| Literature DB >> 28348940 |
Harminder Singh1, Walid I Essayed2, Sayantan Deb3, Caitlin Hoffman2, Theodore H Schwartz4.
Abstract
INTRODUCTION: We describe the feasibility of using minimally invasive robotic laser interstitial thermotherapy (LITT) for achieving an anterior two-thirds as well as a complete corpus callosotomy.Entities:
Keywords: corpus callosotomy; laser interstitial thermotherapy; minimally invasive
Year: 2017 PMID: 28348940 PMCID: PMC5346016 DOI: 10.7759/cureus.1021
Source DB: PubMed Journal: Cureus ISSN: 2168-8184
Figure 1Trajectory planning of the anterior probe on Brainlab software. The distance from the tip of the probe to the inferior boundary of the splenium is measured.
Figure 2Trajectory planning of the posterior probe on Brainlab software. The distance of the tip of the probe to the inferior boundary of the genu is measured. Also, the distance from the genu to the entry point of the probe into the corpus callosum is measured.
Figure 3Artist rendition showing the entry point measurements of the anterior and posterior probes on the cranium. The anterior measurements are made from the nasion and midline. The posterior measurements are made from the torcula, the coronal suture, and midline.
Figure 4Placement of the posterior probe along the corpus callosum for an anterior two-thirds callosotomy. The probe is slowly retracted back as multiple thermal burns are executed (with MRI guidance) to cover the desired length of the corpus callosum.
Posterior trajectory entry point measurements (in cm).
| Above the Torcula | Behind the Coronal Suture | From the Midline | |
| 1 | 7.3 | 10.8 | 3.5 |
| 2 | 9.4 | 11 | 2.9 |
| 3 | 11.2 | 10.4 | 3.5 |
| 4 | 10.1 | 11.7 | 3.2 |
| 5 | 9.1 | 11.4 | 3.8 |
| 6 | 8.7 | 12.1 | 3.3 |
| 7 | 9.6 | 11.2 | 4.1 |
| 8 | 8.2 | 9.6 | 3.8 |
| 9 | 9.1 | 9.7 | 4.2 |
| 10 | 9.2 | 8.3 | 4.1 |
| Mean | 9.19 | 10.62 | 3.64 |
Corpus callosum (CC) entry point and distal measurements from the tip of the anterior and posterior probes (in cm). See Figure 1 and Figure 2 for illustration.
| Posterior Trajectory | Anterior Trajectory | ||
| Distance from genu to entry of probe into CC | Distance from probe tip to genu | Distance from probe tip to splenium | |
| 1 | 4.25 | 1.49 | 0.62 |
| 2 | 4.26 | 1.41 | 0.97 |
| 3 | 4.21 | 1.39 | 1.05 |
| 4 | 3.81 | 1.27 | 0.72 |
| 5 | 3.70 | 1.61 | 1.19 |
| 6 | 4.70 | 1.04 | 0.62 |
| 7 | 3.41 | 1.32 | 1.03 |
| 8 | 4.18 | 1.45 | 0.82 |
| 9 | 4.62 | 1.63 | 1.11 |
| 10 | 3.85 | 1.72 | 1.32 |
| Mean | 4.09 | 1.43 | 0.94 |
Figure 5Placement of the anterior probe along the corpus callosum for a posterior one-third callosotomy.
Anterior trajectory entry point measurements (in cm).
| From the Nasion | From the Midline | |
| 1 | 8.2 | 2.9 |
| 2 | 10.3 | 2.5 |
| 3 | 9.8 | 3.1 |
| 4 | 8.2 | 3.7 |
| 5 | 7.6 | 3.9 |
| 6 | 9.6 | 4.2 |
| 7 | 8.8 | 3.5 |
| 8 | 9.3 | 4.1 |
| 9 | 9.3 | 3.2 |
| 10 | 9.9 | 2.5 |
| Mean | 9.1 | 3.36 |