Comparison of gray values of cone-beam computed tomography with hounsfield units of multislice computed tomography: An in vitro study.

Sanjana Patrick1, N Praveen Birur1, Keerthi Gurushanth1, A Shubhasini Raghavan1, Shubha Gurudath1.   

Abstract

PURPOSE: Hounsfield unit (HU) provides a quantitative evaluation of bone density. The assessment of bone density is essential for successful treatment plan. Although, multislice computed tomography (MSCT) is considered as gold standard in evaluating bone density, cone-beam computed tomography (CBCT) is frequently used in dentomaxillofacial imaging due to lower radiation dose, less complex device, and images with satisfactory resolution. AIMS AND
OBJECTIVES: The aim of this study is to determine and compare the gray value and HU value of hypodense and hyperdense structures on CBCT and MSCT, respectively. The study also evaluated and compared the gray values in different field of views within CBCT.
MATERIALS AND METHODS: A total of 20 dry human mandibles were obtained. The gray values and HU values of hypodense structures (extraction socket, inferior alveolar canal, and mental foramen) and hyperdense structures (enamel, cancellous, and cortical bone) were evaluated and compared between CBCT and MSCT images, respectively. The obtained data were statistically analyzed. STATISTICAL ANALYSIS: One-way analyses of variance, ANOVA F-test.
RESULTS: The gray value for hypodense structures in large volume CBCT scans resembled the HU value. The study showed statistically significant difference (P < 0.001) in gray values for all the hyperdense structures in CBCT when compared to HU values of MSCT scans.
CONCLUSION: The gray value for hypodense structures in large volume CBCT scan was more reliable and analogous to HU value in MSCT. The determination of grey values in CBCT may not be as accurate as HU value in CT for hyperdense structures.

Entities:  

Mesh:

Year:  2017        PMID: 28393820     DOI: 10.4103/ijdr.IJDR_415_16

Source DB:  PubMed          Journal:  Indian J Dent Res        ISSN: 0970-9290


  10 in total

1.  Reproducibility of CBCT image analysis: a clinical study on intrapersonal and interpersonal errors in bone structure determination.

Authors:  Sigmar Schnutenhaus; Michael Graf; Isabel Doering; Ralph G Luthardt; Heike Rudolph
Journal:  Oral Radiol       Date:  2018-07-27       Impact factor: 1.852

Review 2.  Correlation between gray values of cone-beam computed tomograms and Hounsfield units of computed tomograms: A systematic review and meta-analysis.

Authors:  Abirami Selvaraj; Ravindra Kumar Jain; Ravleen Nagi; Arthi Balasubramaniam
Journal:  Imaging Sci Dent       Date:  2022-05-13

3.  Cone beam computed tomography - extending its arm to explore new possibilities.

Authors:  Prajakta P Chaudhari; Chetan Bhadage; Ajay Bhoosreddy; Pragati Bramhe; Prutha Rathod; Shreya Dange
Journal:  Pol J Radiol       Date:  2020-07-10

4.  A Comparative Study of Orbital Blow Out Fracture Repair, Using Autogenous Bone Graft and Alloplastic Materials.

Authors:  Asok Kumar Saha; Saikat Samaddar; Amit Kumar; Arup Chakraborty; Biplab Deb
Journal:  Indian J Otolaryngol Head Neck Surg       Date:  2019-08-10

5.  Technical Note: Patient-morphed mesh-type phantoms to support personalized nuclear medicine dosimetry - a proof of concept study.

Authors:  Jason S Lewis; Adam L Kesner; Lukas M Carter; Juan Camilo Ocampo Ramos; Wesley E Bolch
Journal:  Med Phys       Date:  2021-03-09       Impact factor: 4.071

6.  Marginal and internal fit of 3D printed resin graft substitutes mimicking alveolar ridge augmentation: An in vitro pilot study.

Authors:  C C Stoop; K Chatzivasileiou; W E R Berkhout; D Wismeijer
Journal:  PLoS One       Date:  2019-04-15       Impact factor: 3.240

7.  Assessment of the Capability of Bone Density Contrast Dissociation in Cone Beam Computed Tomography Compared to Digital Periapical Radiography by Using a Phantom.

Authors:  Zahra Ghoncheh; Hanieh Kaviani; Hosein Ghadiri Harvani; Daryoush Goodarzipoor; Ahmad Reza Shamshiri; Paria Shams
Journal:  J Dent (Shiraz)       Date:  2019-09

8.  Visual and histological evaluation of the effects of trafermin in a dog oronasal fistula model.

Authors:  Kazuhiro Watanabe; Syun Tahara; Hiroyuki Koyama; Mamu Shimizu; Mifumi Kawabe; Shingo Miyawaki
Journal:  J Vet Med Sci       Date:  2021-11-22       Impact factor: 1.267

9.  X-ray attenuation of bone, soft and adipose tissue in CT from 70 to 140 kV and comparison with 3D printable additive manufacturing materials.

Authors:  Xiangjie Ma; Michael Figl; Ewald Unger; Martin Buschmann; Peter Homolka
Journal:  Sci Rep       Date:  2022-08-26       Impact factor: 4.996

10.  Experiences with image quality and radiation dose of cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) in pediatric extremity trauma.

Authors:  Sebastian Tschauner; Robert Marterer; Eszter Nagy; Georg Singer; Michael Riccabona; Erich Sorantin
Journal:  Skeletal Radiol       Date:  2020-06-14       Impact factor: 2.199