Literature DB >> 28300366

Internal dosimetry for radioembolization therapy with Yttrium-90 microspheres.

Maryam Fallahpoor1, Mehrshad Abbasi1, Ali Asghar Parach2, Faraz Kalantari3.   

Abstract

The absorbed doses in the liver and adjacent viscera in Yttrium-90 radioembolization therapy for metastatic liver lesions are not well-documented. We sought for a clinically practical way to determine the dosimetry of this advent treatment. Six different female XCAT BMIs and seven different male XCAT BMIs were generated. Using Monte Carlo GATE code simulation, the total of 100MBq 90 Y was deposited uniformly in the source organ, liver. Self-irradiation and absorbed doses in lung, kidney and bone marrow were calculated. The mean energy of Yittrium-90 (i.e., 0.937 MeV) was used. The S-values and equivalent doses in target organs were estimated. The dose absorbed in the liver was between 84 and 53 Gy and below the target of 80 to 150 Gy. The absorbed dose in the bone marrow, lungs, and kidneys are very low and below 0.1 , 0.4, and 0.5 Gy respectively. Our study indicates that larger activities than the conventional dose of 3 GBq may be both required and safe. Further confirmations in clinical settings are needed.
© 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

Entities:  

Keywords:  Yttrium-90; dosimetry; microsphere

Mesh:

Substances:

Year:  2017        PMID: 28300366      PMCID: PMC5689949          DOI: 10.1002/acm2.12042

Source DB:  PubMed          Journal:  J Appl Clin Med Phys        ISSN: 1526-9914            Impact factor:   2.102


Introduction

The treatment of inoperable liver metastases with microspheres and particles labeled with isotopes is a promising hope for a condition once was regarded untreatable.1, 2, 3, 4, 5 The procedure is evolving and the radiations to lungs, preserved liver parenchyma, and the bone marrow in repeated treatments are the limiting concern. Patient's dosimetry is possible with simulation methods before the initiation of the treatment or can be calculated after the treatment for follow‐up purposes. We previously used Monte Carlo code for certain conventional imaging and therapeutic agents including Technetium‐99m, Iodine‐131, and Samarium‐153 in different phantoms6, 7 and in patient. Recently 90Y became available to us and labeling of the microspheres and clinical trials are under development.8, 9, 10 There are different methods for internal dosimetry and imaging of the 90Y.11 In this study, we provide a radiation dose estimate to major target organs after treatment of liver metastases with the 90Y Microspheres. The results are important for us before proceeding to the clinical use of the therapeutic agent. We define the procedure so that internal dosimetry become practical for the future uses. We employed GATE (GEANT4 Application to Tomographic Emission)12 as a dedicated Mont Carlo code for nuclear medicine and XCAT13 as an up‐to‐date hybrid phantom.

Material and methods

Thirteen different total body XCAT phantoms including six female BMIs (18.6, 20.8, 22.1, 26.8, 30.3, and 34.7 kg/m2) and seven male BMIs (23.0, 24.9, 27.1, 28.3, 29.3, 34.5, and 35.8 kg/m2) were generated. The matrix dimensions were 128 × 128 × 600 with 0.3125 cm3 voxel sizes. We defined total activity of 100 MBq 90Y uniformly distributed in the liver as the source organ. Then, absorbed dose in four clinically important critical organs for the treatment by 90Y microspheres including liver, lung, kidney, and bone marrow were calculated. Simulations were performed with GATE, Monte Carlo code with the same method we previously documented.6 Among other physical interactions, attention has been given to various interactions of electron including Bremsstrahlung.14 The mean energy of 90Y, 0.937 MeV, was used for the beta particles. After dosimetry simulations with GATE, the output is two binary files containing the absorbed dose in voxels (in cGy) and the corresponding uncertainties respectively.15 We calculated the S‐values (in mGy/MBq‐s) for beta particles of 90Y according to Medical International Radiation Dose (MIRD) committee guideline.16 To report the results in a more familiar way, the corresponding amount of equivalent dose (in mSv/s) were shown as well (Fig. 1, 2, 3, 4).
Figure 1

The diagram of liver equivalent dose for different female BMIs.

Figure 2

The diagram of equivalent dose of lung, kidney, and bone marrow for different female BMIs.

Figure 3

The diagram of liver equivalent dose for different male BMIs.

Figure 4

The diagram of equivalent dose of lung, kidney and bone marrow for different male BMIs.

The diagram of liver equivalent dose for different female BMIs. The diagram of equivalent dose of lung, kidney, and bone marrow for different female BMIs. The diagram of liver equivalent dose for different male BMIs. The diagram of equivalent dose of lung, kidney and bone marrow for different male BMIs.

Results

The successful uniform distribution of the tracer within the liver and the visual depiction of the deposited dose in the target organs are depicted in Fig. 5. Also the radiation to the main target organs is presented in Table 1 in males and females. In all studied BMIs the radiation to the liver is remarkably higher than the lung and other target organs by the power of at least 100 (Fig. 1 and Fig. 3). For an effective half‐life of the 90Y which equals to its physical half‐life17 (i.e., 64.1 hours) and theoretical fixed administered dose of 3 GBq, the total radiation doses to the liver in different BMIs of female phantoms range between 84 and 54 Gy while the radiation to the lung ranges between 0.34 and 0.005 Gy. The radiation to the liver in male phantoms ranges between 64 and 53 Gy and the radiation to the lung between 0.26 and 0.004 Gy. The radiation to the kidneys varies between 0.48 to 0.08 in females and 0.43 to 0.05 in males. The highest bone marrow absorbed dose is below 0.1 Gy for an effective half‐life of the 90Y. The equivalent dose within the liver is generally about 1 mSiv/h while the dose to the bone marrow is below 0.003 mSiv/h and the equivalent dose to the kidney and lung is below 0.03 mSiv in females (Fig. 2) and 0.027 in males (Fig. 4).
Figure 5

A view of organs selected as source and target organs; liver is both source of total of 100MBq Yttrium‐90 (uniform distribution) and the target organ (a); dose absorption in the lungs (b), kidney (c), and bone marrow (d) in other target organs are also visually depicted.

Table 1

S‐values (mGy/MBq‐s) calculated from Yttrium‐90 in different female BMIs

Source organSexBMIsTarget organs
LiverLungKidneyBone marrow
LiverFemale18.61.2085e‐0041.6692e‐0085.1755e‐0071.2834e‐007
20.88.5090e‐0051.7210e‐0076.9404e‐0073.1386e‐008
22.19.2387e‐0052.5969e‐0072.8099e‐0074.6769e‐008
26.89.5030e‐0057.5511e‐0095.6558e‐0073.1865e‐008
30.38.6134e‐0053.0210e‐0071.2805e‐0071.1142e‐007
34.77.8204e‐0054.8910e‐0074.4929e‐0073.2973e‐008
Male23.08.6110e‐0052.7157e‐0073.3380e‐0077.1842e‐008
24.97.8633e‐0053.7746e‐0071.3852e‐0073.4974e‐008
27.19.2373e‐0051.9722e‐0076.2601e‐0076.0759e‐009
28.38.4301e‐0053.5794e‐0072.4988e‐0074.6876e‐008
29.36.6163e‐0056.0479e‐0093.9694e‐0071.7263e‐008
34.56.1598e‐0051.5001e‐0079.7855e‐0083.1512e‐008
35.86.5184e‐0054.1659e‐0087.1693e‐0084.3151e‐008
A view of organs selected as source and target organs; liver is both source of total of 100MBq Yttrium‐90 (uniform distribution) and the target organ (a); dose absorption in the lungs (b), kidney (c), and bone marrow (d) in other target organs are also visually depicted. S‐values (mGy/MBq‐s) calculated from Yttrium‐90 in different female BMIs

Discussion

We documented the dose to the liver and some critical organs after 90Y‐Microsphere therapy for liver metastases. The ranges of the absorbed doses in the liver are generally less than the target therapeutic dose for tumoricidal purposes of at least 80 Gy.1 We put the therapeutic dose homogeneously within the liver,18 but for the real practice one or more hepatic artery divisions could be catheterized19 and hence the extent of the radiation would be probably higher.1, 2 Certain calculation methods are available to estimate the radiation to tumor and normal liver parenchyma.20 With the same method using the patient's SPECT/CT data the exact radiation to the hepatic metastases could be calculated. Such data could be acquired by the injection of macroaggregated albumin tagged with 99mTc or 111indium before the administration of the therapeutic dose of 90Y‐Microspheres via the hepatic artery catheter.21 There are methods for internal dosimetry based on MIRD formalism. In these methods, the activity deposition is concrete and less‐flexible to match with the variations of the real activity in the patients.18 For example to assess the lung shunt, the activity should be distributed uniformly in the lungs in these methods. Employing the simulation methods the real patient's SPECT/CT data could be used for this purpose.22, 23 We also documented that although the dose to the bone marrow is generally low, the unwanted radiation into the bone marrow is unexpectedly high and about twice of others in thin patients with low BMIs; this would be the condition of many patients candidate for 90Y‐microsphere injection because they have suffered long time of the underling malignant pathology and they received many courses of chemotherapy and external beam radiations and have concomitant malnutrition. The doses need adjustment in these patients and the benefit of the treatment versus the possibility of bone marrow suppression should be re‐evaluated before proceeding to therapy. In addition to the general radiation dependent side effects of 90Y‐microsphere including flu like syndrome and gastric ulceration, a more specific complication is radiation hepatitis. Post‐treatment liver absorbed dose may assist the clinician to make sophisticated decisions including creation of portosystemic shunts when hepatic failure is encountered after radioembolization. The other concern is radiation lung fibrosis due to lung shunting of the tracer. The extent of the lung shunting should be ascertained with injection of 99mTc‐MAA. In this study the radiation to the lungs with no shunt was studied. The radiation to the kidney, lungs and bone marrow was presented as the sample critical organs but any organ of concern could be added into this list easily. We found that the radiation in the kidney and lugs are reasonably lower than the dose limitation of 15 to 30 Gy.1 The absorbed dose in the bone marrow was negligible and below the threshold for even minor side effects (> 2 Gy).24 There are few data available for comparison. The radiation to the tumor in real intra‐arterial hepatic radioembolization was calculated to be about 76 Gy to the tumor by equation based calculation and 120–180 by MIRD approach which is comparable with the findings of the current study.25, 26 The safe dose to non‐tumoral liver parenchyma is considered less than 40 Gy.22 The radiation to the kidneys and lungs secondary to treatment with 90Y‐Zevalin in patients with lymphoma unresponsive to chemotherapy are equal and much higher than the estimated dose in our study respectively. The distribution of the Zevalin and Intra‐arterial hepatic radioembolization are different but the radiation dose to the lung and kidneys are comparably acceptable for the radioembolization.27 The major shortcoming of the current study is the lack of simulation with real patient's data in different dose, metastasis location and employed spheres.24 In fact the current data provoke us to precede the current simulation method in real clinical cases to consider enhancement of the future therapeutic administered doses.

Conclusion

We provided the data of the radiation dose into the liver and certain critical organs after 90Y‐microsphere therapy. The dose to the liver with conventional administered dose of 3 GBq is lower than the therapeutic target and the unwanted radiation to the other viscera is very low. However, particular concern in the thin patients may be amended before 90Y‐microsphere therapy to avoid bone marrow suppression, escalation of the administered dose may be used safely. The results should be confirmed in clinical setting.

Conflict of Interest

No conflict of interest exists in relation to this article.
  24 in total

Review 1.  Radioembolization for the treatment of liver tumors general principles.

Authors:  Andrew Kennedy; Douglas Coldwell; Bruno Sangro; Harpreet Wasan; Riad Salem
Journal:  Am J Clin Oncol       Date:  2012-02       Impact factor: 2.339

2.  Paired organs-should they be treated jointly or separately in internal dosimetry?

Authors:  Ali-Asghar Parach; Hossein Rajabi; Mohammad-Ali Askari
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

3.  Feasibility of 90Y TOF PET-based dosimetry in liver metastasis therapy using SIR-Spheres.

Authors:  Renaud Lhommel; Larry van Elmbt; Pierre Goffette; Marc Van den Eynde; François Jamar; Stanislas Pauwels; Stephan Walrand
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-04-27       Impact factor: 9.236

4.  MIRD pamphlet No. 21: a generalized schema for radiopharmaceutical dosimetry--standardization of nomenclature.

Authors:  Wesley E Bolch; Keith F Eckerman; George Sgouros; Stephen R Thomas
Journal:  J Nucl Med       Date:  2009-03       Impact factor: 10.057

Review 5.  Dosimetry of yttrium-labelled radiopharmaceuticals for internal therapy: 86Y or 90Y imaging?

Authors:  Stephan Walrand; Glenn D Flux; Mark W Konijnenberg; Roelf Valkema; Eric P Krenning; Renaud Lhommel; Stanislas Pauwels; Francois Jamar
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-03-11       Impact factor: 9.236

6.  Bremsstrahlung radiation dose in yttrium-90 therapy applications.

Authors:  M G Stabin; K F Eckerman; J C Ryman; L E Williams
Journal:  J Nucl Med       Date:  1994-08       Impact factor: 10.057

7.  4D XCAT phantom for multimodality imaging research.

Authors:  W P Segars; G Sturgeon; S Mendonca; Jason Grimes; B M W Tsui
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

8.  Patient-specific dosimetry of indium-111- and yttrium-90-labeled monoclonal antibody CC49.

Authors:  P K Leichner; G Akabani; D Colcher; K A Harrison; W G Hawkins; M Eckblade; J Baranowska-Kortylewicz; S C Augustine; J Wisecarver; M A Tempero
Journal:  J Nucl Med       Date:  1997-04       Impact factor: 10.057

9.  Radioembolisation with 90Y-microspheres: dosimetric and radiobiological investigation for multi-cycle treatment.

Authors:  Marta Cremonesi; Mahila Ferrari; Mirco Bartolomei; Franco Orsi; Guido Bonomo; Demetrio Aricò; Andrew Mallia; Concetta De Cicco; Guido Pedroli; Giovanni Paganelli
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-07-10       Impact factor: 9.236

10.  Treatment of inoperable hepatocellular carcinoma with intrahepatic arterial yttrium-90 microspheres: a phase I and II study.

Authors:  W Y Lau; W T Leung; S Ho; N W Leung; M Chan; J Lin; C Metreweli; P Johnson; A K Li
Journal:  Br J Cancer       Date:  1994-11       Impact factor: 7.640

View more
  1 in total

1.  A Chelate-Free Nano-Platform for Incorporation of Diagnostic and Therapeutic Isotopes.

Authors:  Yaser H Gholami; Lee Josephson; Eman A Akam; Peter Caravan; Moses Q Wilks; Xiang-Zuo Pan; Richard Maschmeyer; Aleksandra Kolnick; Georges El Fakhri; Marc D Normandin; Zdenka Kuncic; Hushan Yuan
Journal:  Int J Nanomedicine       Date:  2020-01-07
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.