Literature DB >> 28352046

Evaluation of SYBR green I based visual loop-mediated isothermal amplification (LAMP) assay for genus and species-specific diagnosis of malaria in P. vivax and P. falciparum endemic regions.

Ruchi Singh1, Dhirendra Pratap Singh2, Deepali Savargaonkar2, Om P Singh2, Rajendra M Bhatt3, Neena Valecha2.   

Abstract

BACKGROUND &
OBJECTIVES: Loop-mediated isothermal amplification (LAMP) is an emerging nucleic acid based diag- nostic approach that is easily adaptable to the field settings with limited technical resources. This study was aimed to evaluate the LAMP assay for the detection and identification of Plasmodium falciparum and P. vivax infection in malaria suspected cases using genus and species-specific assay.
METHODS: The 18S rRNA-based LAMP assay was evaluated for diagnosis of genus Plasmodium, and species- specific diagnosis of P. falciparum and P. vivax, infection employing 317 malaria suspected cases, and the results were compared with those obtained by 18S nested PCR (n-PCR). All the samples were confirmed by microscopy for the presence of Plasmodium parasite.
RESULTS: The n-PCR was positive in all Plasmodium-infected cases (n=257; P. falciparum=133; P. vivax=124) and negative in microscopy negative cases (n=58) except for two cases which were positive for P. vivax, giving a sen- sitivity of 100% (95% CI: 97.04-100%) and a specificity of 100% (95% CI: 88.45-99.5%). Genus-specific LAMP assay missed 11 (3.2%) microscopy and n-PCR confirmed vivax malaria cases. Considering PCR results as a refer- ence, LAMP was 100% sensitive and specific for P. falciparum, whereas it exhibited 95.16% sensitivity and 96.7% specificity for P. vivax. The n-PCR assay detected 10 mixed infection cases while species-specific LAMP detected five mixed infection cases of P. vivax and P. falciparum, which were not detected by microscopy. INTERPRETATION &
CONCLUSION: Genus-specific LAMP assay displayed low sensitivity. Falciparum specific LAMP assay displayed high sensitivity whereas vivax specific LAMP assay displayed low sensitivity. Failed detection of vivax cases otherwise confirmed by the n-PCR assay indicates exploitation of new targets and improved detection methods to attain 100% results for P. vivax detection.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28352046

Source DB:  PubMed          Journal:  J Vector Borne Dis        ISSN: 0972-9062            Impact factor:   1.688


  14 in total

1.  Development of Visually Improved Loop Mediated Isothermal Amplification for the Diagnosis of Plasmodium vivax Malaria in a Tertiary Hospital in Chandigarh, North India.

Authors:  Hargobinder Kaur; Rakesh Sehgal; Devendra Bansal; Ali A Sultan; Ashish Bhalla; Sunit C Singhi
Journal:  Am J Trop Med Hyg       Date:  2018-03-15       Impact factor: 2.345

2.  Evaluation of WarmStart Colorimetric Loop-Mediated Isothermal Amplification Assay for Diagnosis of Malaria.

Authors:  Meng Yee Lai; Choo Huck Ooi; Joel Judson Jaimin; Yee Ling Lau
Journal:  Am J Trop Med Hyg       Date:  2020-06       Impact factor: 2.345

3.  Diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for screening patients with imported malaria in a non-endemic setting.

Authors:  Camille Ponce; Flora Kaczorowski; Thomas Perpoint; Patrick Miailhes; Alain Sigal; Etienne Javouhey; Yves Gillet; Laurent Jacquin; Marion Douplat; Karim Tazarourte; Véronique Potinet; Bruno Simon; Adeline Lavoignat; Guillaume Bonnot; Fatimata Sow; Anne-Lise Bienvenu; Stéphane Picot
Journal:  Parasite       Date:  2017-12-18       Impact factor: 3.000

4.  Dynamics of Plasmodium vivax sporogony in wild Anopheles stephensi in a malaria-endemic region of Western India.

Authors:  Praveen Balabaskaran Nina; Ajeet Kumar Mohanty; Shuvankar Ballav; Smita Vernekar; Sushma Bhinge; Maria D'souza; Jayashree Walke; Suresh Kumar Manoharan; Anjali Mascarenhas; Edwin Gomes; Laura Chery; Neena Valecha; Ashwani Kumar; Pradipsinh K Rathod
Journal:  Malar J       Date:  2017-07-11       Impact factor: 2.979

Review 5.  Converging Human and Malaria Vector Diagnostics with Data Management towards an Integrated Holistic One Health Approach.

Authors:  Konstantinos Mitsakakis; Sebastian Hin; Pie Müller; Nadja Wipf; Edward Thomsen; Michael Coleman; Roland Zengerle; John Vontas; Konstantinos Mavridis
Journal:  Int J Environ Res Public Health       Date:  2018-02-03       Impact factor: 3.390

6.  Loop-mediated isothermal amplification (LAMP) test for diagnosis of uncomplicated malaria in endemic areas: a meta-analysis of diagnostic test accuracy.

Authors:  Denesh Selvarajah; Cho Naing; Norah Htet Htet; Joon Wah Mak
Journal:  Malar J       Date:  2020-06-19       Impact factor: 2.979

7.  Comparison of real time and malachite-green based loop-mediated isothermal amplification assays for the detection of Plasmodium vivax and P. falciparum.

Authors:  Keare A Barazorda; Carola J Salas; Danett K Bishop; Naomi Lucchi; Hugo O Valdivia
Journal:  PLoS One       Date:  2020-06-11       Impact factor: 3.240

8.  Poor Diagnostic Performance of a Species-Specific Loop-Mediated Isothermal Amplification (LAMP) Platform for Malaria.

Authors:  Hans Kollenda; Ralf Matthias Hagen; Miriam Hanke; Sandra Rojak; Rebecca Hinz; Lars Wassill; Sven Poppert; Egbert Tannich; Hagen Frickmann
Journal:  Eur J Microbiol Immunol (Bp)       Date:  2018-09-28

Review 9.  Loop-mediated isothermal amplification (LAMP): a versatile technique for detection of micro-organisms.

Authors:  Y-P Wong; S Othman; Y-L Lau; S Radu; H-Y Chee
Journal:  J Appl Microbiol       Date:  2018-02-12       Impact factor: 3.772

10.  Development of a multiplex Loop-Mediated Isothermal Amplification (LAMP) assay for on-site diagnosis of SARS CoV-2.

Authors:  Woong Sik Jang; Da Hye Lim; Jung Yoon; Ahran Kim; Minsup Lim; Jeonghun Nam; Richard Yanagihara; Sook-Won Ryu; Bo Kyeung Jung; Nam-Hee Ryoo; Chae Seung Lim
Journal:  PLoS One       Date:  2021-03-03       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.