Literature DB >> 28333041

Characterization of 176Lu background in LSO-based PET scanners.

Maurizio Conti1, Lars Eriksson, Harold Rothfuss, Therese Sjoeholm, David Townsend, Göran Rosenqvist, Thomas Carlier.   

Abstract

LSO and LYSO are today the most common scintillators used in positron emission tomography. Lutetium contains traces of 176Lu, a radioactive isotope that decays β - with a cascade of γ photons in coincidence. Therefore, Lutetium-based scintillators are characterized by a small natural radiation background. In this paper, we investigate and characterize the 176Lu radiation background via experiments performed on LSO-based PET scanners. LSO background was measured at different energy windows and different time coincidence windows, and by using shields to alter the original spectrum. The effect of radiation background in particularly count-starved applications, such as 90Y imaging, is analysed and discussed. Depending on the size of the PET scanner, between 500 and 1000 total random counts per second and between 3 and 5 total true coincidences per second were measured in standard coincidence mode. The LSO background counts in a Siemens mCT in the standard PET energy and time windows are in general negligible in terms of trues, and are comparable to that measured in a BGO scanner of similar size.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28333041     DOI: 10.1088/1361-6560/aa68ca

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  Validation of a computational chain from PET Monte Carlo simulations to reconstructed images.

Authors:  Philip Kalaitzidis; Johan Gustafsson; Cecilia Hindorf; Michael Ljungberg
Journal:  Heliyon       Date:  2022-04-21

2.  Understanding the intrinsic radioactivity energy spectrum from 176Lu in LYSO/LSO scintillation crystals.

Authors:  H Alva-Sánchez; A Zepeda-Barrios; V D Díaz-Martínez; T Murrieta-Rodríguez; A Martínez-Dávalos; M Rodríguez-Villafuerte
Journal:  Sci Rep       Date:  2018-11-23       Impact factor: 4.379

3.  Simultaneous emission and attenuation reconstruction in time-of-flight PET using a reference object.

Authors:  Pablo García-Pérez; Samuel España
Journal:  EJNMMI Phys       Date:  2020-01-13

4.  Yttrium-90 TOF-PET-Based EUD Predicts Response Post Liver Radioembolizations Using Recommended Manufacturer FDG Reconstruction Parameters.

Authors:  Michel Hesse; Philipe d'Abadie; Renaud Lhommel; Francois Jamar; Stephan Walrand
Journal:  Front Oncol       Date:  2021-10-05       Impact factor: 6.244

5.  Precision dosimetry in yttrium-90 radioembolization through CT imaging of radiopaque microspheres in a rabbit liver model.

Authors:  E Courtney Henry; Matthew Strugari; George Mawko; Kimberly Brewer; David Liu; Andrew C Gordon; Jeffrey N Bryan; Charles Maitz; Robert Abraham; S Cheenu Kappadath; Alasdair Syme
Journal:  EJNMMI Phys       Date:  2022-03-21

6.  A CT-less approach to quantitative PET imaging using the LSO intrinsic radiation for long-axial FOV PET scanners.

Authors:  Mohammadreza Teimoorisichani; Vladimir Panin; Harold Rothfuss; Hasan Sari; Axel Rominger; Maurizio Conti
Journal:  Med Phys       Date:  2021-12-10       Impact factor: 4.506

7.  Lutetium background radiation in total-body PET-A simulation study on opportunities and challenges in PET attenuation correction.

Authors:  Negar Omidvari; Li Cheng; Edwin K Leung; Yasser G Abdelhafez; Ramsey D Badawi; Tianyu Ma; Jinyi Qi; Simon R Cherry
Journal:  Front Nucl Med       Date:  2022-08-10

8.  Coincidence energy spectra due to the intrinsic radioactivity of LYSO scintillation crystals.

Authors:  Francisco Eduardo Enríquez-Mier-Y-Terán; Ana Saret Ortega-Galindo; Tirso Murrieta-Rodríguez; Mercedes Rodríguez-Villafuerte; Arnulfo Martínez-Dávalos; Héctor Alva-Sánchez
Journal:  EJNMMI Phys       Date:  2020-04-15
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.