Literature DB >> 28347158

Effective dose in low-dose CT compared with radiography for templating of total hip arthroplasty.

Mats Geijer1,2, Gustav Rundgren2, Lars Weber2,3, Gunnar Flivik2,4.   

Abstract

Background Recently, total hip arthroplasty (THA) has come to focus on restoration of individual anatomy including femoral neck anteversion and global offset (femoral and acetabular offset). Three-dimensional (3D) computed tomography (CT) data could provide a better basis for preoperative templating. The use of CT has been hampered by high radiation dose. Purpose To evaluate the effective dose used in pelvis and hip CT for THA templating. Material and Methods CT data from two clinical trials of THA were evaluated for CT scan length and volume CT dose index (CTDIvol). The effective doses from hip-knee-ankle CT and pelvis and hip radiography were compared. Conversion factors for effective dose for radiography were calculated using the PCXMC software. Results A reduced dose CT protocol for pelvis imaging gave a substantial dose reduction compared with standard CT, while maintaining sufficient image quality. Between the two clinical trials there was a significant reduction in effective CT dose corresponding to changes in the CT protocol ( P < 0.01). The CT dose for the latter group was similar to, but nevertheless significantly higher than for, radiography ( P < 0.01). However, in the latter group the theoretical minimum dose for CT, using the minimum scan length required by the templating software, was equal to the dose from radiography. Conclusion Although the CT dose remained higher than for radiography, potential reductions in scan length could reduce the dose further so that CT would have a comparable level of risk to radiography with the added benefit of 3D templating.

Entities:  

Keywords:  X-ray computed tomography (CT); hip arthroplasty; radiation dose; radiography

Mesh:

Year:  2017        PMID: 28347158     DOI: 10.1177/0284185117693462

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  7 in total

1.  Low-Dose Computed Tomography Reduces Radiation Exposure by 90% Compared With Traditional Computed Tomography Among Patients Undergoing Hip-Preservation Surgery.

Authors:  Alvin W Su; Travis J Hillen; Eric P Eutsler; Asheesh Bedi; James R Ross; Christopher M Larson; John C Clohisy; Jeffrey J Nepple
Journal:  Arthroscopy       Date:  2019-04-12       Impact factor: 4.772

2.  Pre- and postoperative offset and femoral neck version measurements and validation using 3D computed tomography in total hip arthroplasty.

Authors:  Mats Geijer; Sverrir Kiernan; Martin Sundberg; Gunnar Flivik
Journal:  Acta Radiol Open       Date:  2020-10-08

3.  No Consequence for Lateral View X-Ray in Displaced Proximal Femoral Fractures in the Elderly.

Authors:  Christian Macke; Maic Werner; Lambert Herold; Olaf Krause; Tilmann Graulich; Jan-Dierk Clausen; Christian Krettek; Emmanouil Liodakis
Journal:  Front Surg       Date:  2021-05-24

4.  Effect of symmetrical restoration for the migration of uncemented total hip arthroplasty: a randomized RSA study with 75 patients and 5-year follow-up.

Authors:  Sverrir Kiernan; Mats Geijer; Martin Sundberg; Gunnar Flivik
Journal:  J Orthop Surg Res       Date:  2020-06-17       Impact factor: 2.359

5.  Geometrical restoration during total hip arthroplasty is related to change in gait pattern - a study based on computed tomography and three-dimensional gait analysis.

Authors:  A-C Esbjörnsson; S Kiernan; L Mattsson; G Flivik
Journal:  BMC Musculoskelet Disord       Date:  2021-04-20       Impact factor: 2.362

Review 6.  Comparison of the accuracy of 2D and 3D templating methods for planning primary total hip replacement: a systematic review and meta-analysis.

Authors:  Habeeb Bishi; Joshua B V Smith; Vipin Asopa; Richard E Field; Chao Wang; David H Sochart
Journal:  EFORT Open Rev       Date:  2022-01-11

Review 7.  The development of musculoskeletal radiology for 100 years as presented in the pages of Acta Radiologica.

Authors:  Mats Geijer; Fatih Inci; Nektarios Solidakis; Pawel Szaro; Bariq Al-Amiry
Journal:  Acta Radiol       Date:  2021-10-19       Impact factor: 1.990

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.