The effect of noise and lipid signals on determination of Gaussian and non-Gaussian diffusion parameters in skeletal muscle.

Donnie Cameron1,2, Mustapha Bouhrara1, David A Reiter1, Kenneth W Fishbein1, Seongjin Choi1, Christopher M Bergeron1, Luigi Ferrucci1, Richard G Spencer1.   

Abstract

This work characterizes the effect of lipid and noise signals on muscle diffusion parameter estimation in several conventional and non-Gaussian models, the ultimate objectives being to characterize popular fat suppression approaches for human muscle diffusion studies, to provide simulations to inform experimental work and to report normative non-Gaussian parameter values. The models investigated in this work were the Gaussian monoexponential and intravoxel incoherent motion (IVIM) models, and the non-Gaussian kurtosis and stretched exponential models. These were evaluated via simulations, and in vitro and in vivo experiments. Simulations were performed using literature input values, modeling fat contamination as an additive baseline to data, whereas phantom studies used a phantom containing aliphatic and olefinic fats and muscle-like gel. Human imaging was performed in the hamstring muscles of 10 volunteers. Diffusion-weighted imaging was applied with spectral attenuated inversion recovery (SPAIR), slice-select gradient reversal and water-specific excitation fat suppression, alone and in combination. Measurement bias (accuracy) and dispersion (precision) were evaluated, together with intra- and inter-scan repeatability. Simulations indicated that noise in magnitude images resulted in <6% bias in diffusion coefficients and non-Gaussian parameters (α, K), whereas baseline fitting minimized fat bias for all models, except IVIM. In vivo, popular SPAIR fat suppression proved inadequate for accurate parameter estimation, producing non-physiological parameter estimates without baseline fitting and large biases when it was used. Combining all three fat suppression techniques and fitting data with a baseline offset gave the best results of all the methods studied for both Gaussian diffusion and, overall, for non-Gaussian diffusion. It produced consistent parameter estimates for all models, except IVIM, and highlighted non-Gaussian behavior perpendicular to muscle fibers (α ~ 0.95, K ~ 3.1). These results show that effective fat suppression is crucial for accurate measurement of non-Gaussian diffusion parameters, and will be an essential component of quantitative studies of human muscle quality. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.

Entities:  

Keywords:  diffusion-weighted imaging; fat suppression; muscle; non-Gaussian diffusion; parameter estimation

Mesh:

Year:  2017        PMID: 28383778      PMCID: PMC5876728          DOI: 10.1002/nbm.3718

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  37 in total

1.  Characterization of continuously distributed cortical water diffusion rates with a stretched-exponential model.

Authors:  Kevin M Bennett; Kathleen M Schmainda; Raoqiong Tong Bennett; Daniel B Rowe; Hanbing Lu; James S Hyde
Journal:  Magn Reson Med       Date:  2003-10       Impact factor: 4.668

2.  An in vivo verification of the intravoxel incoherent motion effect in diffusion-weighted imaging of the abdomen.

Authors:  Andreas Lemke; Frederik B Laun; Dirk Simon; Bram Stieltjes; Lothar R Schad
Journal:  Magn Reson Med       Date:  2010-07-27       Impact factor: 4.668

3.  Usefulness of diffusion-weighted MRI with echo-planar technique in the evaluation of cellularity in gliomas.

Authors:  T Sugahara; Y Korogi; M Kochi; I Ikushima; Y Shigematu; T Hirai; T Okuda; L Liang; Y Ge; Y Komohara; Y Ushio; M Takahashi
Journal:  J Magn Reson Imaging       Date:  1999-01       Impact factor: 4.813

Review 4.  Techniques and applications of skeletal muscle diffusion tensor imaging: A review.

Authors:  Jos Oudeman; Aart J Nederveen; Gustav J Strijkers; Mario Maas; Peter R Luijten; Martijn Froeling
Journal:  J Magn Reson Imaging       Date:  2015-07-29       Impact factor: 4.813

5.  Simultaneous spatial and spectral selective excitation.

Authors:  C H Meyer; J M Pauly; A Macovski; D G Nishimura
Journal:  Magn Reson Med       Date:  1990-08       Impact factor: 4.668

Review 6.  Fiber types in mammalian skeletal muscles.

Authors:  Stefano Schiaffino; Carlo Reggiani
Journal:  Physiol Rev       Date:  2011-10       Impact factor: 37.312

7.  Gradient reversal technique and its applications to chemical-shift-related NMR imaging.

Authors:  H W Park; D J Kim; Z H Cho
Journal:  Magn Reson Med       Date:  1987-06       Impact factor: 4.668

8.  Diffusional kurtosis imaging: the quantification of non-gaussian water diffusion by means of magnetic resonance imaging.

Authors:  Jens H Jensen; Joseph A Helpern; Anita Ramani; Hanzhang Lu; Kyle Kaczynski
Journal:  Magn Reson Med       Date:  2005-06       Impact factor: 4.668

9.  Removal of olefinic fat chemical shift artifact in diffusion MRI.

Authors:  D Hernando; D C Karampinos; K F King; J P Haldar; S Majumdar; J G Georgiadis; Z-P Liang
Journal:  Magn Reson Med       Date:  2010-12-08       Impact factor: 4.668

10.  Practical signal-to-noise ratio quantification for sensitivity encoding: application to coronary MR angiography.

Authors:  Jing Yu; Harsh Agarwal; Matthias Stuber; Michael Schär
Journal:  J Magn Reson Imaging       Date:  2011-06       Impact factor: 4.813

View more
  5 in total

1.  A simple and fast adaptive nonlocal multispectral filtering algorithm for efficient noise reduction in magnetic resonance imaging.

Authors:  Mustapha Bouhrara; Michael C Maring; Richard G Spencer
Journal:  Magn Reson Imaging       Date:  2018-08-24       Impact factor: 2.546

2.  Diffusion-weighted MRI with intravoxel incoherent motion modeling for assessment of muscle perfusion in the thigh during post-exercise hyperemia in younger and older adults.

Authors:  Fatemeh Adelnia; Michelle Shardell; Christopher M Bergeron; Kenneth W Fishbein; Richard G Spencer; Luigi Ferrucci; David A Reiter
Journal:  NMR Biomed       Date:  2019-03-12       Impact factor: 4.044

Review 3.  Intravoxel Incoherent Motion Magnetic Resonance Imaging in Skeletal Muscle: Review and Future Directions.

Authors:  Erin K Englund; David A Reiter; Bahar Shahidi; Eric E Sigmund
Journal:  J Magn Reson Imaging       Date:  2021-08-14       Impact factor: 5.119

4.  Use of the NESMA Filter to Improve Myelin Water Fraction Mapping with Brain MRI.

Authors:  Mustapha Bouhrara; David A Reiter; Michael C Maring; Jean-Marie Bonny; Richard G Spencer
Journal:  J Neuroimaging       Date:  2018-07-12       Impact factor: 2.486

5.  Parsimonious modeling of skeletal muscle perfusion: Connecting the stretched exponential and fractional Fickian diffusion.

Authors:  David A Reiter; Fatemeh Adelnia; Donnie Cameron; Richard G Spencer; Luigi Ferrucci
Journal:  Magn Reson Med       Date:  2021-03-16       Impact factor: 3.737

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.