| Literature DB >> 28326316 |
Aline P Oliveira1, Geyssa Ferreira Andrade1, Bianca S O Mateó1, Juliana Naozuka1.
Abstract
Beans (Phaseolus vulgaris L.) are among the main sources of protein and minerals. The cooking of the grains is imperative, due to reduction of the effect of some toxic and antinutritional substances, as well as increase of protein digestibility. In this study, the effects of cooking on albumins, globulins, prolamins, and glutelins concentration and determination of Fe associated with proteins for different beans varieties and on phaseolin concentration in common and black beans were evaluated. Different extractant solutions (water, NaCl, ethanol, and NaOH) were used for extracting albumins, globulins, prolamins, and glutelins, respectively. For the phaseolin separation NaOH, HCl, and NaCl were used. The total concentration of proteins was determined by Bradford method; Cu and Fe associated with phaseolin and other proteins were obtained by graphite furnace atomic absorption spectrometry and by flame atomic absorption spectrometry, respectively. Cooking promoted a negative effect on (1) the proteins concentrations (17 (glutelin) to 95 (albumin) %) of common beans and (2) phaseolin concentration (90%) for common and black beans. Fe associated with albumin, prolamin, and glutelin was not altered. In Fe and Cu associated with phaseolin there was an increase of 20 and 37% for the common and black varieties, respectively.Entities:
Year: 2017 PMID: 28326316 PMCID: PMC5343270 DOI: 10.1155/2017/5957178
Source DB: PubMed Journal: Int J Food Sci ISSN: 2314-5765
Instrumental parameters and heating program for Fe and Cu determination by GF AAS.
| Instrumental parameters | Fea | Cub | |
|---|---|---|---|
|
| 248.3 | 324.8 | |
| Slit/nm | 0.8 | 0.8 | |
| I/mA | 4.0 | 4.0 | |
|
| |||
| Heating program | |||
|
| |||
| Step | T/°C | Ramp/°C s−1 | Hold/s |
|
| |||
| Drying | 130 | 5 | 20 |
| Pyrolysis | 1200a/1000b | 100 | 15 |
| Atomization | 2300 | 2300 | 5 |
| Cleaning | 2500 | 1200 | 2 |
Characteristic parameters of the analytical calibration curve and LOD obtained for proteins determination by Bradford method.
| Linear range ( |
|
| Sensibility | Analytical blank | LOD ( | LOQ ( | |
|---|---|---|---|---|---|---|---|
| Sequential extraction | 2–12 | 0.9935 | 0.9871 | 0.049 | Water | 0.53 | 1.60 |
| NaCl | 0.55 | 1.66 | |||||
| Ethanol | 0.56 | 1.67 | |||||
| NaOH | 0.54 | 1.62 |
Proteins concentrations in different varieties of Phaseolus beans (raw and cooked).
| Variety | Condition | Concentration (mg g−1) ± standard deviation ( | |||
|---|---|---|---|---|---|
| Albumins | Globulins | Prolamins | Glutelins | ||
| Common | Raw | 1.2 ± 0.1 | 1.2 ± 0.1 | 1.3 ± 0.1 | 14 ± 1 |
| Cooked | 0.99 ± 0.01 | 0.94 ± 0.01 | 0.98 ± 0.01 | 0.74 ± 0.01 | |
| Black | Raw | 1.3 ± 0.1 | 1.2 ± 0.1 | 1.2 ± 0.1 | 2.8 ± 0.2 |
| Cooked | 0.71 ± 0.01 | 0.76 ± 0.01 | 0.64 ± 0.01 | 2.2 ± 0.2 | |
| Rosinha | Raw | 0.99 ± 0.01 | 1.3 ± 0.2 | 0.87 ± 0.01 | 6.1 ± 0.1 |
| Cooked | 0.92 ± 0.01 | 0.81 ± 0.01 | 0.85 ± 0.01 | 3.1 ± 0.3 | |
| Bolinha | Raw | 0.77 ± 0.01 | 0.73 ± 0.01 | 0.83 ± 0.01 | 14 ± 1 |
| Cooked | 0.99 ± 0.01 | 0.94 ± 0.01 | 0.97 ± 0.01 | 2.3 ± 0.1 | |
| Rajado | Raw | 0.95 ± 0.01 | 0.83 ± 0.01 | 0.87 ± 0.01 | 1.9 ± 0.1 |
| Cooked | 1.1 ± 0.1 | 0.98 ± 0.01 | 0.85 ± 0.01 | 0.72 ± 0.01 | |
| Fradinho | Raw | 1.0 ± 0.1 | 1.1 ± 0.1 | 1.04 ± 0.01 | 6.3 ± 0.1 |
| Cooked | 1.1 ± 0.1 | 0.98 ± 0.01 | 0.95 ± 0.01 | 4.5 ± 0.1 | |
| Jalo | Raw | 0.72 ± 0.01 | 1.1 ± 0.1 | 0.96 ± 0.01 | 2.4 ± 0.2 |
| Cooked | 1.1 ± 0.1 | 0.97 ± 0.01 | 0.89 ± 0.01 | 1.7 ± 0.1 | |
Characteristic parameters of the analytical calibration curve, LOD, and LOQ obtained for Fe determination by F AAS.
|
| Linear range (mg L−1) |
| LOD ( | LOQ ( |
|---|---|---|---|---|
| 259 | 0.25–3.0 | 0.9961 | 0.18 (albumins) | 0.54 (albumins) |
| 0.54 (globulins) | 1.62 (globulins) | |||
| 1.64 (prolamins) | 4.92 (prolamins) | |||
| 1.68 (glutelins) | 5.04 (glutelins) |
Iron concentration in albumins, globulins, prolamins, and glutelins of Phaseolus beans.
| Variety | Condition | Concentration ( | |||
|---|---|---|---|---|---|
| Albumins | Globulins | Prolamins | Glutelins | ||
| Common | Raw | 20 ± 1 | 4 ± 2 | 3 ± 1 | 9 ± 1 |
| Cooked | 25 ± 2 | 12 ± 3 | 13 ± 2 | 8 ± 1 | |
| Black | Raw | 21 ± 1 | 10 ± 1 | 10 ± 1 | 20 ± 6 |
| Cooked | 30 ± 2 | 10 ± 2 | 17 ± 1 | 50 ± 5 | |
| Rosinha | Raw | 27 ± 2 | 10 ± 2 | 17 ± 1 | 40 ± 5 |
| Cooked | 30 ± 1 | 16 ± 4 | 14 ± 2 | 40 ± 4 | |
| Bolinha | Raw | 30 ± 1 | 11 ± 1 | 13 ± 1 | 22 ± 6 |
| Cooked | 25 ± 1 | 8 ± 1 | 24 ± 1 | 36 ± 4 | |
| Rajado | Raw | 23 ± 1 | 8 ± 3 | 11 ± 3 | 27 ± 4 |
| Cooked | 24 ± 1 | 6 ± 2 | 9 ± 1 | 6 ± 2 | |
| Fradinho | Raw | 21 ± 1 | 7 ± 2 | 11 ± 3 | 24 ± 13 |
| Cooked | 23 ± 2 | 7 ± 1 | 10 ± 3 | 11 ± 4 | |
| Jalo | Raw | 22 ± 1 | 4 ± 1 | 9 ± 2 | 12 ± 5 |
| Cooked | 26 ± 1 | 9 ± 2 | 15 ± 2 | 34 ± 9 | |
Concentrations of precipitated proteins without phaseolin and phaseolin in the common and black beans.
| Concentration (mg g−1) ± standard deviation ( | ||||
|---|---|---|---|---|
| Common | Black | |||
| Raw | Cooked | Raw | Cooked | |
| Precipitated proteins without phaseolin | 5.8 ± 0.1 | 2.64 ± 0.01 | 3.31 ± 0.04 | 2.7 ± 0.1 |
| Phaseolin | 0.12 ± 0.01 | 0.013 ± 0.001 | 0.10 ± 0.01 | 0.009 ± 0.001 |
Characteristic parameters of the analytical calibration curve, LOD, and LOQ obtained for Cu and Fe determination by GF AAS.
| Linear range (mg L−1) |
| Sensibility | LOD (ng g−1) | LOQ (ng g−1) | |
|---|---|---|---|---|---|
| Cu | 10–80 | 0.9881 | 0.0043 | 0.47 | 1.41 |
| Fe | 10–80 | 0.9956 | 0.0055 | 0.05 | 0.16 |
Cu and Fe concentration associated with precipitated proteins without phaseolin and phaseolin.
| Concentration ( | ||||
|---|---|---|---|---|
| Fe | Cu | |||
| Raw | Cooked | Raw | Cooked | |
|
| ||||
| Precipitated proteins without phaseolin | 8.9 ± 0.1 | 17 ± 1 | 4.2 ± 0.9 | 2.6 ± 0.4 |
| Phaseolin | 3.2 ± 0.1 | 2.4 ± 0.1 | 0.72 ± 0.04 | 0.86 ± 0.03 |
|
| ||||
|
| ||||
| Precipitated proteins without phaseolin | 5.6 ± 0.3 | 14 ± 1 | 4.1 ± 0.5 | 1.8 ± 0.1 |
| Phaseolin | 2.9 ± 0.1 | 2.3 ± 0.1 | 0.84 ± 0.03 | 1.2 ± 0.1 |