Prognosis associated with redo cardiac resynchronization therapy following complete device and lead extraction due to device-related infection.

Martin Seifert1, Viviane Moeller1, Anita Arya2, Thomas Schau1, Frank Hoelschermann1, Christian Butter1.   

Abstract

Aims: An increase in the number of cardiac resynchronization therapy (CRT) device implantations worldwide has led to a consequent increase in the number of infections associated with the device, making extraction of the CRT device inevitable. Redo CRT implantation after treatment and recovery following device extraction is challenging. This study aimed to evaluate the success rate, complications, and long-term prognosis of redo CRT implantation, including the rates of subclavian, cava, and coronary sinus (CS) vein thrombosis as well as re-infection. Methods and results: Between 2007 and 2014, 1712 lead extractions were performed in 537 patients with device-related infection at Heart Center Brandenburg. Of the 537 patients, 125 (23%) underwent CRT device and lead extraction, including extraction of the left ventricular lead from the coronary sinus. Of these 125, 62 (50%) patients underwent redo CRT implantation (mean age, 68 ± 10 years); 34 patients had coronary artery disease (CAD) while 28 had dilated cardiomyopathy (DCM). The mean left ventricular ejection fraction was 27% ± 7%. The mean QRS duration of the left bundle branch block was 158 (range, 147-162) ms, and 25 patients had atrial fibrillation (AF). All these patients were followed up for a median duration of 29.6 (range, 15-43) months. In 53 of the 62 patients (85%), the CRT system was successfully re-implanted; however, the original CS vein could be used again only in 28 (45%) patients. The all-cause mortality rate was 7.1% after 1 year, and it was significantly higher in patients whose N-terminal pro B-type natriuretic peptide level was  ≥3,000 pg/mL (P < 0.001), those who were aged  ≥64 years (P = 0.028), those who had CAD (P = 0.042) or chronic kidney insufficiency (P = 0.001), those with AF (P = 0.001) and those whose blood cultures were positive for Staphylococcus aureus (P = 0.014).
Conclusion: Redo CRT implantation after device extraction owing to device-related infection has a low success rate and shows a higher rate of re-infection than that observed in patients who undergo CRT implantation for the first time. Further, patients whose blood cultures are positive for S. aureus show a particularly poor outcome.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 28398556     DOI: 10.1093/europace/eux030

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  3 in total

Review 1.  [Leadless endocardial ultrasound based left ventricular stimulation : WISE CRT System: alternative to conventional methods].

Authors:  C Butter; S Fehrendt; V Möller; M Seifert
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2018-11-08

2.  First experience in quadripolar active fixation coronary sinus lead extraction: a case report.

Authors:  Elhosseyn Guella; Michael Brack; Khalid Abozguia; Christopher John Cassidy
Journal:  Eur Heart J Case Rep       Date:  2020-07-22

3.  Prognostic Value of Preoperative Echocardiographic Findings in Patients Undergoing Transvenous Lead Extraction.

Authors:  Dorota Nowosielecka; Wojciech Jacheć; Anna Polewczyk; Łukasz Tułecki; Andrzej Kleinrok; Andrzej Kutarski
Journal:  Int J Environ Res Public Health       Date:  2021-02-14       Impact factor: 3.390