Literature DB >> 28363894

Early performance-based and patient-reported outcomes of a contemporary taper fit bone-conserving short stem femoral component in total hip arthroplasty.

F Hossain1, S Konan1, A Volpin1, F S Haddad2.   

Abstract

AIMS: The aim of this study was to compare early functional and health related quality of life outcomes (HRQoL) in patients who have undergone total hip arthroplasty (THA) using a bone conserving short stem femoral component and those in whom a conventional length uncemented component was used. Outcome was assessed using a validated performance based outcome instrument as well as patient reported outcome measures (PROMs). PATIENTS AND METHODS: We prospectively analysed 33 patients whose THA involved a contemporary proximally porous coated tapered short stem femoral component and 53 patients with a standard conventional femoral component, at a minimum follow-up of two years. The mean follow-up was 31.4 months (24 to 39). Patients with poor proximal femoral bone quality were excluded. The mean age of the patients was 66.6 years (59 to 77) and the mean body mass index was 30.2 kg/m2 (24.1 to 41.0). Outcome was assessed using the Oxford Hip Score (OHS) and the University College Hospital (UCH) hip score which is a validated performance based instrument. HRQoL was assessed using the EuroQol 5D (EQ-5D).
RESULTS: There were no major peri-operative complications. There was no difference in the mean post-operative OHS, EQ-5D or function subscale of the UCH hip scores between the two groups. The mean pre-operative OHS and EQ-5D scores improved significantly (all p < 0.001). The mean functional component of the UCH hip score at final follow-up was 42.5 and 40.6 in the short stem and conventional stem groups, respectively. There was no statistically significant difference between the groups (p = 0.42). A total of seven patients (21.2%) in the short stem group and nine (16.98%) in the conventional group achieved a ceiling effect using the OHS; none did using the function subscale of the UCH hip score.
CONCLUSION: The proximally porous coated tapered short stem femoral component achieves comparable short-term functional outcomes when compared with a conventional longer stem uncemented femoral component when THA is undertaken in patients with good bone quality. Cite this article: Bone Joint J 2017;99-B(4 Supple B):49-55. ©2017 Hossain et al.

Entities:  

Keywords:  Functional outcomes; Short stem hip arthroplasty; University College Hospital hip score

Mesh:

Year:  2017        PMID: 28363894     DOI: 10.1302/0301-620X.99B4.BJJ-2016-1291.R1

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  7 in total

1.  Outcome of short versus conventional stem for total hip arthroplasty in the femur with a high cortical index: a five year follow-up prospective multicentre comparative study.

Authors:  Francesco Pogliacomi; Paolo Schiavi; Guido Grappiolo; Francesco Ceccarelli; Enrico Vaienti
Journal:  Int Orthop       Date:  2019-04-24       Impact factor: 3.075

2.  Early clinical and radiological outcomes for the Taperloc Complete Microplasty stem.

Authors:  Xavier Gallart; Jenaro A Fernández-Valencia; Gina Ríos; Guillem Bori; Josep Riba; Ernesto Muñoz-Mahamud; Andres Combalía
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-11-08

3.  Clinical evaluation of the cemented Exeter Short 125 mm stem at a minimum of 3 years: A prospective cohort study.

Authors:  Rebecca Martin; Natalie Clark; Juliet James; Paul Baker
Journal:  J Orthop       Date:  2022-02-07

4.  Short versus conventional stem in cementless total hip arthroplasty : An evidence-based approach with registry data of mid-term survival.

Authors:  Arnd Steinbrück; Alexander W Grimberg; Johanna Elliott; Oliver Melsheimer; Volkmar Jansson
Journal:  Orthopade       Date:  2021-03-05       Impact factor: 1.087

5.  The loading patterns of a short femoral stem in total hip arthroplasty: gait analysis at increasing walking speeds and inclines.

Authors:  Anatole V Wiik; Mads Brevadt; Hardeep Johal; Kartik Logishetty; Oliver Boughton; Adeel Aqil; Justin P Cobb
Journal:  J Orthop Traumatol       Date:  2018-08-17

6.  Malalignment and distal contact of short tapered stems could be associated with postoperative thigh pain in primary total hip arthroplasty.

Authors:  Zhijie Chen; Bin Li; Kaizhe Chen; Jianmin Feng; Yi Wang; Zhihong Liu; Chuan He
Journal:  J Orthop Surg Res       Date:  2021-01-19       Impact factor: 2.359

7.  Biomechanics of a cemented short stem: a comparative in vitro study regarding primary stability and maximum fracture load.

Authors:  Tobias Freitag; Karl Philipp Kutzner; Ralf Bieger; Heiko Reichel; Anita Ignatius; Lutz Dürselen
Journal:  Arch Orthop Trauma Surg       Date:  2021-03-23       Impact factor: 3.067

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.