Literature DB >> 28302305

Absolute or relative stability in minimal invasive plate osteosynthesis of simple distal meta or diaphyseal tibia fractures?

R Wenger1, F Oehme2, J Winkler2, S M Perren3, R Babst2, F J P Beeres4.   

Abstract

INTRODUCTION: Minimal invasive plate osteosynthesis in simple distal meta or diaphyseal tibia fractures can be applied using absolute (lag screw and neutralisation plate; LSN) or relative stability (bridge plate; BP). The primary aim of the study was to compare time to radiological union and time to full weight bearing in the two groups (LSN vs. BP). Reduction was performed either percutaneously or by a minimally open approach (mini open). Secondary aim was to analyse the number of complications between both groups.
METHODS: Retrospective single centre review of patients with a simple distal meta or diaphyseal tibia fracture operated with a Locking Compression Plate (LCP) between 2009 and 2015 in a Level one Trauma Centre. Postoperative radiographs were assessed in a standardised manner. Time to radiological fracture union and time to full weight bearing were observed. Callus index and postoperative complications were analysed.
RESULTS: Fifty-seven patients with a minimum follow-up of 6 months were analysed. Forty-eight patients had a shaft (AO/OTA Type 42) and nine a distal tibia fracture (AO/OTA Type 43). Forty patients were treated with using the LSN concept and 17 patients with the BP concept. Median time to radiological fracture union was statistically significant shorter (p=0.04) in the LSN group with 19 weeks compared to 27 weeks in the BP-group. Time to full weight bearing was 10 weeks in both groups. A total (including implant removal) of 35 reoperations were performed in the LSN-group and 18 in the BP-group. Wound healing disorders (deep surgical site infections) were seen less the LSN group in 3/40 (7.5%) compared to the BP-group with 3/17 (17.6%). In the LSN group, there was no statistical difference in time to union or weight bearing between a percutaneous or mini open approach.
CONCLUSION: Stable osteosynthesis of simple distal meta or diaphyseal tibia fractures leads to faster radiologic fracture healing without an increase in complications or number of revisions compared to bridge plating. If a percutaneous reduction is not feasible for the insertion of a lag screw, a mini-open approach does not lead to a delay in fracture healing.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Bridge plating; Lag screw; Locking compression plate; Minimal invasive plate osteosynthesis; Tibia fracture

Mesh:

Year:  2017        PMID: 28302305     DOI: 10.1016/j.injury.2017.03.005

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  8 in total

1.  Interfragmentary lag screw and locking plate combination in simple distal femoral fractures: A finite element analysis.

Authors:  Jun Zhang; Yan Wei; Guoding Li; Jian Wang; Youjia Xu
Journal:  Acta Orthop Traumatol Turc       Date:  2021-01       Impact factor: 1.511

2.  Finite element analysis of bone and implant stresses for customized 3D-printed orthopaedic implants in fracture fixation.

Authors:  Lina Yan; Joel Louis Lim; Jun Wei Lee; Clement Shi Hao Tia; Gavin Kane O'Neill; Desmond Y R Chong
Journal:  Med Biol Eng Comput       Date:  2020-02-19       Impact factor: 2.602

3.   Time until union in absolute vs. relative stability MIPO plating in simple humeral shaft fractures.

Authors:  Ignacio Rellán; Gerardo Luis Gallucci; Agustin Guillermo Donndorff; Pablo De Carli; Ezequiel Ernesto Zaidenberg; Marc Joseph Richard; Jorge Guillermo Boretto
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-03-29

4.  MIPO vs. intra-medullary nailing for extra-articular distal tibia fractures and the efficacy of intra-operative alignment control: a retrospective cohort of 135 patients.

Authors:  Nils Jan Bleeker; Nicole M van Veelen; Bryan J M van de Wall; Inger N Sierevelt; Björn-Christian Link; Reto Babst; Matthias Knobe; Frank J P Beeres
Journal:  Eur J Trauma Emerg Surg       Date:  2022-01-04       Impact factor: 2.374

5.  Union Following Biological and Rigid Fixations of Distal Tibia Extra-articular Fractures.

Authors:  Abdallah Abboud; Karim Masrouha; Tammam Hanna; Said Saghieh
Journal:  Arch Bone Jt Surg       Date:  2020-03

Review 6.  The biology and treatment of acute long-bones diaphyseal fractures: Overview of the current options for bone healing enhancement.

Authors:  Giuseppe Marongiu; Andrea Dolci; Marco Verona; Antonio Capone
Journal:  Bone Rep       Date:  2020-01-28

7.  Minimally invasive plate osteosynthesis for short oblique diaphyseal tibia fractures: does fracture site affect the outcomes?

Authors:  Gokay Eken; Cenk Ermutlu; Kemal Durak; Teoman Atici; Bartu Sarisozen; Adnan Cakar
Journal:  J Int Med Res       Date:  2020-10       Impact factor: 1.671

8.  Soft tissue complications in distal tibial fractures managed with medial locking plates: A myth or reality?

Authors:  Deepak Jain; Harpal Singh Selhi; Mohammad Yamin; Pankaj Mahindra
Journal:  J Clin Orthop Trauma       Date:  2017-07-03
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.