plates in the customised IMTP rig.
Descriptive statistics of all participants for the IMTP and intra-trial reliability. Variables attaining a criterion of an ICC > 0.8 and a CV < 10%
| 95% CI | 95% CI | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Variable | Mean (SD) | ICC | Lower | Upper | CV,% | Lower | Upper | TE | SWC 0.2 | Rating | SWC 0.5 | Rating |
| AlloPF, N/kg0.67 | 13.9 (4.6) | 0.99 | 0.98 | 1 | 2.70 | 2 | 3.9 | 0.49 | 0.9 | Good | 2.3 | Good |
| RPF, N/kg | 21 (6.6) | 0.99 | 0.98 | 1 | 2.5 | 1.9 | 3.7 | 0.72 | 1.3 | Good | 3.3 | Good |
| RPF, N/N | (2.1 0.7) | 0.99 | 0.98 | 1 | 2.5 | 1.9 | 3.7 | 0.07 | 0.1 | Good | 0.35 | Good |
| Absolute PF, N | 1815.9 (561.1) | 0.99 | 0.98 | 1 | 2.5 | 1.9 | 3.7 | 61.61 | 112.2 | Good | 281 | Good |
| Max Force, N | 2681.8 (646.4) | 0.99 | 0.98 | 1 | 1.6 | 1.2 | 2.4 | 60.8 | 129.3 | Good | 323.2 | Good |
| Force at 150 ms | 1885.3 (561.8) | 0.91 | 0.82 | 0.96 | 9.8 | 7.4 | 14.7 | 179.35 | 112.4 | Marginal | 280.9 | Good |
| Force at 200 ms | 2068.20 (589) | 0.95 | 0.92 | 0.98 | 5.6 | 4.4 | 7.7 | 133.85 | 117.8 | Marginal | 294.5 | Good |
| Force at 50 ms | 2162.2 (584.7) | 0.95 | 0.91 | 0.98 | 5.7 | 4.3 | 8.4 | 133.02 | 116.9 | Marginal | 292.4 | Good |
| Force at 300 ms | 2224.1 (590.5) | 0.95 | 0.91 | 0.98 | 7.2 | 5.4 | 10.7 | 134.8 | 118.1 | Marginal | 295.3 | Good |
Abbreviations: AlloPF, allometrically scaled PF; CI, confidence interval; CV, coefficient of variation; ICC, intraclass correlation coefficient; IMTP, isometric midthigh pull; PF, peak force; RPF, relative PF; SWC, smallest worthwhile change; TE, typical error; SD, standard deviation.
Descriptive statistics of all participants for the IMTP and intra-trial reliability. Variables not attaining a criterion of an ICC > 0.8 and a CV < 10%
| 95% CI | 95% CI | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Variable | Mean (SD) | ICC | Lower | Upper | CV,% | Lower | Upper | TE | SWC 0.2 | Rating | SWC 0.5 | Rating |
| Force at 30 ms | 1263 (363) | 0.88 | 0.77 | 0.95 | 11.5 | 8.6 | 17.2 | 132 | 72.6 | Marginal | 181.5 | Good |
| Force at 50 ms | 1364 (388) | 0.85 | 0.73 | 0.93 | 12.8 | 9.6 | 19.2 | 155 | 77.6 | Marginal | 194 | Good |
| Force at 90 ms | 1563 (464) | 0.86 | 0.74 | 0.94 | 13.2 | 9.9 | 19.9 | 183 | 92.8 | Marginal | 232 | Good |
| Force at 100 ms | 1628 (480) | 0.86 | 0.73 | 0.93 | 13.4 | 10.1 | 20.2 | 190 | 96 | Marginal | 240 | Good |
| Force at 300 ms | 2224 (591) | 0.95 | 0.91 | 0.98 | 7.2 | 5.4 | 10.7 | 135 | 118.2 | Marginal | 295.5 | Good |
| Impulse 0-30 ms | 13.9 (10) | 0.63 | 0.4 | 0.81 | 79.9 | 56.3 | 135.7 | 6 | 2 | Marginal | 5 | Good |
| Impulse 0-50 ms | (25.7 15.3) | 0.62 | 0.39 | 0.81 | 66.2 | 47.2 | 110.1 | 9.7 | 3.06 | Marginal | 7.65 | Good |
| Impulse 0-90 ms | (41.5 21.9) | 0.72 | 0.52 | 0.86 | 43.9 | 31.9 | 70.2 | 12.03 | 4.38 | Marginal | 10.95 | Good |
| Impulse 0-100 ms | (51.7 27.3) | 0.73 | 0.54 | 0.87 | 41.9 | 30.5 | 66.8 | 14.67 | 5.46 | Marginal | 13.65 | Good |
| Impulse 0-150 ms | 116.5 (52) | 0.85 | 0.72 | 0.93 | 21.3 | 15.8 | 32.6 | 21.28 | 10.4 | Marginal | 26 | Good |
| Impulse 0-200 ms | 191.9 (73.5) | 0.91 | 0.83 | 0.96 | 16.7 | 12.5 | 25.3 | 22.8 | 14.7 | Marginal | 36.75 | Good |
| Impulse 0-250 ms | 263.4 (93.5) | 0.9 | 0.81 | 0.95 | 17.1 | 12.8 | 26.4 | 31.19 | 18.7 | Marginal | 46.75 | Good |
| Impulse 0-300 ms | (334.7 116.7) | 0.88 | 0.78 | 0.95 | 20.7 | 15.4 | 31.7 | 41.8 | 23.34 | Marginal | 58.35 | Good |
| RFD 0-30 ms | (1710.5 1176.2) | 0.63 | 0.4 | 0.81 | 79.9 | 56.3 | 135.7 | 739.86 | 235.24 | Marginal | 588.1 | Marginal |
| RFD 0-50 ms | (2565.3 1533.2) | 0.62 | 0.39 | 0.81 | 66.2 | 47.2 | 110.1 | 969.84 | 306.64 | Marginal | 766.6 | Marginal |
| RFD 0-90 ms | (5117.7 2708.3) | 0.72 | 0.52 | 0.86 | 43.9 | 31.9 | 70.2 | 1485.36 | 541.66 | Marginal | 1354.15 | Marginal |
| RFD 0-100 ms | (5187.7 2714.8) | 0.74 | 0.55 | 0.87 | 40.7 | 29.6 | 64.6 | 1447.92 | 542.96 | Marginal | 1357.4 | Marginal |
| RFD 0-150 ms | (5176.9 2310.9) | 0.85 | 0.72 | 0.93 | 21.3 | 15.8 | 32.6 | 945.84 | 462.18 | Marginal | 1155.45 | Good |
| RFD 0-200 ms | (4797.4 1837.3) | 0.91 | 0.83 | 0.96 | 16.7 | 12.5 | 25.3 | 560.9 | 367.46 | Marginal | 918.65 | Good |
| RFD 0-250 ms | (4213.9 1496.6) | 0.9 | 0.81 | 0.95 | 17.1 | 12.8 | 26 | 499.04 | 299.32 | Marginal | 748.3 | Good |
| RFD 0-300 ms | (3718.4 1269.9) | 0.88 | 0.78 | 0.95 | 207 | 15.4 | 31.7 | 464.46 | 253.98 | Marginal | 634.95 | Good |
Abbreviations: CI, confidence interval; CV, coefficient of variation; ICC, intraclass correlation coefficient; IMTP, isometric midthigh pull; PF, peak force; RPF, relative PF; RFD, Rate of Force Development; SWC, smallest worthwhile change; TE, typical error; SD, standard deviation
Figure 2Reliability measures of the mean ICCs of the variables attaining an ICC > .8 and CV ≤ 10% in the IMTP. Open circles represent mean ICCs; error bars indicate 95% confidence limits; grey shaded areas represent the zone of acceptable reliability (ICC > .8, CV < 10%). AlloPF indicates allometrically scaled PF; max force, maximum force; Absolute PF, absolute peak force; RPF (N/kg), PF relative to body mass; RPF (N/N), PF relative to body weight. CV, coefficient of variation; ICC, intraclass correlation coefficient; IMTP, isometric midthigh pull. Force at 150, 200, 250 ms, force at selected timepoints from the onset of contraction.