Literature DB >> 28392968

Catadioptric Stereo Tracking for Three Dimensional Shape Measurement of MRI Guided Catheters.

Russell C Jackson1, Taoming Liu1, M Cenk Çavuşoğlu1.   

Abstract

The recent introduction of Magnetic Resonance Imaging (MRI)-actuated steerable catheters lays the ground work for increasing the efficacy of cardiac catheter procedures. The MRI, while capable of imaging the catheter for tracking and control, does not fulfill all of the needs required to identify and develop a complete catheter model. Specifially, the frequency response of the catheter must be identified to ensure stable control of the catheter system. This requires a higher frequency imaging than the MRI can achieve. This work uses a catadioptric stereo camera system consisting of a mirror and a single camera in order to track a MRI actuated catheter inside a MRI machine. The catadioptric system works in parallel to the MRI and is capable of recording the catheter at 60 fps for post processing. The accuracy of the catadioptric system is verified in imaging conditions that would be found inside the MRI. The stereo camera is then used to track a catheter as it is actuated inside the MRI.

Entities:  

Year:  2016        PMID: 28392968      PMCID: PMC5382962          DOI: 10.1109/ICRA.2016.7487641

Source DB:  PubMed          Journal:  IEEE Int Conf Robot Autom        ISSN: 2154-8080


  10 in total

1.  Magnetically-Assisted Remote Controlled Microcatheter Tip Deflection under Magnetic Resonance Imaging.

Authors:  Steven W Hetts; Maythem Saeed; Alastair Martin; Prasheel Lillaney; Aaron Losey; Erin Jeannie Yee; Ryan Sincic; Loi Do; Lee Evans; Vincent Malba; Anthony F Bernhardt; Mark W Wilson; Anand Patel; Ronald L Arenson; Curtis Caton; Daniel L Cooke
Journal:  J Vis Exp       Date:  2013-04-04       Impact factor: 1.355

Review 2.  2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design.

Authors:  Hugh Calkins; Karl Heinz Kuck; Riccardo Cappato; Josep Brugada; A John Camm; Shih-Ann Chen; Harry J G Crijns; Ralph J Damiano; D Wyn Davies; John DiMarco; James Edgerton; Kenneth Ellenbogen; Michael D Ezekowitz; David E Haines; Michel Haissaguerre; Gerhard Hindricks; Yoshito Iesaka; Warren Jackman; Jose Jalife; Pierre Jais; Jonathan Kalman; David Keane; Young-Hoon Kim; Paulus Kirchhof; George Klein; Hans Kottkamp; Koichiro Kumagai; Bruce D Lindsay; Moussa Mansour; Francis E Marchlinski; Patrick M McCarthy; J Lluis Mont; Fred Morady; Koonlawee Nademanee; Hiroshi Nakagawa; Andrea Natale; Stanley Nattel; Douglas L Packer; Carlo Pappone; Eric Prystowsky; Antonio Raviele; Vivek Reddy; Jeremy N Ruskin; Richard J Shemin; Hsuan-Ming Tsao; David Wilber
Journal:  J Interv Card Electrophysiol       Date:  2012-03       Impact factor: 1.900

3.  Comparing deflection measurements of a magnetically steerable catheter using optical imaging and MRI.

Authors:  Prasheel Lillaney; Curtis Caton; Alastair J Martin; Aaron D Losey; Leland Evans; Maythem Saeed; Daniel L Cooke; Mark W Wilson; Steven W Hetts
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

4.  Three Dimensional Modeling of an MRI Actuated Steerable Catheter System.

Authors:  Taoming Liu; M Cenk Cavuşoğlu
Journal:  IEEE Int Conf Robot Autom       Date:  2014

5.  Task-Space Motion Planning of MRI-Actuated Catheters for Catheter Ablation of Atrial Fibrillation.

Authors:  Tipakorn Greigarn; M Cenk Cavuşoğlu
Journal:  Rep U S       Date:  2014-09

Review 6.  Magnetic Resonance Sequences and Rapid Acquisition for MR-Guided Interventions.

Authors:  Adrienne E Campbell-Washburn; Anthony Z Faranesh; Robert J Lederman; Michael S Hansen
Journal:  Magn Reson Imaging Clin N Am       Date:  2015-08-12       Impact factor: 2.266

7.  Modeling and Validation of the Three-Dimensional Deflection of an MRI-Compatible Magnetically Actuated Steerable Catheter.

Authors:  Taoming Liu; Nate Lombard Poirot; Dominique Franson; Nicole Seiberlich; Mark A Griswold; M Cenk Cavusoglu
Journal:  IEEE Trans Biomed Eng       Date:  2015-12-22       Impact factor: 4.538

8.  Pseudo-Rigid-Body Model and Kinematic Analysis of MRI-Actuated Catheters.

Authors:  Tipakorn Greigarn; M Cenk Çavuşoğlu
Journal:  IEEE Int Conf Robot Autom       Date:  2015-05

9.  Automatic Initialization and Dynamic Tracking of Surgical Suture Threads.

Authors:  Russell C Jackson; Rick Yuan; Der-Lin Chow; Wyatt Newman; M Cenk Çavuşoğlu
Journal:  IEEE Int Conf Robot Autom       Date:  2015-05-26

Review 10.  Interventional cardiovascular magnetic resonance: still tantalizing.

Authors:  Kanishka Ratnayaka; Anthony Z Faranesh; Michael A Guttman; Ozgur Kocaturk; Christina E Saikus; Robert J Lederman
Journal:  J Cardiovasc Magn Reson       Date:  2008-12-29       Impact factor: 5.364

  10 in total
  3 in total

1.  Iterative Jacobian-Based Inverse Kinematics and Open-Loop Control of an MRI-Guided Magnetically Actuated Steerable Catheter System.

Authors:  Taoming Liu; Russell Jackson; Dominique Franson; Nate Lombard Poirot; Reinhardt Kam Criss; Nicole Seiberlich; Mark A Griswold; M Cenk Çavuşoğlu
Journal:  IEEE ASME Trans Mechatron       Date:  2017-05-16       Impact factor: 5.303

2.  State Estimation for MRI-Actuated Catheters via Catadioptric Stereo Camera.

Authors:  Tipakorn Greigarn; Russell Jackson; M Cenk Çavuşoğlu
Journal:  Rep U S       Date:  2019-01-07

3.  Experimental Validation of the Pseudo-Rigid-Body Model of the MRI-Actuated Catheter.

Authors:  Tipakorn Greigarn; Russell Jackson; Taoming Liu; M Cenk Çavuşoğlu
Journal:  IEEE Int Conf Robot Autom       Date:  2017-07-24
  3 in total