Literature DB >> 28330757

Does new instrumentation improve radiologic alignment of the Oxford® medial unicompartmental knee arthroplasty?

Ki-Mo Jang1, Hong Chul Lim2, Seung-Beom Han1, Chandong Jeong3, Seul-Gi Kim1, Ji-Hoon Bae4.   

Abstract

BACKGROUND: A new instrument system has been introduced to improve the accuracy and reproducibility of implant positioning in Oxford® unicompartmental knee arthroplasty (UKA). This study aimed to determine if the new instrumentation could improve postoperative implant positioning and limb alignment, and reduce the occurrence of outliers in Oxford® UKA.
METHODS: A total of 77 cases of Oxford® UKA with the new instrumentation were included. Individual matching for the conventional instrument group was performed according to age, sex, and body mass index. Postoperative radiological variables, including the hip-knee-ankle angle and the varus/valgus and flexion/extension angles of the femoral and tibial implants, were measured and compared between the new instrumentation group and the conventional group. The outliers in implant positions and postoperative complications were also compared.
RESULTS: No significant between-group differences were observed in terms of lower limb alignment and tibial implant alignment. However, statistically significant differences were identified in the varus/valgus and flexion/extension angles of the femoral implant (P=0.01 and P<0.001, respectively). More outliers were observed in the flexion/extension angles of the femoral and tibial implants in the new instrumentation group. Eight meniscal bearing dislocations and three lateral compartmental degenerative changes were found in the conventional group, while there were two meniscal bearing dislocations in the new instrumentation group during the study period.
CONCLUSION: The present study did not confirm any benefit of the new instrument system in terms of postoperative limb alignment, positioning of the implant, or reducing outliers beyond the use of the conventional instruments.
Copyright © 2017 Elsevier B.V. All rights reserved.

Keywords:  Knee; Medial compartmental osteoarthritis; Microplasty instrumentation; Oxford® knee replacement; Unicompartmental knee arthroplasty

Mesh:

Year:  2017        PMID: 28330757     DOI: 10.1016/j.knee.2017.02.001

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  4 in total

1.  What future in the treatment of osteochondral knee defects?

Authors:  Riccardo D'Ambrosi; Vincenza Ragone; Nicola Ursino
Journal:  Ann Transl Med       Date:  2018-12

2.  Early Results of Oxford Mobile Bearing Medial Unicompartmental Knee Replacement (UKR) with the Microplasty Instrumentation: An Indian Experience.

Authors:  Sahil Gaba; Naman Wahal; Deepak Gautam; Hemant Pandit; Vijay Kumar; Rajesh Malhotra
Journal:  Arch Bone Jt Surg       Date:  2018-07

3.  Unicompartmental Knee Arthroplasty.

Authors:  Kyung Tae Kim
Journal:  Knee Surg Relat Res       Date:  2018-03-01

Review 4.  Does new instrument for Oxford unicompartmental knee arthroplasty improve short-term clinical outcome and component alignment? A meta-analysis.

Authors:  Xiao Wei Sun; Fei Fan Lu; Kun Zou; Mao Hong; Qi Dong Zhang; Wan Shou Guo
Journal:  J Orthop Surg Res       Date:  2020-09-07       Impact factor: 2.359

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.