Literature DB >> 28327469

Total body irradiation with a compensator fabricated using a 3D optical scanner and a 3D printer.

So-Yeon Park1, Jung-In Kim, Yoon Ha Joo, Jung Chan Lee, Jong Min Park.   

Abstract

We propose bilateral total body irradiation (TBI) utilizing a 3D printer and a 3D optical scanner. We acquired surface information of an anthropomorphic phantom with the 3D scanner and fabricated the 3D compensator with the 3D printer, which could continuously compensate for the lateral missing tissue of an entire body from the beam's eye view. To test the system's performance, we measured doses with optically stimulated luminescent dosimeters (OSLDs) as well as EBT3 films with the anthropomorphic phantom during TBI without a compensator, conventional bilateral TBI, and TBI with the 3D compensator (3D TBI). The 3D TBI showed the most uniform dose delivery to the phantom. From the OSLD measurements of the 3D TBI, the deviations between the measured doses and the prescription dose ranged from  -6.7% to 2.4% inside the phantom and from  -2.3% to 0.6% on the phantom's surface. From the EBT3 film measurements, the prescription dose could be delivered to the entire body of the phantom within  ±10% accuracy, except for the chest region, where tissue heterogeneity is extreme. The 3D TBI doses were much more uniform than those of the other irradiation techniques, especially in the anterior-to-posterior direction. The 3D TBI was advantageous, owing to its uniform dose delivery as well as its efficient treatment procedure.

Mesh:

Year:  2017        PMID: 28327469     DOI: 10.1088/1361-6560/aa6866

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Commissioning of total body irradiation using plastic bead bags.

Authors:  Yuichi Akino; Shintaro Maruoka; Katsuyuki Yano; Hiroshi Abe; Fumiaki Isohashi; Yuji Seo; Keisuke Tamari; Takero Hirata; Manabu Kawakami; Yoshiki Nakae; Yoshihiro Tanaka; Kazuhiko Ogawa
Journal:  J Radiat Res       Date:  2020-11-16       Impact factor: 2.724

2.  A modern mold room: Meshing 3D surface scanning, digital design, and 3D printing with bolus fabrication.

Authors:  David Kiyoshi Sasaki; Philip McGeachy; Jorge E Alpuche Aviles; Boyd McCurdy; Rashmi Koul; Arbind Dubey
Journal:  J Appl Clin Med Phys       Date:  2019-08-27       Impact factor: 2.102

3.  Automatic treatment planning for VMAT-based total body irradiation using Eclipse scripting.

Authors:  Jose R Teruel; Sameer Taneja; Paulina E Galavis; K Sunshine Osterman; Allison McCarthy; Martha Malin; Naamit K Gerber; Christine Hitchen; David L Barbee
Journal:  J Appl Clin Med Phys       Date:  2021-02-10       Impact factor: 2.102

4.  Low-cost optical scanner and 3-dimensional printing technology to create lead shielding for radiation therapy of facial skin cancer: First clinical case series.

Authors:  Ankur Sharma; David Sasaki; Daniel W Rickey; Ahmet Leylek; Chad Harris; Kate Johnson; Jorge E Alpuche Aviles; Boyd McCurdy; Andy Egtberts; Rashmi Koul; Arbind Dubey
Journal:  Adv Radiat Oncol       Date:  2018-02-14
  4 in total