PURPOSE: To assess the performance of various least squares and Bayesian modeling approaches to parameter estimation in intravoxel incoherent motion (IVIM) modeling of diffusion-weighted MRI data.
METHODS: Simulated tissue models of different type (breast/liver) and morphology (discrete/continuous) were used to generate noisy data according to the IVIM model at several signal-to-noise ratios. IVIM parameter maps were generated using six different approaches, including full nonlinear least squares (LSQ), segmented least squares (SEG), Bayesian modeling with a Gaussian shrinkage prior (BSP) and Bayesian modeling with a spatial homogeneity prior (FBM), plus two modified approaches. Estimators were compared by calculating the median absolute percentage error and deviation, and median percentage bias.
RESULTS: The Bayesian modeling approaches consistently outperformed the least squares approaches, with lower relative error and deviation, and provided cleaner parameter maps with reduced erroneous heterogeneity. However, a weakness of the Bayesian approaches was exposed, whereby certain tissue features disappeared completely in regions of high parameter uncertainty. Lower error and deviation were generally afforded by FBM compared with BSP, at the cost of higher bias.
CONCLUSIONS: Bayesian modeling is capable of producing more visually pleasing IVIM parameter maps than least squares approaches, but their potential to mask certain tissue features demands caution during implementation. Magn Reson Med 78:2373-2387, 2017.
© 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  Bayesian analysis; diffusion MRI; estimation techniques; intravoxel incoherent motion; least squares

Mesh:

Year:  2017        PMID: 28370232     DOI: 10.1002/mrm.26598

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  17 in total

1.  Comparison of methods for estimation of the intravoxel incoherent motion (IVIM) diffusion coefficient (D) and perfusion fraction (f).

Authors:  Oscar Jalnefjord; Mats Andersson; Mikael Montelius; Göran Starck; Anna-Karin Elf; Viktor Johanson; Johanna Svensson; Maria Ljungberg
Journal:  MAGMA       Date:  2018-08-16       Impact factor: 2.310

2.  Relative enhanced diffusivity: noise sensitivity, protocol optimization, and the relation to intravoxel incoherent motion.

Authors:  Peter T While; Jose R Teruel; Igor Vidić; Tone F Bathen; Pål Erik Goa
Journal:  MAGMA       Date:  2017-11-06       Impact factor: 2.310

3.  Intravoxel incoherent motion diffusion-weighted imaging in the characterization of Alzheimer's disease.

Authors:  Nengzhi Xia; Yanxuan Li; Yingnan Xue; Weikang Li; Zhenhua Zhang; Caiyun Wen; Jiance Li; Qiong Ye
Journal:  Brain Imaging Behav       Date:  2021-09-04       Impact factor: 3.978

4.  Precision of region of interest-based tri-exponential intravoxel incoherent motion quantification and the role of the Intervoxel spatial distribution of flow velocities.

Authors:  Gregory Simchick; Diego Hernando
Journal:  Magn Reson Med       Date:  2022-08-15       Impact factor: 3.737

5.  b value and first-order motion moment optimized data acquisition for repeatable quantitative intravoxel incoherent motion DWI.

Authors:  Gregory Simchick; Ruiqi Geng; Yuxin Zhang; Diego Hernando
Journal:  Magn Reson Med       Date:  2022-01-28       Impact factor: 3.737

Review 6.  Non-Invasive Evaluation of Cerebral Microvasculature Using Pre-Clinical MRI: Principles, Advantages and Limitations.

Authors:  Bram Callewaert; Elizabeth A V Jones; Uwe Himmelreich; Willy Gsell
Journal:  Diagnostics (Basel)       Date:  2021-05-21

Review 7.  Perfusion-driven Intravoxel Incoherent Motion (IVIM) MRI in Oncology: Applications, Challenges, and Future Trends.

Authors:  Mami Iima
Journal:  Magn Reson Med Sci       Date:  2020-06-15       Impact factor: 2.471

8.  Bayesian intravoxel incoherent motion parameter mapping in the human heart.

Authors:  Georg R Spinner; Constantin von Deuster; Kerem C Tezcan; Christian T Stoeck; Sebastian Kozerke
Journal:  J Cardiovasc Magn Reson       Date:  2017-11-06       Impact factor: 5.364

9.  Comparison of six fit algorithms for the intra-voxel incoherent motion model of diffusion-weighted magnetic resonance imaging data of pancreatic cancer patients.

Authors:  Oliver J Gurney-Champion; Remy Klaassen; Martijn Froeling; Sebastiano Barbieri; Jaap Stoker; Marc R W Engelbrecht; Johanna W Wilmink; Marc G Besselink; Arjan Bel; Hanneke W M van Laarhoven; Aart J Nederveen
Journal:  PLoS One       Date:  2018-04-04       Impact factor: 3.240

10.  Diffusion kurtosis imaging with free water elimination: A bayesian estimation approach.

Authors:  Quinten Collier; Jelle Veraart; Ben Jeurissen; Floris Vanhevel; Pim Pullens; Paul M Parizel; Arnold J den Dekker; Jan Sijbers
Journal:  Magn Reson Med       Date:  2018-02-02       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.