Damage Identification on Vertebral Bodies During Compressive Loading Using Digital Image Correlation.

Hannah M Gustafson1, Angela D Melnyk, Gunter P Siegmund, Peter A Cripton.   

Abstract

MINI: Identifying fracture is important for understanding vertebral mechanics. Isolated cadaveric thoracolumbar vertebrae were compressed, and surface strains were measured using digital image correlation. Fracture locations from video analysis were qualitatively similar to the locations of high compressive strains and local damage occurred before the maximum force was reached. STUDY
DESIGN: Ex vivo compression experiments on isolated cadaveric vertebrae.
OBJECTIVE: To qualitatively compare the fracture locations identified in video analysis with the locations of high compressive strain measured with digital image correlation (DIC) on vertebral bodies and to evaluate the timing of local damage to the cortical shell relative to the global yield force. SUMMARY OF BACKGROUND DATA: In previous ex vivo experiments, cortical bone fracture has been identified using various methods including acoustic emission sensors, strain gages, video analysis, or force signals. These methods are, however, limited in their ability to detect the location and timing of fracture. We propose use of DIC, a noncontact optical technique that measures surface displacement, to quantify variables related to damage.
METHODS: Isolated thoracolumbar human cadaveric vertebral bodies (n = 6) were tested in compression to failure at a quasi-static rate, and the force applied was measured using a load cell. The surface displacement and strain were measured using DIC. Video analysis was performed to identify fractures.
RESULTS: The location of fractures identified in the video corresponded well with the locations of high compressive strain on the bone. Before reaching the global yield force, more than 10% of the DIC measurements reached a minimum principal strain of 1.0%, a previously reported threshold for cortical bone damage.
CONCLUSION: DIC measurements provide an objective measure that can be used to identify the location and timing of fractures during ex vivo vertebral experiments. This is important for understanding fracture mechanics and for validating vertebral computational models that incorporate failure. LEVEL OF EVIDENCE: N /A.

Entities:  

Mesh:

Year:  2017        PMID: 28306642     DOI: 10.1097/BRS.0000000000002156

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  3 in total

1.  A Three-Dimensional Cement Quantification Method for Decision Prediction of Vertebral Recompression after Vertebroplasty.

Authors:  Yanming Zhang; Tao Zhang; Xiang Ge; Yong Ma; Zhenduo Cui; Shuilin Wu; Yanqin Liang; Shengli Zhu; Zhaoyang Li
Journal:  Comput Math Methods Med       Date:  2022-05-12       Impact factor: 2.809

2.  Three-dimensional surface strain analyses of simulated defect and augmented spine segments: A biomechanical cadaveric study.

Authors:  Asghar Rezaei; Maryam Tilton; Hugo Giambini; Yong Li; Alexander Hooke; Alan L Miller Ii; Michael J Yaszemski; Lichun Lu
Journal:  J Mech Behav Biomed Mater       Date:  2021-04-23

Review 3.  Trabecular Architecture and Mechanical Heterogeneity Effects on Vertebral Body Strength.

Authors:  Joshua D Auger; Neilesh Frings; Yuanqiao Wu; Andre Gutierrez Marty; Elise F Morgan
Journal:  Curr Osteoporos Rep       Date:  2020-11-20       Impact factor: 5.096

  3 in total