Comparison of functional outcomes and patient-reported satisfaction between titanium and absorbable plates and screws for fixation of mandibular fractures: A one-year prospective study.

Maria Belén Leno1, Stanley Yung Liu1, Chien-Tzung Chen2, Han-Tsung Liao3.   

Abstract

PURPOSE: The aim of this study is to compare the 1-year functional outcomes and patient-reported satisfaction in treating mandibular fractures between resorbable and titanium fixation devices.
MATERIALS AND METHODS: A 1-year prospective study was conducted; 41 consecutive patients presenting with mandibular fractures were included. A resorbable system was used in 21 patients, while in 20 patients a titanium fixation device was used. Functional outcome was evaluated objectively at several time points (2, 4 and 6 weeks, 3 and 6 months, and 1 year after surgery). Bite forces over molars and incisors, mouth opening distance, occlusal status, operation time, fee for implants, bone healing and plate-associated complications were evaluated. Functional and overall satisfaction was measured by patients themselves subjectively.
RESULTS: A statistical difference was found only in maximal mouth opening and molar bite force, both greater for the titanium group in the 2-week time point, achieving comparable measurements in subsequent ones. This coincides with the patient-reported statistically lower satisfaction rates. The cost of the resorbable device was nearly 3 times more expensive than the titanium devices.
CONCLUSION: Resorbable fixation can achieve stability of bone healing at 1 year postoperatively, with functional and satisfaction outcomes comparable to those associated with titanium hardware from the fourth week postoperatively, while yielding unique advantages.
Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Biting forces; Mandibular fractures; Poly-L/DL-lactide; Resorbable fixation

Mesh:

Substances:

Year:  2017        PMID: 28318918     DOI: 10.1016/j.jcms.2017.01.034

Source DB:  PubMed          Journal:  J Craniomaxillofac Surg        ISSN: 1010-5182            Impact factor:   2.078


  5 in total

1.  Resorbable Implants for Mandibular Fracture Fixation: A Systematic Review and Meta-Analysis.

Authors:  Yehuda Chocron; Alain J Azzi; Sabrina Cugno
Journal:  Plast Reconstr Surg Glob Open       Date:  2019-08-30

2.  Disproportionate Effect of Sub-Micron Topography on Osteoconductive Capability of Titanium.

Authors:  Juri Saruta; Nobuaki Sato; Manabu Ishijima; Takahisa Okubo; Makoto Hirota; Takahiro Ogawa
Journal:  Int J Mol Sci       Date:  2019-08-18       Impact factor: 5.923

3.  A Newly Created Meso-, Micro-, and Nano-Scale Rough Titanium Surface Promotes Bone-Implant Integration.

Authors:  Masakazu Hasegawa; Juri Saruta; Makoto Hirota; Takashi Taniyama; Yoshihiko Sugita; Katsutoshi Kubo; Manabu Ishijima; Takayuki Ikeda; Hatsuhiko Maeda; Takahiro Ogawa
Journal:  Int J Mol Sci       Date:  2020-01-25       Impact factor: 5.923

4.  Are Magnesium Screws Proper for Mandibular Condyle Head Osteosynthesis?

Authors:  Marcin Kozakiewicz
Journal:  Materials (Basel)       Date:  2020-06-10       Impact factor: 3.623

5.  Bone Union Quality after Fracture Fixation of Mandibular Head with Compression Magnesium Screws.

Authors:  Marcin Kozakiewicz; Izabela Gabryelczak
Journal:  Materials (Basel)       Date:  2022-03-17       Impact factor: 3.623

  5 in total