Literature DB >> 28385939

Low-intensity pulsed ultrasound does not influence bone healing by distraction osteogenesis: a multicentre double-blind randomised control trial.

A H R W Simpson1, G Keenan1, S Nayagam2, R M Atkins3, D Marsh4, N D Clement1.   

Abstract

AIMS: The aim of this double-blind prospective randomised controlled trial was to assess whether low intensity pulsed ultrasound (LIPUS) accelerated or enhanced the rate of bone healing in adult patients undergoing distraction osteogenesis. PATIENTS AND METHODS: A total of 62 adult patients undergoing limb lengthening or bone transport by distraction osteogenesis were randomised to treatment with either an active (n = 32) or a placebo (n = 30) ultrasound device. A standardised corticotomy was performed in the proximal tibial metaphysis and a circular Ilizarov frame was used in all patients. The rate of distraction was also standardised. The primary outcome measure was the time to removal of the frame after adjusting for the length of distraction in days/cm for both the per protocol (PP) and the intention-to-treat (ITT) groups. The assessor was blinded to the form of treatment. A secondary outcome was to identify covariates affecting the time to removal of the frame.
RESULTS: There was no difference in the time to removal of the frame between the PP (difference in favour of the control group was 10.1 days/cm, 95% confidence interval (CI) -3.2 to 23.4, p = 0.054) or ITT (difference 5.0 days/cm, 95% CI -8.2 to 18.21, p = 0.226) groups. The smoking status was the only covariate which increased the time to removal of the frame (hazard ratio 0.47, 95% CI 0.22 to 0.97, p = 0.042).
CONCLUSION: LIPUS does not influence the rate of bone healing in patients who undergo distraction osteogenesis. Smoking may influence bone healing. Cite this article: Bone Joint J 2017;99-B:494-502. ©2017 The British Editorial Society of Bone & Joint Surgery.

Entities:  

Keywords:  Exogen; Fracture; Healing; Pulsed; Ultrasound

Mesh:

Year:  2017        PMID: 28385939     DOI: 10.1302/0301-620X.99B4.BJJ-2016-0559.R1

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  4 in total

1.  Effect of low-intensity pulsed ultrasound on distraction osteogenesis: a systematic review and meta-analysis of randomized controlled trials.

Authors:  Shenghan Lou; Houchen Lv; Zhirui Li; Peifu Tang; Yansong Wang
Journal:  J Orthop Surg Res       Date:  2018-08-17       Impact factor: 2.359

2.  Application of Ilizarov transverse tibial bone transport and microcirculation reconstruction in the treatment of chronic ischemic diseases in lower limbs.

Authors:  Qiang Zuo; Feng Gao; Huanghe Song; Jinchun Zhou
Journal:  Exp Ther Med       Date:  2018-06-18       Impact factor: 2.447

3.  What is the role of ultrasound in fracture management?: Diagnosis and therapeutic potential for fractures, delayed unions, and fracture-related infection.

Authors:  J A Nicholson; S T J Tsang; T J MacGillivray; F Perks; A H R W Simpson
Journal:  Bone Joint Res       Date:  2019-08-02       Impact factor: 5.853

Review 4.  Low-Intensity Pulsed Ultrasound Stimulation for Bone Fractures Healing: A Review.

Authors:  Poornima Palanisamy; Monzurul Alam; Shuai Li; Simon K H Chow; Yong-Ping Zheng
Journal:  J Ultrasound Med       Date:  2021-05-05       Impact factor: 2.754

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.