Very high-energy electron (VHEE) beams in radiation therapy; Treatment plan comparison between VHEE, VMAT, and PPBS.

Emil Schüler1, Kjell Eriksson2, Elin Hynning2, Steven L Hancock1, Susan M Hiniker1, Magdalena Bazalova-Carter3, Tony Wong4, Quynh-Thu Le1, Billy W Loo1, Peter G Maxim1.   

Abstract

PURPOSE: The aim of this study was to evaluate the performance of very high-energy electron beams (VHEE) in comparison to clinically derived treatment plans generated with volumetric modulated arc therapy (VMAT) and proton pencil beam scanning (PPBS) technology. We developed a custom optimization script that could be applied automatically across modalities to eliminate operator bias during IMRT optimization.
METHODS: Four clinical cases were selected (prostate cancer, lung cancer, pediatric brain tumor, and head and neck cancer (HNC)). The VHEE beams were calculated in the EGSnrc/DOSXYZnrc Monte Carlo code for 100 and 200 MeV beams. Treatment plans with VHEE, VMAT, and PPBS were optimized in a research version of RayStation using an in-house developed script to minimize operator bias between the different techniques.
RESULTS: The in-house developed script generated similar or superior plans to the clinically used plans. In the comparisons between the modalities, the integral dose was lowest for the PPBS-generated plans in all cases. For the prostate case, the 200 MeV VHEE plan showed reduced integral dose and reduced organ at risk (OAR) dose compared to the VMAT plan. For all other cases, both the 100 and the 200 MeV VHEE plans were superior to the VMAT plans, and the VHEE plans showed better conformity and lower spinal cord dose in the pediatric brain case and lower brain stem dose in the HNC case when compared to the PPBS plan.
CONCLUSIONS: The automated optimization developed in this study generated similar or superior plans as compared to the clinically used plan and represents an unbiased approach to compare treatment plans generated for different modalities. In the present study, we also show that VHEE plans are similar or superior to VMAT plans with reduced mean OAR dose and increased target conformity for a variety of clinical cases, and VHEE plans can even achieve reductions in OAR doses compared to PPBS plans for shallow targets. With increased VHEE energy, better conformity and even higher reductions in mean OAR doses are achieved. On the whole, VHEE was intermediate between photon VMAT and PPBS for OAR sparing.
© 2017 American Association of Physicists in Medicine.

Entities:  

Keywords:  comparative treatment planning; conformity index; integral dose; proton beam therapy; treatment planning; very high-energy electrons

Mesh:

Year:  2017        PMID: 28339108     DOI: 10.1002/mp.12233

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  10 in total

Review 1.  Expanding the therapeutic index of radiation therapy by normal tissue protection.

Authors:  Pierre Montay-Gruel; Lydia Meziani; Chakradhar Yakkala; Marie-Catherine Vozenin
Journal:  Br J Radiol       Date:  2018-07-02       Impact factor: 3.039

Review 2.  Ultra-high dose rate electron beams and the FLASH effect: From preclinical evidence to a new radiotherapy paradigm.

Authors:  Emil Schüler; Munjal Acharya; Pierre Montay-Gruel; Billy W Loo; Marie-Catherine Vozenin; Peter G Maxim
Journal:  Med Phys       Date:  2022-01-19       Impact factor: 4.506

3.  Ultra-high dose rate radiation production and delivery systems intended for FLASH.

Authors:  Jonathan Farr; Veljko Grilj; Victor Malka; Srinivasan Sudharsan; Marco Schippers
Journal:  Med Phys       Date:  2022-05-05       Impact factor: 4.506

4.  Initial Steps Towards a Clinical FLASH Radiotherapy System: Pediatric Whole Brain Irradiation with 40 MeV Electrons at FLASH Dose Rates.

Authors:  Dylan Yamabe Breitkreutz; Muhammad Shumail; Karl K Bush; Sami G Tantawi; Peter G Maxime; Billy W Loo
Journal:  Radiat Res       Date:  2020-12-01       Impact factor: 2.841

5.  The challenge of ionisation chamber dosimetry in ultra-short pulsed high dose-rate Very High Energy Electron beams.

Authors:  M McManus; F Romano; N D Lee; W Farabolini; A Gilardi; G Royle; H Palmans; A Subiel
Journal:  Sci Rep       Date:  2020-06-03       Impact factor: 4.379

Review 6.  Ultra-High Dose Rate (FLASH) Radiotherapy: Silver Bullet or Fool's Gold?

Authors:  Joseph D Wilson; Ester M Hammond; Geoff S Higgins; Kristoffer Petersson
Journal:  Front Oncol       Date:  2020-01-17       Impact factor: 6.244

7.  A focused very high energy electron beam for fractionated stereotactic radiotherapy.

Authors:  Kristoffer Svendsen; Diego Guénot; Jonas Björklund Svensson; Kristoffer Petersson; Anders Persson; Olle Lundh
Journal:  Sci Rep       Date:  2021-03-12       Impact factor: 4.379

8.  Deep Seated Tumour Treatments With Electrons of High Energy Delivered at FLASH Rates: The Example of Prostate Cancer.

Authors:  Alessio Sarti; Patrizia De Maria; Giuseppe Battistoni; Micol De Simoni; Cinzia Di Felice; Yunsheng Dong; Marta Fischetti; Gaia Franciosini; Michela Marafini; Francesco Marampon; Ilaria Mattei; Riccardo Mirabelli; Silvia Muraro; Massimiliano Pacilio; Luigi Palumbo; Loredana Rocca; Damiana Rubeca; Angelo Schiavi; Adalberto Sciubba; Vincenzo Tombolini; Marco Toppi; Giacomo Traini; Antonio Trigilio; Vincenzo Patera
Journal:  Front Oncol       Date:  2021-12-23       Impact factor: 6.244

9.  Determination of the ion collection efficiency of the Razor Nano Chamber for ultra-high dose-rate electron beams.

Authors:  Marco Cavallone; Patrik Gonçalves Jorge; Raphaël Moeckli; Claude Bailat; Alessandro Flacco; Yolanda Prezado; Rachel Delorme
Journal:  Med Phys       Date:  2022-05-20       Impact factor: 4.506

10.  First theoretical determination of relative biological effectiveness of very high energy electrons.

Authors:  Rachel Delorme; Thongchai A M Masilela; Camille Etoh; François Smekens; Yolanda Prezado
Journal:  Sci Rep       Date:  2021-05-27       Impact factor: 4.379

  10 in total