Literature DB >> 28355548

Deconvolution of Camera Instrument Response Functions.

John H Lewis1, Ryan M Jamiolkowski2, Michael S Woody2, E Michael Ostap2, Yale E Goldman3.   

Abstract

Temporal sequences of fluorescence intensities in single-molecule experiments are often obtained from stacks of camera images. The dwell times of different macromolecular structural or functional states, correlated with characteristic fluorescence intensities, are extracted from the images and combined into dwell time distributions that are fitted by kinetic functions to extract corresponding rate constants. The frame rate of the camera limits the time resolution of the experiment and thus the fastest rate processes that can be reliably detected and quantified. However, including the influence of discrete sampling (framing) on the detected time series in the fitted model enables rate processes near to the frame rate to be reliably estimated. This influence, similar to the instrument response function in other types of instruments, such as pulsed emission decay fluorometers, is easily incorporated into the fitted model. The same concept applies to any temporal data that is low-pass filtered or decimated to improve signal to noise ratio.
Copyright © 2017 Biophysical Society. Published by Elsevier Inc. All rights reserved.

Mesh:

Substances:

Year:  2017        PMID: 28355548      PMCID: PMC5376110          DOI: 10.1016/j.bpj.2017.02.014

Source DB:  PubMed          Journal:  Biophys J        ISSN: 0006-3495            Impact factor:   4.033


  10 in total

1.  Analysis of single-molecule FRET trajectories using hidden Markov modeling.

Authors:  Sean A McKinney; Chirlmin Joo; Taekjip Ha
Journal:  Biophys J       Date:  2006-06-09       Impact factor: 4.033

2.  Assembly dynamics of microtubules at molecular resolution.

Authors:  Jacob W J Kerssemakers; E Laura Munteanu; Liedewij Laan; Tim L Noetzel; Marcel E Janson; Marileen Dogterom
Journal:  Nature       Date:  2006-06-25       Impact factor: 49.962

Review 3.  A practical guide to single-molecule FRET.

Authors:  Rahul Roy; Sungchul Hohng; Taekjip Ha
Journal:  Nat Methods       Date:  2008-06       Impact factor: 28.547

4.  Effect of time discretization of the imaging process on the accuracy of trajectory estimation in fluorescence microscopy.

Authors:  Yau Wong; Jerry Chao; Zhiping Lin; Raimund J Ober
Journal:  Opt Express       Date:  2014-08-25       Impact factor: 3.894

5.  Single-molecule stepping and structural dynamics of myosin X.

Authors:  Yujie Sun; Osamu Sato; Felix Ruhnow; Mark E Arsenault; Mitsuo Ikebe; Yale E Goldman
Journal:  Nat Struct Mol Biol       Date:  2010-04-04       Impact factor: 15.369

6.  Maximum entropy method of data analysis in time-resolved spectroscopy.

Authors:  J C Brochon
Journal:  Methods Enzymol       Date:  1994       Impact factor: 1.600

7.  Single-molecule fluorescence measurements of ribosomal translocation dynamics.

Authors:  Chunlai Chen; Benjamin Stevens; Jaskarin Kaur; Diana Cabral; Hanqing Liu; Yuhong Wang; Haibo Zhang; Gabriel Rosenblum; Zeev Smilansky; Yale E Goldman; Barry S Cooperman
Journal:  Mol Cell       Date:  2011-05-06       Impact factor: 17.970

8.  Myosin V walks hand-over-hand: single fluorophore imaging with 1.5-nm localization.

Authors:  Ahmet Yildiz; Joseph N Forkey; Sean A McKinney; Taekjip Ha; Yale E Goldman; Paul R Selvin
Journal:  Science       Date:  2003-06-05       Impact factor: 47.728

9.  MEMLET: An Easy-to-Use Tool for Data Fitting and Model Comparison Using Maximum-Likelihood Estimation.

Authors:  Michael S Woody; John H Lewis; Michael J Greenberg; Yale E Goldman; E Michael Ostap
Journal:  Biophys J       Date:  2016-07-26       Impact factor: 4.033

Review 10.  Visualizing recombination intermediates with single-stranded DNA curtains.

Authors:  Zhi Qi; Eric C Greene
Journal:  Methods       Date:  2016-03-30       Impact factor: 3.608

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.